Lightning Protection of A 22kV Distribution Overhead Line- A Case Study

被引:0
|
作者
Khuluse, P. N. [1 ]
Nnachi, A. F. [1 ]
Moloi, K. [1 ]
Akumu, A. O. [1 ]
机构
[1] Tshwane Univ Technol, Dept Elect Engn, eMalahleni Campus, Emalahleni, South Africa
关键词
Distribution Systems; Surge arrestors; Steamers; Lightning;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The protection of electrical distribution network against lightning with high reliability is a critical aspect for power utilities. Lightning strokes influences the performance of a distribution systems. In this paper, we investigate the option of using streamer to minimize the effect of lightning in the Doulas MMS Coal 22kV plant. The network is modelled using MATLAB. Furthermore, we compared the surge arrestors and streamers and determined a suitable option for the application.
引用
收藏
页码:792 / 796
页数:5
相关论文
共 50 条
  • [41] Observation on improved 20 kV's overhead distribution lines against lightning
    Zoro, R.
    Mefiardhi, R.
    Aritonang, R. R.
    Suhana, H.
    ICPASM 2005: PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 2006, : 979 - +
  • [42] The Method and Recommended Guidelines of Lightning Protection Design for Urban Rail Overhead Line
    Wang, Litian
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON ELECTRICAL AND INFORMATION TECHNOLOGIES FOR RAIL TRANSPORTATION: ELECTRICAL TRACTION, 2016, 377 : 737 - 758
  • [43] The Calculation Method of Lightning Protection Design of Overhead Line in Urban Rail Transit
    Wang, Litian
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON ELECTRICAL AND INFORMATION TECHNOLOGIES FOR RAIL TRANSPORTATION: ELECTRICAL TRACTION, 2016, 377 : 723 - 736
  • [44] Lightning protection of a multi-circuit HV-MV overhead line
    Borghetti, Alberto
    Figueiredo Ferraz, Guilherme Martinez
    Napolitano, Fabio
    Nucci, Carlo Alberto
    Piantini, Alexandre
    Tossani, Fabio
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 180
  • [45] Study on Lightning Withstand Level and Protection Measures of 10kV Distribution Lines
    Yang, Xibin
    Qiu, Xudong
    Liu, Hao
    Chen, Changfu
    Han, Yongxia
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 3626 - 3631
  • [46] Investigation study for double circuit lightning trip incident at 275kV overhead line network in Malaysia
    Chia, H. K.
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 1740 - 1745
  • [47] The effect of sandy soil porosity on lightning overvoltages of overhead 138 kV transmission line
    de Azevedo, Walter Luiz Manzi
    de Araujo, Anderson Ricardo Justo
    Pissolato Filho, Jose
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 220
  • [48] Analysis of Overvoltages in a 110 kV/MV Substation as a Result of Lightning Discharges to the Overhead Line
    Benesz, Mariusz
    Bachorek, Wojciech
    2019 PROGRESS IN APPLIED ELECTRICAL ENGINEERING (PAEE), 2019,
  • [49] A Stochastic Model for Evaluating the Lightning Performance of a-400 kV HVDC Overhead Line
    Datsios, Zacharias G.
    Ioannidis, Alexios I.
    Papadopoulos, Theofilos A.
    Tsovilis, Thomas E.
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2021, 63 (05) : 1433 - 1443
  • [50] Lightning Performance of 70 kV Overhead-Line Sub-Transmission in Bandung
    Prasetyo, Eko
    Silaen, Nelson
    Arif, Abghi Ilman
    Merta, I. Made Sugata
    2022 IEEE PES 14TH ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE, APPEEC, 2022,