The treatment of periprosthetic fractures with locking plates: effect of drill and screw type on cement mantles: a biomechanical analysis

被引:24
|
作者
Kampshoff, Jorg [1 ,4 ]
Stoffel, Karl K. [3 ,4 ]
Yates, Piers J. [1 ,4 ]
Erhardt, Johannes B. [2 ]
Kuster, Markus S. [2 ,4 ]
机构
[1] Fremantle Hosp, Dept Orthopaed Surg, Fremantle, WA 6160, Australia
[2] Kantonsspital, Dept Orthopaed Surg, CH-9007 St Gallen, Switzerland
[3] Kantonsspital Graubunden, Dept Orthopaed Surg, CH-7000 Chur, Switzerland
[4] Univ Western Australia, Crawley, WA 6009, Australia
关键词
Locking screws; Periprosthetic femur fracture; Bone cement; Pullout; Loosening; TOTAL HIP-ARTHROPLASTY; FEMORAL FRACTURES; FEMUR; CLASSIFICATION; FIXATION; STEM; MANAGEMENT; PROSTHESES; TIP;
D O I
10.1007/s00402-009-0952-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Periprosthetic fractures after cemented hip replacement are a challenging problem to manage. Biomechanical studies have suggested the benefit of using locking screws for plate fixation, but there are concerns whether screws damage the cement mantle and promote crack propagation leading to construct failure. In this biomechanical study, different screw types were implanted into the cement mantle after pre-drilling holes of different sizes, in unicortical and bicortical configuration. The presence of cracks and the pull-out resistance of these screws were then evaluated. No unicortical screw induced cracks. Screws with a shortened tip, smaller flutes and double threads were significantly better for pull-out resistance. Bicortical screws were associated with a risk of local cement mantle damage, but also with a significantly greater holding power. By increasing the drill diameter, the onset of cracks decreased, but so does the pull-out resistance.
引用
收藏
页码:627 / 632
页数:6
相关论文
共 50 条
  • [31] Locking Compression Plates for the Treatment of Periprosthetic Femoral Fractures Around Well-Fixed Total Hip and Knee Implants
    Wood, Gavin C. A.
    Naudie, Doug R.
    McAuley, James
    McCalden, Richard W.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (06): : 886 - 892
  • [32] Comparison of Bite Force with Locking Plates versus Non-Locking Plates in the Treatment of Mandibular Fractures: A Meta-Analysis
    Ramos Gloria, Jose Cristiano
    Fernandes, Ighor Andrade
    da Silveira, Esmeralda Maria
    de Souza, Glaciele Maria
    Rocha, Ricardo Lopes
    Galvao, Endi Lanza
    Moreira Falci, Saulo Gabriel
    INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2018, 22 (02) : 181 - 189
  • [33] A biomechanical comparison of fixed angle locking compression plate osteosynthesis and cement augmented screw osteosynthesis in the management of intra articular calcaneal fractures
    Sascha Rausch
    Kajetan Klos
    Uwe Wolf
    Marc Gras
    Paul Simons
    Steffen Brodt
    Markus Windolf
    Boyko Gueorguiev
    International Orthopaedics, 2014, 38 : 1705 - 1710
  • [34] A biomechanical comparison of fixed angle locking compression plate osteosynthesis and cement augmented screw osteosynthesis in the management of intra articular calcaneal fractures
    Rausch, Sascha
    Klos, Kajetan
    Wolf, Uwe
    Gras, Marc
    Simons, Paul
    Brodt, Steffen
    Windolf, Markus
    Gueorguiev, Boyko
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (08) : 1705 - 1710
  • [35] Lower reoperation rate with locking plates compared with conventional plates in Vancouver type C periprosthetic femoral fractures: A register study of 639 cases in Sweden
    Chatziagorou, Georgios
    Lindahl, Hans
    Karrholm, Johan
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (12): : 2292 - 2300
  • [36] The addition of cerclage wiring does not improve proximal bicortical fixation of locking plates for Type C periprosthetic fractures in synthetic humeri
    Gupta, Richa
    Schmidt, Elaine C.
    Namdari, Surena
    Stone, Michael A.
    Hast, Michael W.
    CLINICAL BIOMECHANICS, 2022, 97
  • [37] Impact of cement-augmented condylar screws in locking plate osteosynthesis for distal femoral fractures - A biomechanical analysis
    Bliemel, Christopher
    Oberkircher, Ludwig
    Bockmann, Benjamin
    Petzold, Eric
    Aigner, Rene
    Heyse, Thomas Jan
    Ruchholtz, Steffen
    Buecking, Benjamin
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (12): : 2688 - 2693
  • [38] The use of LISS femoral locking plates and cabling in the treatment of periprosthetic fractures around stable proximal femoral implants in elderly patients
    Currall, V.
    Thomason, K.
    Eastaugh-Waring, S.
    Ward, A. J.
    Chesser, T. J. S.
    HIP INTERNATIONAL, 2008, 18 (03) : 207 - 211
  • [39] Locking plates versus retrograde intramedullary nails in the treatment of periprosthetic supracondylar knee fractures. A retrospective multicenter comparative study
    Kyriakidis, Theofylaktos
    Kenanidis, Eustathios
    Akula, Maheswara R.
    Zorman, David
    Tsiridis, Eleftherios
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (10): : 1745 - 1749
  • [40] An alternative treatment for osteoporotic Su Type III periprosthetic supracondylar femur fractures: Double locking plate fixation
    Cicek, Hakan
    Tuhanioglu, Umit
    Ogur, Hasan Ulas
    Seyfettinoglu, Firat
    Bozkurt, Murat
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2018, 52 (02) : 92 - 96