Precise measurement of uranium isotope ratios in Fukushima soils using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)

被引:10
|
作者
Murugan, Rajamanickam [1 ]
Veerasamy, Nimelan [1 ,2 ]
Zhao, Ye [3 ]
Aono, Tatsuo [1 ]
Sahoo, Sarata Kumar [1 ]
机构
[1] Natl Inst Quantum & Radiol Sci & Technol QST, Environm Radionuclide Res Grp, 4-9-1 Anagawa, Chiba 2638555, Japan
[2] Inst Environm Sci, Environm Impact Res Dept, 1-7 Ienomae, Aomori 0393212, Japan
[3] Nu Instruments Ltd, Unit 74, Clywedog Rd South, Wrexham LL13 9XS, Wales
关键词
MC-ICP-MS; Daly detector; U-234/U-238; U-235/U-238; Fukushima soil sample; UTEVA resin; SILICATE ROCK SAMPLES; ENVIRONMENTAL-SAMPLES; THORIUM; OPTIMIZATION; SEPARATION; PLUTONIUM;
D O I
10.1016/j.ijms.2021.116623
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Precise measurement of U-234/U-238 and U-235/U-238 isotope ratios was performed using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) in this study. The U-234 ions were measured using a Daly detector, the U-235 ions were measured using a Faraday cup with a 10(12) Omega resistor, and the U-238 ions were measured using a Faraday cup with the usual 10(11) Omega resistor. Chemical separation of uranium was carried out by three different methods using either combinations of anion exchange and UTEVA resins or UTEVA resin three times. Chromatography combining three UTEVA resin columns provided the highest recovery (%) of uranium and biggest improvement in precise measurements of uranium isotope ratios. The certificate reference material (CRM) JLk-1 was used as an in-house standard for the uranium isotope ratio measurements. The long-term reproducibility of the in-house standard was 0.60% for U-234/U-238 and 0.05% for U-235/U-238. The measured ratios were compared with the natural ratios, and the relative deviation obtained for uranium isotope ratios was less than 0.005% for U-234/U-238 and U-235/U-238. Finally, the present method was applied to measure uranium isotope ratios in Fukushima microwave-digested soil samples. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Lead isotope measurement using a multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    Choi, Hye-Bin
    Ryu, Jong-Sik
    Park, Sanghee
    Lee, Jeonghoon
    JOURNAL OF THE GEOLOGICAL SOCIETY OF KOREA, 2018, 54 (03) : 311 - 318
  • [2] Precise measurement of Fe isotopes in marine samples by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    de Jong, Jeroen
    Schoemann, Veronique
    Tison, Jean-Louis
    Becquevort, Sylvie
    Masson, Florence
    Lannuzel, Delphine
    Petit, Jerome
    Chou, Lei
    Weis, Dominique
    Mattielli, Nadine
    ANALYTICA CHIMICA ACTA, 2007, 589 (01) : 105 - 119
  • [3] Determination of indium isotopic ratios of geostandards with different matrices by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    Zhu, Chuanwei
    Wu, Yunzhu
    Liu, Zerui
    Zhou, Meifu
    Yang, Guangshu
    Zhang, Yuxu
    Wen, Hanjie
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (07) : 1867 - 1873
  • [4] Measurement of isotopic ratios of uranium by multi-collector inductively coupled plasma mass spectrometry
    Li, Li-Li
    Li, Jin-Ying
    Zhao, Yong-Gang
    Liu, Jun-Ling
    Zhang, Ji-Long
    He-Huaxue yu Fangshe Huaxue/Journal of Nuclear and Radiochemistry, 2006, 28 (03): : 152 - 156
  • [5] Precise selenium isotope ratios measurement using a multimode sample introduction system (MSIS) coupled with multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    Elwaer, Nagmeddin
    Hintelmann, Holger
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (10) : 1392 - 1396
  • [6] Precise selenium isotope ratios measurement using a multimode sample introduction system (MSIS) coupled with multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    Elwaer, Nagmeddin
    Hintelmann, Holger
    Journal of Analytical Atomic Spectrometry, 2008, 23 (10): : 1392 - 1396
  • [7] Accurate measurement of uranium isotope ratios in solid samples by laser ablation multi-collector inductively coupled plasma mass spectrometry
    Varga, Z.
    Krachler, M.
    Nicholl, A.
    Ernstberger, M.
    Wiss, T.
    Wallenius, M.
    Mayer, K.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (06) : 1076 - 1080
  • [8] Measurement of uranium isotope ratios in Fukushima-accident contaminated soil samples using multi collector inductively coupled plasma mass spectrometry
    Murugan, R.
    Kavasi, N.
    Sahoo, S. K.
    Omori, Y.
    Sorimachi, A.
    Takahashi, H.
    Aono, T.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2021, 232
  • [9] ACTIVITY RATIO OF URANIUM IN FUKUSHIMA SOIL SAMPLES USING MULTI-COLLECTOR INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY
    Murugan, Rajamanickam
    Sahoo, Sarata Kumar
    Sorimachi, Atsuyuki
    Omori, Yasutaka
    Aono, Tatsuo
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (13-15) : 934 - 937
  • [10] Evaluation of multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) for sulfur metabolic studies using 34S-labelled yeast
    Galilea San Blas, Oscar
    Marchante Gayon, Juan Manuel
    Garcia Alonso, Jose Ignacio
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (08) : 1764 - 1773