Three-Dimensional Imaging-Based Web Application for Predicting Tracheal Tube Depth in Preterm Neonates

被引:3
|
作者
Tupprasoot, Raksa [1 ]
Langan, Dean [2 ]
Hutchinson, J. Ciaran [1 ,2 ]
Barrett, Hannah [1 ,2 ]
Sury, Michael R. J. [1 ,2 ]
Arthurs, Owen J. [1 ,2 ]
机构
[1] Great Ormond St Hosp Children NHS Fdn Trust, London WC1N 3JH, England
[2] UCL, UCL Great Ormond St Inst Child Hlth, London, England
关键词
Airway; Trachea; Post-mortem magnetic resonance imaging; Foetus; BIRTH-WEIGHT INFANTS; NEWBORN-INFANT; INTUBATION; POSITION; INSERTION; LENGTH;
D O I
10.1159/000455036
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: Positioning a tracheal tube (TT) to the correct depth in preterm infants is challenging. Currently, there is no reliable single-predictor model for neonates applicable to the whole range of size or age. Objective: In this study, we used post-mortem magnetic resonance imaging (PMMRI) of preterm infants to measure tracheal dimensions and to develop a clinical guide for TT positioning. Methods: We measured tracheal length (TL) and tracheal diameter TD) in a cohort of normal neonates and foetuses that underwent PMMRI (cause of death unexplained). The distance between the lips and the mid-tracheal point, i.e., the mid-tracheal length (mid-TL), and the TD measurement were obtained. We produced univariate prediction models of mid-TL and TD, using gestational age (GA), foot length (FL), crown-rump length (CRL) and body weight (BW) as potential predictors, as well as multiple prediction models for mid-TL. Results: Tracheal measurements were performed in 117 cases, with a mean GA of 28.8 weeks (range 14-42 weeks). The best linear association was between mid-TL and FL (mid-TL = FL x 0.914 + 1.859; R-2 = 0.94), but was improved by multivariate regression models. We developed a prediction tool using only GA and BW (R-2 = 0.92), and all four predictors (GA, BW, FL and CRL; R-2 = 0.94) which is now available as a web-based application via the Internet. Conclusion: Post-mortem imaging data provide estimates of TT insertion depth. Our prediction tool based on age and BW can be used at the bedside and is ready to be tested in clinical practice. (C) 2017 S. Karger AG, Basel
引用
收藏
页码:376 / 382
页数:7
相关论文
共 50 条
  • [21] Image estimation based on depth-variant imaging model in three-dimensional microscopy
    Tao, QC
    He, XH
    Zhao, J
    Teng, QZ
    Chen, JG
    Electronic Imaging and Multimedia Technology IV, 2005, 5637 : 590 - 598
  • [22] Single-pixel three-dimensional imaging with time-based depth resolution
    Sun, Ming-Jie
    Edgar, Matthew P.
    Gibson, Graham M.
    Sun, Baoqing
    Radwell, Neal
    Lamb, Robert
    Padgett, Miles J.
    NATURE COMMUNICATIONS, 2016, 7
  • [23] Single-pixel three-dimensional imaging with time-based depth resolution
    Ming-Jie Sun
    Matthew P. Edgar
    Graham M. Gibson
    Baoqing Sun
    Neal Radwell
    Robert Lamb
    Miles J. Padgett
    Nature Communications, 7
  • [24] Case report: Magnetic resonance imaging-based three-dimensional printing for reconstruction of complex cloacal malformations
    Gang, Suiin
    Song, Sang Hoon
    Kwon, Jaeyoung
    Kwon, Hyunhee
    Ha, Suhyeon
    Park, Jueun
    Kim, Namkug
    Yoon, Hee Mang
    Namgoong, Jung-Man
    FRONTIERS IN PEDIATRICS, 2023, 11
  • [25] Three-dimensional proton MR spectroscopic imaging of premature and term neonates
    Vigneron, DB
    Barkovich, AJ
    Noworolski, SM
    von dem Bussche, M
    Henry, RG
    Lu, Y
    Partridge, JC
    Gregory, G
    Ferriero, DM
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2001, 22 (07) : 1424 - 1433
  • [26] Combination of tomographic ultrasound imaging and three-dimensional magnetic resonance imaging-based model to diagnose postpartum levator avulsion
    Yan, Yulin
    Dou, Chaoran
    Wang, Xia
    Xi, Yan
    Hu, Bing
    Ma, Li
    Ying, Tao
    SCIENTIFIC REPORTS, 2017, 7
  • [27] Three-dimensional visualization of major white matter tracts by diffusion tensor imaging-based fiber tracking
    Nimsky, C
    Ganslandt, O
    Sorensen, AG
    Fahlbusch, R
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 703 - 706
  • [28] Three-dimensional integral imaging-based image descattering and recovery using physics informed unsupervised CycleGAN
    Krishnan, Gokul
    Goswami, Saurabh
    Joshi, Rakesh
    Javidi, Bahram
    OPTICS EXPRESS, 2024, 32 (02) : 1825 - 1835
  • [29] Three-dimensional Modeled T-tube Design and Insertion in a Patient With Tracheal Dehiscence
    Cheng, George Z.
    Folch, Erik
    Brik, Robert
    Gangadharan, Sidhu
    Mallur, Pavan
    Wilson, Jennifer H.
    Husta, Bryan
    Majid, Adnan
    CHEST, 2015, 148 (04) : E106 - E108
  • [30] The three-dimensional computed tomography imaging and prediction of unanticipated difficult tracheal intubation
    Naguib, M
    ANESTHESIA AND ANALGESIA, 2001, 92 (01): : 281 - 281