Phase Current Reconstruction for the Grid-Sae Converter With Four-Switch Three-Phase Topology in a DFIG-WT

被引:4
|
作者
Ni, Kai [1 ]
Li, Wei [2 ]
Liu, Yang [3 ]
Yu, Dongsheng [4 ]
Hu, Yihua [1 ]
机构
[1] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3GJ, Merseyside, England
[2] State Grid Int Dev Co Ltd, Beijing 100031, Peoples R China
[3] South China Univ Technol, Sch Elect Power Engn, Guangzhou 510640, Guangdong, Peoples R China
[4] China Univ Min & Technol, Sch Elect & Power Engn, Xuzhou 221116, Jiangsu, Peoples R China
来源
IEEE ACCESS | 2018年 / 6卷
基金
中国博士后科学基金;
关键词
Reliability; doubly-fed induction generator-based wind turbine; grid-side converter; four-switch three-phase; phase current reconstruction; space vector pulse width modulation; SINGLE CURRENT SENSOR; DC-LINK CURRENT; INVERTERS; DRIVE; INJECTION; SCHEME; DTC;
D O I
10.1109/ACCESS.2018.2853761
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
To increase the reliability of a doubly fed induction generator-based wind turbine (DFIG-WT), this paper proposes a fault-tolerant four-switch three-phase (FSTP) grid-side converter (GSC) with a phase current reconstruction strategy. The proposed strategy is effective when the semiconductor open-circuit fault and phase current sensor failure occur simultaneously, which is a kind of hybrid fault. Only one current sensor is applied for measuring the currents flowing between the ac and dc sides of the GSC, and the phase current information can be derived by combining this information with the switching states of FSTP GSC. In the proposed current reconstruction strategy, only two scenarios of duty ratio allocation are needed to be considered. In addition, the space vector pulsewidth modulation (SVPWM) technique is simplified by obtaining the unified expressions for the duty ratios for the remaining four switches in GSC, and the sector identification is removed. Besides, the voltage balancing on the dc bus is achieved. Furthermore, the limitation of the proposed current reconstruction strategy is presented, and the dead zones for SVPWM techniques in both six-switch three-phase and FSTP converters are analyzed. Simulations are carried out in MATLAB/Simulink to verify the proposed hybrid fault-tolerant strategy for the GSC in a 1.5-MW DFIG-WT.
引用
收藏
页码:39287 / 39297
页数:11
相关论文
共 50 条
  • [21] Advanced Vector Controller for a Four-Switch Three-Phase Rectifier under Unbalanced Grid Voltage
    Bidgoli, M. Alizadeh
    Honarbari, S.
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2022, 2022
  • [22] A Zeta-Converter Based Four-Switch Three-Phase DC-AC Inverter
    Diab, M. S.
    Elserougi, A.
    Abdel-Khalik, A. S.
    Massoud, A. M.
    Ahmed, Shehab
    2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2015, : 4671 - 4677
  • [23] Four-switch three-phase space-vector PWM AC-DC converter
    Klima, J.
    Skramlik, J.
    Valouch, V.
    INTERNATIONAL JOURNAL OF ELECTRONICS, 2008, 95 (04) : 383 - 397
  • [24] Three-Phase Four-Switch Converter for SPMS Generators Based on Model Predictive Current Control for Wave Energy Applications
    Ebrahim Zarei, Mohammad
    Ramirez, Dionisio
    Veganzones Nicolas, Carlos
    Rodriguez Arribas, Jaime
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (01) : 289 - 302
  • [25] General SVPWM strategy for three different four-switch three-phase inverters
    Liu, Yong-Chao
    Ge, Xing-Lai
    Zhang, Jie
    Feng, Xiao-Yun
    ELECTRONICS LETTERS, 2015, 51 (04) : 357 - 358
  • [26] Sector determination for SVPWM based four-switch three-phase VSI
    Kivanc, O. C.
    Ozturk, S. B.
    ELECTRONICS LETTERS, 2017, 53 (05) : 343 - 344
  • [27] A Current Control Scheme of Brushless DC Motors Driven by Four-Switch Three-Phase Inverters
    Xia, Changliang
    Wu, Dan
    Shi, Tingna
    Wei, Chen
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2017, 5 (01) : 547 - 558
  • [28] Three-Phase Four-Switch Partial Resonant Soft Switched Rectifier
    De, Ankan
    Bhattacharya, Subhashish
    2014 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2014, : 1022 - 1028
  • [29] Eliminating output distortion in four-switch inverters with three-phase loads
    Peters, GL
    Covic, GA
    Boys, JT
    IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 1998, 145 (04): : 326 - 332
  • [30] Novel, Four-Switch, Z-Source Three-Phase Inverter
    Antal, Robert
    Muntean, Nicolae
    Boldea, Ion
    Blaabjerg, Frede
    IECON 2010: 36TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2010,