Corneal imaging with slit-scanning and Scheimpflug imaging techniques

被引:77
|
作者
Oliveira, Cristina M. [1 ]
Ribeiro, Celina [1 ]
Franco, Sandra [1 ]
机构
[1] Univ Minho, Ctr Dept Phys, Braga, Portugal
关键词
corneal imaging; keratoconus; keratorefractive surgery; rotating Scheimpflug tomography; slit‐ scanning tomography system; IN-SITU KERATOMILEUSIS; NONCONTACT SPECULAR MICROSCOPY; OPTICAL COHERENCE TOMOGRAPHY; INTRAOCULAR-LENS CALCULATION; LASER REFRACTIVE SURGERY; THICKNESS MEASUREMENTS; ORBSCAN-II; ULTRASOUND PACHYMETRY; KERATOMETRY READINGS; KERATOCONIC EYES;
D O I
10.1111/j.1444-0938.2010.00509.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Modern anterior segment imaging techniques, such as slit-scanning and Scheimpflug imaging, greatly improved the field of corneal imaging. Devices such as the Orbscan (Bausch & Lomb Surgical, Inc) and, more recently, the Pentacam (Oculus, Inc) and the Galilei (Ziemer Ophthalmic Systems AG) have brought a whole new range of clinical possibilities and sparked interest in the academic community. These new tomographers create three-dimensional models of the cornea and enable the direct measurement of both the anterior and posterior surface elevations. In this paper, we present a review of some available literature on those systems, regarding their optical principles and their performance in current clinical applications.
引用
收藏
页码:33 / 42
页数:10
相关论文
共 50 条
  • [41] A corneal elastic dynamic model derived from Scheimpflug imaging technology
    Shih, Po-Jen
    Cao, Huei-Jyun
    Huang, Chun-Ju
    Wang, I-Jong
    Shih, Wen-Pin
    Yen, Jia-Yush
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2015, 35 (06) : 663 - 672
  • [42] Scheimpflug Backscatter Imaging of the Fibrillar Layer in Fuchs Endothelial Corneal Dystrophy
    Hribek, Agathe
    Mestanoglu, Mert
    Clahsen, Thomas
    Reinking, Niklas
    Frentzen, Falk
    Howaldt, Antonia
    Siebelmann, Sebastian
    Bachmann, Bjoern O.
    Cursiefen, Claus
    Matthaei, Mario
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 235 : 63 - 70
  • [43] Spiral Scanning Imaging Techniques
    Macovski, Albert
    Meyer, Craig H.
    eMagRes, 2007, 2007
  • [44] Corneal Deformation Dynamics in Normal and Glaucoma Patients Utilizing Scheimpflug Imaging
    Rogowska, Marta E.
    Iskander, D. Robert
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 6261 - 6264
  • [45] Corneal and lenticular clarity in children with inflammatory disease as assessed by Scheimpflug imaging
    Cetin, Ebru Nevin
    Akbulut, Selen
    Tekin, Zahide Ekici
    Yener, Gulcin Otar
    Bozkurt, Kerem
    Pekel, Gokhan
    Yuksel, Selcuk
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2022, 39
  • [46] Comparison of Scheimpflug Imaging Analysis of Pellucid Marginal Corneal Degeneration and Keratoconus
    Kocluk, Yusuf
    Yalniz-Akkaya, Zuleyha
    Burcu, Ayse
    Ornek, Firdevs
    OPHTHALMIC RESEARCH, 2015, 53 (01) : 21 - 27
  • [47] Corneal biomechanical properties in myopic eyes evaluated via Scheimpflug imaging
    Yu, A-Yong
    Shao, Hui
    Pan, Anpeng
    Wang, Qinmei
    Huang, Zixu
    Song, Benhao
    McAlinden, Colm
    Huang, Jinhai
    Chen, Sisi
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [48] Evaluation of Corneal Parameters with Dual Scheimpflug Imaging in Patients with Systemic Sclerosis
    Gomes, Beatriz Fiuza
    Santhiago, Marcony R.
    Kara-Junior, Newton
    Moraes, Haroldo Vieira, Jr.
    CURRENT EYE RESEARCH, 2018, 43 (04) : 451 - 454
  • [49] Assessment of Corneal Parameters in Patients with Constitutional Thinness Using Scheimpflug Imaging
    Gunes, Alime
    Bas, Funda Yildirim
    Arslan, Bahriye
    Tok, Levent
    Tok, Ozlem
    Salman, Zeliha
    SEMINARS IN OPHTHALMOLOGY, 2018, 33 (02) : 175 - 178
  • [50] Corneal topography with Scheimpflug imaging and videokeratography: Comparative study of normal eyes
    Read, Scott A.
    Collins, Michael J.
    Iskander, Robert
    Davis, Brett A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (06): : 1072 - 1081