Phase Current Reconstruction for the Grid-Sae Converter With Four-Switch Three-Phase Topology in a DFIG-WT

被引:4
|
作者
Ni, Kai [1 ]
Li, Wei [2 ]
Liu, Yang [3 ]
Yu, Dongsheng [4 ]
Hu, Yihua [1 ]
机构
[1] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3GJ, Merseyside, England
[2] State Grid Int Dev Co Ltd, Beijing 100031, Peoples R China
[3] South China Univ Technol, Sch Elect Power Engn, Guangzhou 510640, Guangdong, Peoples R China
[4] China Univ Min & Technol, Sch Elect & Power Engn, Xuzhou 221116, Jiangsu, Peoples R China
来源
IEEE ACCESS | 2018年 / 6卷
基金
中国博士后科学基金;
关键词
Reliability; doubly-fed induction generator-based wind turbine; grid-side converter; four-switch three-phase; phase current reconstruction; space vector pulse width modulation; SINGLE CURRENT SENSOR; DC-LINK CURRENT; INVERTERS; DRIVE; INJECTION; SCHEME; DTC;
D O I
10.1109/ACCESS.2018.2853761
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
To increase the reliability of a doubly fed induction generator-based wind turbine (DFIG-WT), this paper proposes a fault-tolerant four-switch three-phase (FSTP) grid-side converter (GSC) with a phase current reconstruction strategy. The proposed strategy is effective when the semiconductor open-circuit fault and phase current sensor failure occur simultaneously, which is a kind of hybrid fault. Only one current sensor is applied for measuring the currents flowing between the ac and dc sides of the GSC, and the phase current information can be derived by combining this information with the switching states of FSTP GSC. In the proposed current reconstruction strategy, only two scenarios of duty ratio allocation are needed to be considered. In addition, the space vector pulsewidth modulation (SVPWM) technique is simplified by obtaining the unified expressions for the duty ratios for the remaining four switches in GSC, and the sector identification is removed. Besides, the voltage balancing on the dc bus is achieved. Furthermore, the limitation of the proposed current reconstruction strategy is presented, and the dead zones for SVPWM techniques in both six-switch three-phase and FSTP converters are analyzed. Simulations are carried out in MATLAB/Simulink to verify the proposed hybrid fault-tolerant strategy for the GSC in a 1.5-MW DFIG-WT.
引用
收藏
页码:39287 / 39297
页数:11
相关论文
共 50 条
  • [1] Rotor-Side Converter Reconfiguration Using Four-Switch Three-Phase Topology in DFIG-WT for Fault-Tolerant Purpose
    Ni, Kai
    Hu, Yihua
    Liu, Yang
    Yu, Dongsheng
    2017 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO, ASIA-PACIFIC (ITEC ASIA-PACIFIC), 2017, : 1015 - 1020
  • [2] Fault-Tolerant Operation of DFIG-WT With Four-Switch Three-Phase Grid-Side Converter by Applying A Simplified SVPWM Technique
    Ni, Kai
    Hu, Yihua
    Liu, Yang
    Gan, Chun
    2017 IEEE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE (IEMDC), 2017,
  • [3] Fault-Tolerant Operation of DFIG-WT With Four-Switch Three-Phase Grid-Side Converter by Using Simplified SVPWM Technique and Compensation Schemes
    Ni, Kai
    Hu, Yihua
    Chen, Guipeng
    Gan, Chun
    Li, Xinhua
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (01) : 659 - 669
  • [4] Using of four-switch three-phase converter in the structure DPC of DFIG under unbalanced grid voltage condition
    Ali Izanlo
    S. Asghar Gholamian
    Mohammad Verij Kazemi
    Electrical Engineering, 2018, 100 : 1925 - 1938
  • [5] Using of four-switch three-phase converter in the structure DPC of DFIG under unbalanced grid voltage condition
    Izanlo, Ali
    Gholamian, S. Asghar
    Kazemi, Mohammad Verij
    ELECTRICAL ENGINEERING, 2018, 100 (03) : 1925 - 1938
  • [6] Design and Implementation of Four-Switch Current Sensorless Control for Three-Phase PFC Converter
    Li, Chung-Yi
    Chao, Nan-Chih
    Chen, Hung-Chi
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2020, 67 (04) : 3307 - 3312
  • [7] Performance Analysis of a Four-Switch Three-Phase Grid-Side Converter with Modulation Simplification in a Doubly-Fed Induction Generator-Based Wind Turbine (DFIG-WT) with Different External Disturbances
    Ni, Kai
    Hu, Yihua
    Liu, Yang
    Gan, Chun
    ENERGIES, 2017, 10 (05):
  • [8] Analytical Closed-Form Solution of Current Responses of Four-Switch Converter Connected to Three-Phase Unbalanced Grid
    Valouch, Viktor
    Simek, Petr
    Skramlik, Jiri
    2015 INTERNATIONAL CONFERENCE ON ELECTRICAL DRIVES AND POWER ELECTRONICS (EDPE), 2015, : 25 - 29
  • [9] A Four-Switch Three-Phase AC-DC Converter With Galvanic Isolation
    Khodabakhsh, Javad
    Moschopoulos, Gerry
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (02) : 1699 - 1710
  • [10] A Four-Switch Three-Phase AC-DC Converter with Galvanic Isolation
    Khodabakhsh, Javad
    Moschopoulos, Gerry
    THIRTY-THIRD ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2018), 2018, : 37 - 43