Experimental Study of Seismic Reduced Performance of Series Isolation System

被引:0
|
作者
Wu, Zhongtie [1 ]
机构
[1] Northwest Univ Nationalities, Sch Civil Engn, Lanzhou 730030, Peoples R China
关键词
series isolation system; seismic reduced performance; shaking table test; response spectrum method; earthquake intensity; near fault ground motion; multidimensional seismic excitation;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In order to study the seismic reduced performances (SRP) of series isolation systems (SIS) under multi-dimensional seismic excitation (MDSE), a series of shaking table tests had been conducted for the SIS model. The two groups of seismic waves, including the near fault ground motion and far fault ground motion were firstly chose from the Chichi earthquakes as the input. The responses of SIS under the different seismic waves were predicted by response spectrum method. The paper discussed the effect of earthquake intensity on SRP of SIS under different input patterns, and further analyzed the effect of near fault ground motion and far fault ground motion on the SRP, and compared to the predicted results. The results show that, compared to near fault ground motion, the seismic reduced ratio (SRR) of SIS is better under the far fault ground motion. The SRR of SIS increases with increasing the earthquake intensity, but it is obvious under near fault ground motion. The test results are consisted with the predicted results. The SRRs are small for the different shaking table tests, so the SRP of SIS is better. Moreover, the SRP under 2-dimensional seismic excitation is consistent with that under 3-dimensional seismic excitation with increasing the earthquake intensity.
引用
收藏
页码:490 / 494
页数:5
相关论文
共 50 条
  • [21] Performance Experimental Study and Vibration Isolation Parameter Analysis on Vertical Seismic Isolation Device with Hydraulic Jack and Accumulator
    Lu, Liang
    Wang, Lei
    Xia, Wanqiu
    Li, Yuanqing
    [J]. Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2024, 51 (11): : 1 - 11
  • [22] Experimental and parametric study of a novel braced system to improve seismic performance
    Ghiasvandan, Mehdi
    Alirezaei, Mehdi
    Mirhosseini, S. Mohammad
    Zeighami, Ehsanollah
    [J]. STRUCTURES, 2022, 45 : 229 - 242
  • [23] ISOLATION PERFORMANCE OF INTELLIGENT SEISMIC ISOLATION SYSTEM USING AIR BEARING
    Fujita, Satoshi
    Minagawa, Keisuke
    Miyazaki, Mitsuru
    Tanaka, Go
    Omi, Toshio
    Shimosaka, Haruo
    [J]. ASME PRESSURE VESSELS AND PIPING CONFERENCE, VOL 8: SEISMIC ENGINEERING, 2010, : 199 - 204
  • [24] Seismic performance of isolation system of rolling friction with springs
    Wei Biao
    Dai Gong-lian
    Wen Ying
    Xia Ye
    [J]. JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2014, 21 (04) : 1518 - 1525
  • [25] Seismic performance of isolation system of rolling friction with springs
    魏标
    戴公连
    文颖
    夏烨
    [J]. Journal of Central South University, 2014, 21 (04) : 1518 - 1525
  • [26] Seismic performance of isolation system of rolling friction with springs
    Biao Wei
    Gong-lian Dai
    Ying Wen
    Ye Xia
    [J]. Journal of Central South University, 2014, 21 : 1518 - 1525
  • [27] Seismic performance of a rolling-damper isolation system
    Wei, Biao
    Cui, Ruibo
    Dai, Gonglian
    [J]. JOURNAL OF VIBROENGINEERING, 2013, 15 (03) : 1504 - 1512
  • [28] Effects of shear keys on seismic performance of an isolation system
    Wei, Biao
    Li, Chaobin
    Jia, Xiaolong
    He, Xuhui
    Yang, Menggang
    [J]. SMART STRUCTURES AND SYSTEMS, 2019, 24 (03) : 345 - 360
  • [29] Assessment of Performance of Seismic Isolation System of Bolu Viaduct
    Roussis, Panayiotis C.
    Constantinou, Michael C.
    Erdik, Mustafa
    Durukal, Eser
    Dicleli, Murat
    [J]. JOURNAL OF BRIDGE ENGINEERING, 2003, 8 (04) : 182 - 190
  • [30] Experimental Study on Seismic Isolation Bearing of Large Aqueduct
    Jiang, Yinjun
    Zhou, Yanguo
    Song, Yile
    [J]. VIBRATION, STRUCTURAL ENGINEERING AND MEASUREMENT II, PTS 1-3, 2012, 226-228 : 1693 - 1696