Bifunctional hydrogen peroxide electrode as an amperometric transducer for biosensors

被引:25
|
作者
Gamburzev, S
Atanasov, P
Ghindilis, AL
Wilkins, E [1 ]
Kaisheva, A
Iliev, I
机构
[1] Univ New Mexico, Sch Engn, Dept Chem & Nucl Engn, Albuquerque, NM 87131 USA
[2] Texas A&M Univ, Ctr Electrochem Syst & Hydrogen Res, College Stn, TX 77843 USA
[3] Bulgarian Acad Sci, Cent Lab Electrochem Power Sources, BU-1113 Sofia, Bulgaria
关键词
glucose biosensor; bienzyme electrode; non-platinum electrocatalyst; CoTMPP;
D O I
10.1016/S0925-4005(97)00134-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work presents a novel approach to design an amperometric transducer capable to detect hydrogen peroxide in anodic (oxidation) and cathodic (reduction) mode of operation, The basic transducer employs non-platinum electrocatalyst-pyrolyzed cobalt-tetramethoxy-phenylporphyrin (CoTMPP)-for H2O2 electrooxidation, and bio-electrocatalyst-horseradish peroxidase (HRP)-for H2O2 electroreduction. The bifunctional hydrogen peroxide electrode was used as an amperometric transducer in designing a glucose biosensor utilizing glucose oxidase (GOD) as second enzyme. A technique for preparation of the transducer electrode with the catalyst and adsorbed enzymes (bienzyme electrode) from a pressed matrix (tablet) of Teflonized carbon black is described, This technique allows manufacturing of numerous sensors from the same pressed tablet, all of which demonstrate good reproducibility of their parameters (sensitivity, linear range, lifetime). Bifunctional glucose sensors were operated in H2O2 oxidation mode at applied potentials from +0.2 to +0.6 V versus Ag/AgCl, and in H2O2 reduction mode at 0.0 V versus the same reference electrode. Linearity of the sensor response to glucose concentrations up to 25 mM in H2O2 reduction mode is reported. Electro-interference from some substances commonly present in physiological fluids was investigated in both reduction and oxidation modes. Sensors can be used for continuous glucose monitoring in vitro for at least 1 month with constant parameters of the signal output, Sensor demonstrated satisfactory performances in undiluted blood plasma in vitro. (C) 1997 Elsevier Science S.A.
引用
收藏
页码:70 / 77
页数:8
相关论文
共 50 条
  • [41] PEROXIDASE FERROCENE MODIFIED CARBON PASTE ELECTRODE AS AN AMPEROMETRIC SENSOR FOR THE HYDROGEN-PEROXIDE ASSAY
    SANCHEZ, PD
    ORDIERES, AJM
    GARCIA, AC
    BLANCO, PT
    [J]. ELECTROANALYSIS, 1991, 3 (4-5) : 281 - 285
  • [42] A glassy carbon electrode modified with graphene oxide and silver nanoparticles for amperometric determination of hydrogen peroxide
    Noor, An'amt Mohamed
    Shahid, Muhammad Mehmood
    Rameshkumar, Perumal
    Huang, Nay Ming
    [J]. MICROCHIMICA ACTA, 2016, 183 (02) : 911 - 916
  • [43] Amperometric hydrogen peroxide biosensor based on a glassy carbon electrode modified with polythionine and gold nanoparticles
    Qingxia Wang
    Haili Zhang
    Yiwei Wu
    Aimin Yu
    [J]. Microchimica Acta, 2012, 176 : 279 - 285
  • [44] Amperometric Determination of Hydrogen Peroxide in Whitening Gels Using Boron-doped Diamond Electrode
    Gustavo C. Azevedo
    Roberto H. S. Castro
    Maria Auxiliadora C. Matos
    Renato Camargo Matos
    [J]. Analytical Sciences, 2018, 34 : 913 - 917
  • [45] Dendrimer-rhodium nanoparticle modified glassy carbon electrode for amperometric detection of hydrogen peroxide
    Chandra, Sudeshna
    Lokesh, K. S.
    Nicolai, Anja
    Lang, Heinrich
    [J]. ANALYTICA CHIMICA ACTA, 2009, 632 (01) : 63 - 68
  • [46] Nanomolar amperometric sensing of hydrogen peroxide using a graphite pencil electrode modified with palladium nanoparticles
    Md. Abdul Aziz
    Abdel-Nasser Kawde
    [J]. Microchimica Acta, 2013, 180 : 837 - 843
  • [47] Nanomolar amperometric sensing of hydrogen peroxide using a graphite pencil electrode modified with palladium nanoparticles
    Aziz, Md Abdul
    Kawde, Abdel-Nasser
    [J]. MICROCHIMICA ACTA, 2013, 180 (9-10) : 837 - 843
  • [48] A glassy carbon electrode modified with graphene oxide and silver nanoparticles for amperometric determination of hydrogen peroxide
    An’amt Mohamed Noor
    Muhammad Mehmood Shahid
    Perumal Rameshkumar
    Nay Ming Huang
    [J]. Microchimica Acta, 2016, 183 : 911 - 916
  • [49] Amperometric hydrogen peroxide sensor using carbon electrode loaded with perovskite-type oxide
    Takase, S.
    Ishikawa, A.
    Shimizu, Y.
    [J]. 2001, Electrochemical Society of Japan (69)
  • [50] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF HYDROGEN-PEROXIDE BY OXIDATION AT AN IRIDIUM OXIDE ELECTRODE
    COX, JA