The initial stability and contact mechanics of a press-fit resurfacing arthroplasty of the hip

被引:45
|
作者
Udofia, I.
Liu, F.
Jin, Z.
Roberts, P.
Grigoris, P.
机构
[1] Univ Leeds, Inst Med & Biol Engn, Sch Mech Engn, Leeds LS2 9JT, W Yorkshire, England
[2] Royal Gwent Hosp, Newport NP20 2UB, Gwent, Wales
[3] Univ Bradford, Sch Engn Design & Technol, Bradford BD7 1DP, W Yorkshire, England
来源
关键词
D O I
10.1302/0301-620X.89B4.18055
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Finite element analysis was used to examine the initial stability after hip resurfacing and the effect of the procedure on the contact mechanics at the articulating surfaces. Models were created with the components positioned anatomically and loaded physiologically through major muscle forces. Total micromovement of less than 10 mu m was predicted for the press-fit acetabular components models, much below the 50 mu m limit required to encourage osseointegration. Relatively high compressive acetabular and contact stresses were observed in these models. The press-fit procedure showed a moderate influence on the contact mechanics at the bearing surfaces, but produced marked deformation of the acetabular components. No edge contact was predicted for the acetabular components studied. It is concluded that the frictional compressive stresses generated by the 1 mm to 2 mm interference-fit acetabular components, together with the minimal micromovement, would provide adequate stability for the implant, at least in the immediate post-operative situation.
引用
收藏
页码:549 / 556
页数:8
相关论文
共 50 条
  • [31] Acetabular revision in total hip replacement with a press-fit cup
    Elke, R
    Berli, B
    Wagner, A
    Morscher, EW
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (08): : 1114 - 1119
  • [32] Assessment of press-fit hip femoral components retrieved at autopsy
    Lester, DK
    Campbell, P
    Ehya, A
    Rude, RK
    ORTHOPEDICS, 1998, 21 (01) : 27 - 33
  • [33] PRESS FIT IMPLANT ARTHROPLASTY OF HIP AND KNEE
    SBARBARO, JL
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1974, 8 (04): : 285 - 288
  • [34] Patella Strength Characteristics in Cemented vs Press-fit Implants: A Biomechanical Analysis of Initial Stability
    Patel, Akshar H.
    Wilder, J. Heath
    Weldy, John M.
    Ross, Bailey J.
    Kim, Nathaniel E.
    Wang, Hao
    Sanchez, Fernando L.
    Sherman, William F.
    ARTHROPLASTY TODAY, 2022, 14 : 140 - 147
  • [35] Initial stability of press-fit acetabular cups. In vitro lever-out trials
    Kuhn, A
    Scheller, G
    Schwarz, M
    BIOMEDIZINISCHE TECHNIK, 1999, 44 (12): : 356 - 359
  • [36] Effect of interposed tissue and contamination on the initial stability of a highly porous press-fit acetabular cup
    Wiznia, Daniel H.
    Joyal, Garrett
    Schmidig, Gregg
    Rajaravivarma, Raga
    Lokesh, Raja
    Schwartzkopf, Ran
    Iorio, Richard
    Long, William J.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2019, 37 (05) : 1117 - 1122
  • [37] Limitation of total hip arthroplasty of the acetabular roof by press-fit without screw fixation: Discussion of a biomechanical study
    Kanda A.
    Kaneko K.
    Obayashi O.
    Mogami A.
    Iwase H.
    European Journal of Orthopaedic Surgery & Traumatology, 2013, 23 (4) : 417 - 424
  • [38] Revision Total Hip Arthroplasty Using a Tapered, Press-Fit Cement less Revision Stem in Elderly Patients
    Chang, Jun-Dong
    Kim, Tae-Young
    Rao, Murari Bhaskar
    Lee, Sang-Soo
    Kim, In-Sung
    JOURNAL OF ARTHROPLASTY, 2011, 26 (07): : 1045 - 1049
  • [39] Survival analysis of cemented press-fit condylar total knee arthroplasty
    Khaw, FM
    Kirk, LMG
    Gregg, PJ
    JOURNAL OF ARTHROPLASTY, 2001, 16 (02): : 161 - 167
  • [40] Outcomes and radiographic findings of anatomic press-fit radial head arthroplasty
    Levy, Jonathan C.
    Formaini, Nathan T.
    Kurowicki, Jennifer
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (05) : 802 - 809