Thermodynamic performance assessment of ammonia/ionic liquid based half-effect absorption refrigeration cycle

被引:6
|
作者
Gong, Yulie [1 ,2 ,3 ]
Yang, Lei [1 ,2 ,3 ,4 ]
Lu, Zhenneng [1 ,2 ,3 ]
Wang, Lingbao [1 ,2 ,3 ]
Li, Huashan [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Guangzhou Inst Energy Convers, Guangzhou 510640, Peoples R China
[2] CAS Key Lab Renewable Energy, Guangzhou 510640, Peoples R China
[3] Guangdong Prov Key Lab New & Renewable Energy Res, Guangzhou 510640, Peoples R China
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
关键词
Half-effect absorption refrigeration cycle; Ammonia; Ionic liquid; Low-grade thermal source; Thermodynamic performance; IONIC LIQUIDS; ZEOTROPIC MIXTURES; HEAT-CAPACITIES; WASTE HEAT; TEMPERATURE; SYSTEMS; DRIVEN; WATER; TECHNOLOGIES; RECOVERY;
D O I
10.1016/j.csite.2021.100924
中图分类号
O414.1 [热力学];
学科分类号
摘要
The potential of ammonia/ionic liquids half-effect absorption refrigeration cycle (ARC) has been investigated. The thermodynamic model of the half-effect ARC and the property models of ammonia/ionic liquid working pairs have been established with verified accuracy. In addition, the thermodynamic and economic performance comparisons between the four ammonia/ionic liquid working pairs and ammonia/water in the half-effect ARC cycle are conducted. With coefficient of performance (COP) and solution circulation ratio as key performance indicators in this paper, the results reveal that, in general, the COP of the four ammonia/ionic liquid working pairs is higher than that of the ammonia/water, and there exists an optimum generation temperature for the cycle to achieve the highest COP. With the cooling capacity per unit UA, the cycle's economic performance is studied. Under the typical operating conditions, the COP of working pairs with [emim][BF4] has the highest value (0.342), followed by [dema][Ac] (0.330), [dmim] [DMP] (0.300) and [emim][SCN] with the lowest value (0.293). And the cooling capacity per unit UA of ammonia/[emim][BF4] has the highest value. Moreover, compared to the other candidates, ammonia/[emim][BF4] performs best under most operating conditions and can be recommended as a reasonable working pair for the half-effect ARC.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Thermodynamic Analysis of a New Combined Cooling and Power System Coupled by the Kalina Cycle and Ammonia-Water Absorption Refrigeration Cycle
    Wang, Haojin
    Wang, Jianyong
    Liu, Zhuan
    Chen, Haifeng
    Liu, Xiaoqin
    [J]. SUSTAINABILITY, 2022, 14 (20)
  • [32] Performance assessment and optimization of a novel geothermal combined cooling and power system integrating an organic flash cycle with an ammonia-water absorption refrigeration cycle
    Wu, Chuang
    Xu, Xiaoxiao
    Li, Qibin
    Li, Xiaoxiao
    Liu, Lang
    Liu, Chao
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2021, 227
  • [33] Performance of a Hybrid TEG/Single Stage Ammonia-Water Absorption Refrigeration Cycle with a Combined Effect of Rectifier and Condensate Precooler
    Al-Tahaineh, Hamza
    Okour, Mohamad H.
    Al-Rashdan, M.
    Al Essa, Fayez M. S.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2022, 40 (01) : 98 - 104
  • [34] Thermodynamic analysis of a combined cycle of ammonia-based battery and absorption refrigerator
    Zhang, Shaozhi
    Luo, Jielin
    Xu, Yiyang
    Chen, Guangming
    Wang, Qin
    [J]. ENERGY, 2021, 220
  • [35] Absorption refrigeration cycles based on ionic liquids: Refrigerant/absorbent selection by thermodynamic and process analysis
    Moreno, Daniel
    Ferro, Victor R.
    de Riva, Juan
    Santiago, Ruben
    Moya, Cristian
    Larriba, Marcos
    Palomar, Jose
    [J]. APPLIED ENERGY, 2018, 213 : 179 - 194
  • [36] Performance assessment of a solar powered ammonia-water absorption refrigeration system with storage units
    Khan, Mohammed Mumtaz A.
    Ibrahim, Nasiru I.
    Saidur, R.
    Mahbubul, I. M.
    Al-Sulaiman, Fahad A.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2016, 126 : 316 - 328
  • [37] Thermodynamic analysis of absorption refrigeration cycles using ionic liquid plus supercritical CO2 pairs
    Martin, Angel
    Dolores Bermejo, Maria
    [J]. JOURNAL OF SUPERCRITICAL FLUIDS, 2010, 55 (02): : 852 - 859
  • [38] Thermodynamic performance analysis of a single-effect absorption refrigeration system operating with water and 1-ethyl-3-methylimidazolium-based ionic liquids mixtures
    de Araujo, Hugo Valenca
    Parolin Massuchetto, Luiz Henrique
    Correa do Nascimento, Raiza Barcelos
    Rocha de Carvalho, Stella Maia
    Hallak Dangelo, Jose Vicente
    [J]. APPLIED THERMAL ENGINEERING, 2022, 201
  • [39] Thermodynamic analysis of triple effect ammonia-water absorption compression (hybrid) cycle
    Jawahar, C. P.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2021, 235 (03) : 670 - 678
  • [40] Thermodynamic performance assessment of an ammonia-water Rankine cycle for power and heat production
    Wagar, W. R.
    Zamfirescu, C.
    Dincer, I.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (12) : 2501 - 2509