Commissural alignment and the ACURATE neo2 transcatheter aortic valve: Impact on valve performance

被引:0
|
作者
Travieso, Alejandro [1 ]
Toggweiler, Stefan [2 ]
Montarello, Nicholas [1 ]
Renker, Matthias [3 ,4 ,5 ]
Tirado-Conte, Gabriela [1 ]
Loretz, Lucca [2 ]
Charitos, Efstratios I. [3 ]
Kim, Won-Keun [3 ,4 ,5 ,6 ]
De Backer, Ole [1 ]
机构
[1] Rigshosp, Heart Ctr, Inge Lehmannsvej 7, DK-2100 Copenhagen, Denmark
[2] Lucerner Kantonsspital, Heart Ctr Lucerne, Luzern, Switzerland
[3] Kerckhoff Heart Ctr, Dept Cardiol, Bad Nauheim, Germany
[4] Kerckhoff Heart Ctr, Dept Cardiac Surg, Bad Nauheim, Germany
[5] German Ctr Cardiovasc Res, Site Rhein Main, Bad Nauheim, Germany
[6] Justus Liebig Univ Giessen & Marburg, Dept Cardiol, Giessen, Germany
关键词
aortic regurgitation; commissural alignment; patient-prosthesis mismatch; transcatheter aortic valve replacement; valve performance; REPLACEMENT;
D O I
10.1002/ccd.31089
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Transcatheter aortic valve replacement (TAVR) is increasingly being used to treat severe aortic stenosis in younger patients. Accordingly, lifetime management regarding future reintervention and coronary access is a concern. Aims: To assess the impact of commissural alignment on ACURATE neo2 transcatheter aortic valve (TAV) performance. Methods: COMALIGN-neo2 was an observational, retrospective study enrolling consecutive TAVR patients treated with the ACURATE neo2 (October 2021 to October 2022). The degree of commissural (mis)-alignment (CMA) with the native aortic valve commissures was determined and transvalvular gradient, effective orifice area, patient-prosthesis mismatch (PPM), and aortic regurgitation (AR) were assessed. Results: Among 825 patients, the mean age was 80.7 years and 42% were female. Commissural alignment was achieved in 60% of cases; mild (26%), moderate (9%), and severe misalignment (5%) were found less often. Severe PPM occurred more frequently in patients with severe CMA (14.7%) compared to aligned valves (p = 0.034). By multivariate analysis, severe CMA (odds ratio [OR]: 3.12, 95% confidence interval [CI] [1.09-8.90]; p = 0.033) and lack of postdilatation (OR: 3.85, [1.33-11.1]; p = 0.012) were associated with severe PPM. Higher rates of >= mild AR (51.4%) were found in TAVs implanted with severe CMA compared to aligned (34.3%), mildly (38.1%) or moderately (36.0%) misaligned TAVs (p = 0.030). Multivariate analysis identified severe CMA (OR: 2.05, [1.05-4.02]; p = 0.037) to be an independent predictor of >= mild AR. Conclusions: COMALIGN-neo2 is the largest study to date assessing the impact of commissural alignment on acute TAV performance. Severe CMA with the ACURATE neo2 platform was associated with worse valve hemodynamics and increased risk for mild AR.
引用
收藏
页码:115 / 124
页数:10
相关论文
共 50 条
  • [1] Commissural Alignment With ACURATE neo2 Valve in an Unselected Population
    Meduri, Christopher U.
    Ruck, Andreas
    Linder, Rickard
    Verouhis, Dinos
    Settergren, Magnus
    Sorajja, Amalin
    Daher, Daniel
    Saleh, Nawzad
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (06) : 670 - 677
  • [2] Neo-Commissural Alignment Technique for Transcatheter Aortic Valve Replacement Using the ACURATE Neo Valve
    Abdel-Wahab, Mohamed
    Kitamura, Mitsunobu
    Fitzgerald, Sean J.
    Dumpies, Oliver
    Wilde, Johannes
    Gohmann, Robin F.
    Majunke, Nicolas
    Gutberlet, Matthias
    Kiefer, Philipp
    Noack, Thilo
    Lurz, Philipp
    Desch, Steffen
    Frawley, Christopher
    Ward, Kevin
    Borger, Michael A.
