Transient supercooling performance of thermoelectric coolers with a continuous double current pulse

被引:20
|
作者
Wang, Shuo-Lin [1 ,2 ]
Liu, Hai-Bo [1 ,2 ]
Gao, Yan-Wei [3 ]
Shen, Yuan [1 ,2 ]
Yang, Yan-Ru [1 ,2 ]
Wang, Xiao-Dong [1 ,2 ]
Lee, Duu-Jong [4 ,5 ]
机构
[1] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewabl, Beijing 102206, Peoples R China
[2] North China Elect Power Univ, Res Ctr Engn Thermophys, Beijing 102206, Peoples R China
[3] China Acad Safety Sci & Technol, Beijing Key Lab Metro Fire & Passenger Transporta, Beijing 100012, Peoples R China
[4] Natl Taiwan Univ, Dept Chem Engn, Taipei 106, Taiwan
[5] City Univ Hong Kong, Dept Mech Engn, Kowloon, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Thermoelectric cooler; Transient supercooling; Cooling; Holding time; Numerical simulations; THERMAL-BEHAVIOR; MODEL; OPERATION; DESIGN; MODULE;
D O I
10.1016/j.jtice.2021.02.030
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this work, the transient supercooling performance of thermoelectric coolers is numerically investigated via a three-dimensional, multiphysics, and transient model. The particular focus is placed on how to increase the holding time of supercooling state to meet some specific cooling requirements. A new concept of effective cooling temperature line is proposed to evaluate the supercooling performance. On the basis of this concept, the frequently used holding time of supercooling state is replaced by an effective holding time, t(eff-hold). As a reference baseline, the transient supercooling performance is first evaluated under a single current pulse and the largest t(eff-hold) is determined by searching for the optimal pulse width and amplitude. Subsequently, the supercooling performance and the effective holding time are evaluated under a continuous double current pulse whose shape can be characterized by the pulse width (tau(1)) and amplitude (P1) of the first pulse, the pulse width (tau(2)) and amplitude (P-2) of the second pulse, and the initial current (Iini,2) of the second pulse. The results show that among the five parameters I-ini,I-2 is the most dominant parameter to achieve a larger teff-hold. Only when Iini, 2 is higher than the initial current of the first pulse, employing a double pulse can yield a larger t(eff-hold) than employing the optimal single pulse. The results also demonstrate that with a proper I-ini,I-2 the value of t(eff-hold) can be further prolonged by optimizing tau(1), tau(2), P-1, and P-2, and the largest t(eff-hold) for the optimal double pulse is increased by 59.8%, as compared with that of the optimal single pulse. Finally, the principles for selecting parameters of a double current pulse are discussed. (c) 2021 Taiwan Institute of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:127 / 135
页数:9
相关论文
共 50 条
  • [41] Fabrication and performance of pulse-current sintered Si-Ge thermoelectric couples
    Otake, M
    Sato, K
    Sugiyama, O
    Kaneko, S
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2005, 152 (11) : A2148 - A2150
  • [42] Transient Cooling of Power Electronic Devices using Thermoelectric Coolers coupled with Phase Change Materials
    Caroff, T.
    Mitova, R.
    Wunderle, B.
    Simon, J.
    2013 19TH INTERNATIONAL WORKSHOP ON THERMAL INVESTIGATIONS OF ICS AND SYSTEMS (THERMINIC), 2013, : 262 - 267
  • [43] Effect of wall airflow restriction on heat-sink performance with thermoelectric coolers
    Lau, PG
    Ritzer, TM
    ICT: 2005 24th International Conference on Thermoelectrics, 2005, : 61 - 63
  • [44] A Comparison of Performance Characteristics of Multistage Thermoelectric Coolers Based on Different Ceramic Substrates
    Semenyuk, V.
    JOURNAL OF ELECTRONIC MATERIALS, 2014, 43 (06) : 1539 - 1547
  • [45] Comprehensive Performance Analysis of Thermoelectric Coolers Based on Heat Pipe Heat Dissipation
    Meng F.
    Chen Z.
    Xu C.
    Jiang F.
    Xie Z.
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2021, 49 (10): : 104 - 113
  • [46] Effect of buckling on the cooling performance of free-standing planar thermoelectric coolers
    Cui, Y. J.
    Wang, K. F.
    Wang, B. L.
    Zheng, L.
    JOURNAL OF THERMAL STRESSES, 2019, 42 (08) : 962 - 975
  • [47] A Comparison of Performance Characteristics of Multistage Thermoelectric Coolers Based on Different Ceramic Substrates
    V. Semenyuk
    Journal of Electronic Materials, 2014, 43 : 1539 - 1547
  • [48] CONTINUOUS DISCHARGE IMPROVES THE PERFORMANCE OF THE CU-CUCL DOUBLE PULSE LASER
    KUSHNER, MJ
    CULICK, FEC
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1979, 15 (09) : 835 - 837
  • [49] Performance of the airs pulse tube coolers and instrument - a first year in space
    Ross, RG
    Rodriguez, JI
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS. 49A AND B, 2004, 710 : 1293 - 1300
  • [50] A model for the performance assessment of hybrid coolers by means of transient numerical simulation
    D'Antoni, M.
    Romeli, D.
    Fedrizzi, R.
    APPLIED ENERGY, 2016, 181 : 477 - 494