Performance characteristics of the button personal inhalable aerosol sampler

被引:77
|
作者
Aizenberg, V
Grinshpun, SA [1 ]
Willeke, K
Smith, J
Baron, PA
机构
[1] Univ Cincinnati, Dept Environm Hlth, Aerosol Res & Exposure Assessment Lab, Cincinnati, OH 45267 USA
[2] NIOSH, Ctr Dis Control & Prevent, US Dept HHS, Cincinnati, OH 45226 USA
来源
关键词
inhalable aerosols; personal sampling; wind tunnel evaluation;
D O I
10.1080/15298660008984550
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The button inhalable aerosol sampler with a curved porous inlet recently was developed and evaluated as a stationary sampler in the laboratory and in the field. The present study focused on investigating its suitability far personal inhalable aerosol sampling. The button sampler was tested at two wind velocities (0.5 and 2.0 m/sec), three particle sizes (7, 29, and 70 mu m) and three orientations to the wind (0, 90, and 180 degrees). The performance characteristics of the button sampler were compared with those of three other personal samplers-the IOM (Institute of Occupational Medicine), GSP, and 37-mm closed-face filter cassette. The experiments were conducted in a wind tunnel with the samplers mounted on a full-size manikin. The direction-specific sampling efficiency of the button sampler was found to be essentially independent of the wind direction and dependent on the wind velocity to a much smaller degree than that of the three other samplers. When direction-averaged, the fit of its sampling efficiency curve to the inhalability curve was found to be better than that of the 37-mm closed-face cassette, comparable with that of the GSP sampler, and less than that of the IOM sampler. The precision of the button sampler was found to be generally equal to or better than the precision of the comparison samplers. it was concluded that the button sampler can be successfully used as a personal inhalable aerosol sampler.
引用
收藏
页码:398 / 404
页数:7
相关论文
共 50 条
  • [41] Aerosol Sampler
    Brown, Jason
    Saka, Nana
    Norris, Wilton
    Kher, Shubhalaxmi
    PROCEEDINGS OF 2016 FUTURE TECHNOLOGIES CONFERENCE (FTC), 2016, : 681 - 688
  • [42] Development and evaluation of an inhalable bioaerosol manifold sampler
    Gao, PF
    Dillon, HK
    Farthing, WE
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1997, 58 (03): : 196 - 206
  • [43] Evaluation of personal inhalable aerosol samplers with different filters for use during anthrax responses
    Grinshpun, Sergey A.
    Weber, Angela M.
    Yermakov, Michael
    Indugula, Reshmi
    Elmashae, Yousef
    Reponen, Tiina
    Rose, Laura
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2017, 14 (08) : 583 - 593
  • [44] Correlation between urinary 1-hydroxypyrene and ambient air pyrene measured with an inhalable aerosol sampler and a total dust sampler in an electrode paste plant
    Department of Toxicology, Natl. Inst. of Occupational Health, PO Box 8149 Dep., 0033 Oslo, Norway
    不详
    Sci. Total Environ., 1 (59-67):
  • [45] Correlation between urinary 1-hydroxypyrene and ambient air pyrene measured with an inhalable aerosol sampler and a total dust sampler in an electrode paste plant
    Bentsen, RK
    Halgard, K
    Noto, H
    Daae, HL
    Ovrebo, S
    SCIENCE OF THE TOTAL ENVIRONMENT, 1998, 212 (01) : 59 - 67
  • [46] Performance of prototype high-flow inhalable dust sampler in a livestock production facility
    Anthony, T. Renee
    Cai, Changjie
    Mehaffy, John
    Sleeth, Darrah
    Volckens, John
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2017, 14 (05) : 313 - 322
  • [47] AN ELECTROSTATIC AEROSOL SAMPLER
    ASKING, L
    MARTINSSON, BG
    HANSSON, HC
    JOURNAL OF AEROSOL SCIENCE, 1988, 19 (07) : 1023 - 1026
  • [48] Testing personal inhalable aerosol samplers: a suggested improved protocol based on new scientific knowledge
    Vincent, JH
    JOURNAL OF ENVIRONMENTAL MONITORING, 2006, 8 (01): : 53 - 62
  • [49] Development of a Personal Aerosol Sampler for Monitoring the Particle-Vapour Fractionation of SVOCs in Workplaces
    Dragan, George C.
    Kohlmeier, Vesta
    Orasche, Juergen
    Schnelle-Kreis, Juergen
    Forbes, Patricia B. C.
    Breuer, Dietmar
    Zimmermann, Ralf
    ANNALS OF WORK EXPOSURES AND HEALTH, 2020, 64 (08) : 903 - 908
  • [50] Comparative study of an inhalable and a total dust sampler for personal sampling of dust and polycyclic aromatic hydrocarbons in the gas and particulate phase
    Noto, H
    Halgard, K
    Daae, HL
    Bentsen, RK
    Eduard, W
    ANALYST, 1996, 121 (09) : 1191 - 1196