The ACURATE neo2 valve system for transcatheter aortic valve implantation: 30-day and 1-year outcomes

被引:45
|
作者
Moellmann, Helge [1 ]
Holzhey, David M. [2 ]
Hilker, Michael [3 ]
Toggweiler, Stefan [4 ]
Schaefer, Ulrich [5 ]
Treede, Hendrik [6 ]
Joner, Michael [7 ,8 ]
Sondergaard, Lars [9 ]
Christen, Thomas [10 ]
Allocco, Dominic J. [10 ]
Kim, Won-Keun [11 ]
机构
[1] St Johannes Hosp Dortmund, Dept Internal Med 1, Johannesstr 9-13, D-44137 Dortmund, Germany
[2] Heart Ctr Leipzig, Dept Cardiovasc Surg, Leipzig, Germany
[3] Univ Regensburg, Klin Herz Thorax & Herznahe Gefasschirurg, Regensburg, Germany
[4] Luzerner Kantonsspital LUKS, Dept Cardiol, Luzern, Switzerland
[5] Marien Hosp, Ctr Internal Med, Hamburg, Germany
[6] Univ Hosp Mainz, Dept Cardiovasc Surg, Mainz, Germany
[7] Tech Univ Munich, Deutsch Herzzentrum Munchen, Munich, Germany
[8] DZHK German Ctr Cardiovasc Res, Munich Heart Alliance, Munich, Germany
[9] Rigshosp, Dept Cardiol, Copenhagen, Denmark
[10] Boston Sci, Marlborough, MA USA
[11] Kerckhoff Heart Ctr, Dept Cardiol, Cardiac Surg, Bad Nauheim, Germany
关键词
Aortic valve stenosis; Transcatheter aortic valve replacement; Transfemoral aortic valve implantation; Paravalvular regurgitation; REPLACEMENT; RISK; IMPACT; REGURGITATION; MULTICENTER; PROSTHESIS; MISMATCH;
D O I
10.1007/s00392-021-01882-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Transcatheter aortic valve implantation (TAVI) has become standard treatment for elderly patients with symptomatic severe aortic valve stenosis. The ACURATE neo AS study evaluates 30-day and 1-year clinical and hemodynamic outcomes in patients treated with the ACURATE neo2 valve. Methods The primary endpoint of this single-arm multicenter study is 30-day all-cause mortality. Other key endpoints include device performance, echocardiographic measures assessed by an independent core laboratory, and VARC-2 clinical efficacy and safety endpoints through 12 months. Results The study enrolled 120 patients (mean age 82.1 +/- 4.0 years; 67.5% female, mean baseline STS score 4.8 +/- 3.8%). The VARC-2 composite safety endpoint at 30 days occurred in 13.3% of patients. All-cause mortality was 3.3% at 30 days and 11.9% at 1 year. The 30-day stroke rate was 2.5% (disabling stroke 1.7%); there were no new strokes between 30 days and 12 months. The rate of permanent pacemaker implantation was 15.0% (18/120) at 30 days and 17.8% (21/120) at 1 year. No patients required re-intervention for valve-related dysfunction and there were no cases of valve thrombosis or endocarditis. Patients demonstrated significant improvement in mean aortic valve gradient (baseline 38.9 +/- 13.1 mmHg, 1 year 7.8 +/- 3.5 mmHg; P < 0.001 in a paired analysis). In the overall population, paravalvular leak was evaluated at 1 year as none/trace in 60.5%, mild in 37.0%, and moderate in 2.5%; no patients had severe PVL. Conclusions One-year outcomes from the ACURATE neo AS study support the safety and performance of TAVI with the ACURATE neo2 valve.
引用
收藏
页码:1912 / 1920
页数:9
相关论文
共 50 条
  • [1] The ACURATE neo2 valve system for transcatheter aortic valve implantation: 30-day and 1-year outcomes
    Helge Möllmann
    David M. Holzhey
    Michael Hilker
    Stefan Toggweiler
    Ulrich Schäfer
    Hendrik Treede
    Michael Joner
    Lars Søndergaard
    Thomas Christen
    Dominic J. Allocco
    Won-Keun Kim
    Clinical Research in Cardiology, 2021, 110 : 1912 - 1920
  • [2] ACURATE neo2 Transcatheter aortic valve implantation without balloon aortic valvuloplasty- direct ACURATE neo2
    Elkoumy, Ahmed
    Ruck, Andreas
    Abdel-Wahab, Mohamed
    Thiele, Holger
    Rudolph, Tanja K.
    Wolf, Alexander
    Wambach, Jan Martin
    De Backer, Ole
    Sondergaard, Lars
    Hengstenberg, Christian
    Abdelshafy, Mahmoud
    Arsang-Jang, Shahram
    Elzomor, Hesham
    Laine, Mika
    Bjursten, Henrik
    Gotberg, Matthias
    Wykrzykowska, Joanna J.