    Holzhey, David
    Thiele, Holger
    [J]. CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (07) : 632 - 634
  • [3] Commissural Alignment of the ACURATE neo Aortic Valve Replacement
    Kitamura, Mitsunobu
    Wilde, Johannes
    Gohmann, Robin
    Majunke, Nicolas
    Gutberlet, Matthias
    Shibata, Masafumi
    Kiefer, Philipp
    Desch, Steffen
    Thiele, Holger
    Holzhey, David
    Abdel-Wahab, Mohamed
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (15) : 1740 - 1742
  • [4] ACURATE neo2 Transcatheter aortic valve implantation without balloon aortic valvuloplasty- direct ACURATE neo2
    Elkoumy, Ahmed
    Ruck, Andreas
    Abdel-Wahab, Mohamed
    Thiele, Holger
    Rudolph, Tanja K.
    Wolf, Alexander
    Wambach, Jan Martin
    De Backer, Ole
    Sondergaard, Lars
    Hengstenberg, Christian
    Abdelshafy, Mahmoud
    Arsang-Jang, Shahram
    Elzomor, Hesham
    Laine, Mika
    Bjursten, Henrik
    Gotberg, Matthias
    Wykrzykowska, Joanna J.
    Mohamed, Sameh K.
    Pellegrini, Costanza
    Rheude, Tobias
    Toggweiler, Stefan
    Saleh, Nawzad
    Meduri, Christopher U.
    Kim, Won-Keun
    Soliman, Osama
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2024, 400
  • [5] Technical Considerations for Transcatheter Aortic Valve Replacement With ACURATE neo2
    Wong, Ivan
    Bieliauskas, Gintautas
    De Backer, Ole
    Sondergaard, Lars
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (02) : 224 - 226
  • [6] Transcatheter Aortic Valve Replacement With Self-Expanding Acurate Neo2 Valve Versus Acurate Neo Valve: A Meta-Analysis
    Aggarwal, Gaurav
    Haddad, Toufik Mahfood
    Bansal, Sakshi
    Aggarwal, Saurabh
    Umeh, Chikwuemeka
    Gokhroo, Rahul
    Agarwal, Himanshu
    Narmi, Ann E.
    Reddy, Arun Kanmantha
    DelCore, Michael G.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (04) : S88 - S89
  • [7] The Early neo2 Registry: Transcatheter Aortic Valve Implantation With ACURATE neo2 in a European Population
    Rueck, Andreas
    Kim, Won-Keun
    Abdel-Wahab, Mohamed
    Thiele, Holger
    Rudolph, Tanja K.
    Wolf, Alexander
    Wambach, Jan Martin
    De Backer, Ole
    Sondergaard, Lars
    Hengstenberg, Christian
    Laine, Mika
    Miyashita, Hirokazu
    Bjursten, Henrik
    Goetberg, Matthias
    Pellegrini, Costanza
    Toggweiler, Stefan
    Wykrzykowska, Joanna J.
    Soliman, Osama
    Saleh, Nawzad
    Meduri, Christopher U.
    [J]. JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2023, 12 (15):
  • [8] ACURATE neo2 versus SAPIEN 3 Ultra for transcatheter aortic valve
    Pellegrini, Costanza
    Rheude, Tobias
    Renker, Matthias
    Wolf, Alexander
    Wambach, Jan Martin
    Alvarez-Covarrubias, Hector A.
    Doerr, Oliver
    Singh, Parminder
    Charitos, Efstratios, I
    Xhepa, Erion
    Joner, Michael
    Kim, Won-Keun
    [J]. EUROINTERVENTION, 2023, 18 (12) : 987 - +
  • [9] The ACURATE neo™ and neo2™ Valve Systems
    Reardon, Michael J.
    [J]. HEART INTERNATIONAL, 2021, 15 (01): : 37 - 41
  • [10] Paravalvular Leak After Implantation of the ACURATE neo and the ACURATE neo2 Transcatheter Heart Valve
    Toggweiler, Stefan
    Brinkert, Miriam
    Wolfrum, Mathias
    Moccetti, Federico
    Stampfli, Simon F.
    De Boeck, Bart W. L.
    Magarzo, Getulio
    Gassenmaier, Tobias
    Attinger-Toller, Adrian
    Bossard, Matthias
    Fornaro, Jurgen
    Buhmann, Ralf
    Cuculi, Florim
    Kobza, Richard
    [J]. CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2022, 45 : 37 - 43