A critical decrease in dominant frequency and clinical outcome after catheter ablation of persistent atrial fibrillation

被引:60
|
作者
Yoshida, Kentaro [1 ]
Chugh, Aman [1 ]
Good, Eric [1 ]
Crawford, Thomas [1 ]
Myles, James [2 ]
Veerareddy, Srikar [1 ]
Billakanty, Sreedhar [1 ]
Wong, Wai S. [1 ]
Ebinger, Matthew [1 ]
Pelosi, Frank [1 ]
Jongnarangsin, Krit [1 ]
Bogun, Frank [1 ]
Morady, Fred [1 ]
Oral, Hakan [1 ]
机构
[1] Univ Michigan, Div Cardiovasc Med, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Michigan Inst Clin Hlth Res, Ann Arbor, MI 48109 USA
关键词
Atrial fibrillation; Catheter ablation; Endpoint; Dominant frequency; CIRCUMFERENTIAL ABLATION; ELECTROGRAMS; TACHYCARDIA; TRIGGER;
D O I
10.1016/j.hrthm.2009.11.024
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Termination of persistent atrial fibrillation (AF) by radiofrequency ablation (RFA) is associated with a high probability of freedom from AF but requires extensive ablation and long procedure times. OBJECTIVE The purpose of this study was to determine whether a critical decrease in the dominant frequency (DF) of AF is a sufficient endpoint for RFA of persistent AF. METHODS Antral pulmonary vein isolation (APVI) followed by RFA of complex fractionated atrial electrograms (CFAEs) in the atria and coronary sinus was performed in 100 consecutive patients with persistent AF. The DF of AF in lead V1 and in the coronary sinus was determined by fast Fourier transform (FFT) analysis at baseline and before termination of AF to identify a critical decrease in DF predictive of sinus rhythm after RFA. RESULTS A >= 11% decrease in DF had the highest accuracy in predicting freedom from atrial arrhythmias, with a sensitivity of 0.71 and a specificity of 0.82 (P <.001). At a mean follow-up of 14 +/- 3 months after one ablation procedure, sinus rhythm was maintained off antiarrhythmic drugs in 8/35 (23%) and 20/26 (77%) of patients with a <11% and >= 11% decrease in DF, respectively (P <.001). Sinus rhythm was maintained in 24/39 patients (62%) in whom RFA terminated AF. The duration of RFA and total procedure time were longer in patients with AF termination (95 +/- 23 and 358 +/- 87 minutes) than in patients with a >= 11% decrease in the DF (77 +/- 16 and 293 +/- 70 minutes) or >= 11% decrease in DF (80 +/- 17 and 289 +/- 73 minutes), respectively (P <.01). Among the variables of age, gender, left atrial diameter, duration of AF, left ventricular ejection fraction, duration of RFA, a >= 11% decrease in DF, and termination of AF, a >= 11% decrease in DF (odds ratio = 9.89, 95% confidence interval [CI] 2.84-34.47) and termination during RFA (OR = 4.38, 95% CI 1.50-12.80) were the only independent predictors of freedom from recurrent atrial arrhythmias. CONCLUSION In a retrospective analysis of consecutive patients with persistent AF, a decrease in the DF of AF by 11% in response to APVI and ablation of CFAEs was associated with a probability of maintaining sinus rhythm that was similar to that when RFA terminates AF.
引用
收藏
页码:295 / 302
页数:8
相关论文
共 50 条
  • [21] Anticoagulation use and clinical outcomes after catheter ablation in patients with persistent and longstanding persistent atrial fibrillation
    Liang, Jackson J.
    Elafros, Melissa A.
    Mullen, Michael T.
    Muser, Daniele
    Hayashi, Tatsuya
    Enriquez, Andres
    Pathak, Rajeev K.
    Zado, Erica S.
    Santangeli, Pasquale
    Arkles, Jeffrey S.
    Schaller, Robert D.
    Supple, Gregory E.
    Frankel, David S.
    Garcia, Fermin C.
    Deo, Rajat
    Lin, David
    Riley, Michael P.
    Nazarian, Aman
    Dixit, Anjay
    Marchlinski, Francis E.
    Callans, David J.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (06) : 823 - 832
  • [22] Drifting Rotor Prevalence is associated with Dominant Frequency Reduction after Persistent Atrial Fibrillation Ablation
    Salinet, Joao L.
    Guillem, Maria S.
    Almeida, Tiago P.
    Li, Xin
    Goroso, Gustavo
    Chu, Gavin S.
    Ng, G. Andre
    Schlindwein, Fernando S.
    2015 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2015, 42 : 269 - 272
  • [23] Reverse atrial electrical remodeling after catheter ablation of persistent atrial fibrillation
    Lo, Li-Wei
    Tai, Ching-Tai
    Lin, Yenn-Jiang
    Chang, Shih-Lin
    Wongcharoen, Wanwarang
    Chen, Shih-Ann
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (07) : 798 - 799
  • [24] Catheter ablation for paroxysmal and persistent atrial fibrillation
    Chen, Huai Sheng
    Wen, Jun Min
    Wu, Sheng Nan
    Liu, Jian Ping
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2012, (04):
  • [25] Approaches to catheter ablation of persistent atrial fibrillation
    Smelley, Matthew P.
    Knight, Bradley P.
    HEART RHYTHM, 2009, 6 (08) : S33 - S38
  • [26] Approaches to Catheter Ablation for Persistent Atrial Fibrillation
    Verma, Atul
    Jiang, Chen-Yang
    Betts, Timothy R.
    Chen, Jian
    Deisenhofer, Isabel
    Mantovan, Roberto
    Macle, Laurent
    Morillo, Carlos A.
    Haverkamp, Wilhelm
    Weerasooriya, Rukshen
    Albenque, Jean-Paul
    Nardi, Stefano
    Menardi, Endrj
    Novak, Paul
    Sanders, Prashanthan
    NEW ENGLAND JOURNAL OF MEDICINE, 2015, 372 (19): : 1812 - 1822
  • [27] Catheter ablation in patients with persistent atrial fibrillation
    Kirchhof, Paulus
    Calkins, Hugh
    EUROPEAN HEART JOURNAL, 2017, 38 (01) : 20 - +
  • [28] Strategies of catheter ablation of persistent atrial fibrillation
    Ma Chang-sheng
    CHINESE MEDICAL JOURNAL, 2013, 126 (14) : 2603 - 2606
  • [29] Strategies of catheter ablation of persistent atrial fibrillation
    MA Chang-sheng
    中华医学杂志(英文版), 2013, 126 (14) : 2603 - 2606
  • [30] PentaRay catheter in persistent atrial fibrillation ablation
    Teixeira, Pedro Pinto
    Cunha, Pedro Silva
    Delgado, Ana Sofia
    Pimenta, Ricardo
    Oliveira, Mario Martins
    Ferreira, Rui Cruz
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2016, 35 (02) : 121 - 123