    Mohamed, Sameh K.
    Pellegrini, Costanza
    Rheude, Tobias
    Toggweiler, Stefan
    Saleh, Nawzad
    Meduri, Christopher U.
    Kim, Won-Keun
    Soliman, Osama
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2024, 400
  • [3] The Early neo2 Registry: Transcatheter Aortic Valve Implantation With ACURATE neo2 in a European Population
    Rueck, Andreas
    Kim, Won-Keun
    Abdel-Wahab, Mohamed
    Thiele, Holger
    Rudolph, Tanja K.
    Wolf, Alexander
    Wambach, Jan Martin
    De Backer, Ole
    Sondergaard, Lars
    Hengstenberg, Christian
    Laine, Mika
    Miyashita, Hirokazu
    Bjursten, Henrik
    Goetberg, Matthias
    Pellegrini, Costanza
    Toggweiler, Stefan
    Wykrzykowska, Joanna J.
    Soliman, Osama
    Saleh, Nawzad
    Meduri, Christopher U.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2023, 12 (15):
  • [4] Paravalvular Leak After Implantation of the ACURATE neo and the ACURATE neo2 Transcatheter Heart Valve
    Toggweiler, Stefan
    Brinkert, Miriam
    Wolfrum, Mathias
    Moccetti, Federico
    Stampfli, Simon F.
    De Boeck, Bart W. L.
    Magarzo, Getulio
    Gassenmaier, Tobias
    Attinger-Toller, Adrian
    Bossard, Matthias
    Fornaro, Jurgen
    Buhmann, Ralf
    Cuculi, Florim
    Kobza, Richard
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2022, 45 : 37 - 43
  • [5] Commissural alignment and the ACURATE neo2 transcatheter aortic valve: Impact on valve performance
    Travieso, Alejandro
    Toggweiler, Stefan
    Montarello, Nicholas
    Renker, Matthias
    Tirado-Conte, Gabriela
    Loretz, Lucca
    Charitos, Efstratios I.
    Kim, Won-Keun
    De Backer, Ole
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2024, 104 (01) : 115 - 124
  • [6] Technical Considerations for Transcatheter Aortic Valve Replacement With ACURATE neo2
    Wong, Ivan
    Bieliauskas, Gintautas
    De Backer, Ole
    Sondergaard, Lars
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (02) : 224 - 226
  • [7] Paravalvular Aortic Regurgitation Severity Assessed by Quantitative Aortography: ACURATE neo2 versus ACURATE neo Transcatheter Aortic Valve Implantation
    Ruck, Andreas
    Kim, Won-Keun
    Kawashima, Hideyuki
    Abdelshafy, Mahmoud
    Elkoumy, Ahmed
    Elzomor, Hesham
    Wang, Rutao
    Meduri, Christopher U.
    Verouhis, Dinos
    Saleh, Nawzad
    Onuma, Yoshinobu
    Mylotte, Darren
    Serruys, Patrick W.
    Soliman, Osama
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (20)
  • [8] Next-Day Discharge After Transcatheter Aortic Valve Implantation With the ACURATE neo/neo2 Self-Expanding Aortic Bioprosthesis
    Ordonez, Santiago
    Chu, Michael W. A.
    Diamantouros, Pantelis
    Valdis, Matthew
    Chaumont, Gloria
    Vila, Rocio Consuelo Baro
    Teefy, Patrick
    Bagur, Rodrigo
    AMERICAN JOURNAL OF CARDIOLOGY, 2024, 227 : 65 - 74
  • [9] Hypoattenuated Leaflet Thickening After Implantation of the ACURATE neo or the ACURATE neo2 Transcatheter Heart Valve
    Brunner, Stephanie
    Brinkert, Miriam
    Moccetti, Federico
    Loretz, Lucca
    Fornaro, Jurgen
    Stampfli, Simon F.
    Attinger-Toller, Adrian
    Bossard, Matthias
    Buhmann, Ralf
    Cuculi, Florim
    Wolfrum, Mathias
    Toggweiler, Stefan
    AMERICAN JOURNAL OF CARDIOLOGY, 2023, 200 : 146 - 152
  • [10] Transcatheter Aortic Valve Replacement With Self-Expanding Acurate Neo2 Valve Versus Acurate Neo Valve: A Meta-Analysis
    Aggarwal, Gaurav
    Haddad, Toufik Mahfood
    Bansal, Sakshi
    Aggarwal, Saurabh
    Umeh, Chikwuemeka
    Gokhroo, Rahul
    Agarwal, Himanshu
    Narmi, Ann E.
    Reddy, Arun Kanmantha
    DelCore, Michael G.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (04) : S88 - S89