Normal vector information registration and comparisons with mutual information

被引:0
|
作者
Zhuang, Xiahai [1 ]
Gu, Lixu [2 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Comp Sci, 800 Dongchuan Rd, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, Image Guided & Theory Lab, Shanghai, Peoples R China
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We propose a new similarity measure for medical image registration and make comparisons with two kinds of mutual information (MI) methods in the literature. This new measure is computed from the normal vector information (NVI) of the images instead of pixel intensity that the NU methods based. The NVI of an image is extracted from the relationship between pixels and computed from the normal vector of the pixel based on their local isosurface. The NVI method has been proved to be able to successfully register two-dimensional (2D) images. In this paper, we will apply it in three-dimensional (3D) medical images and employ the known-result datasets to quantitatively evaluate the performances of the NVI and Nit methods. The visual assessment is employed for the unknown-result clinical image dataset registrations. The results show that the NVI method is ready to be affected by the salt-and-pepper noise; while when the random noise is removed, the NVI method performs no worse than the MI methods.
引用
收藏
页码:1335 / +
页数:2
相关论文
共 50 条
  • [31] A new method for image registration based on mutual information
    Hong, Ming-Jian
    Lü, Jian-Bin
    Yang, Dan
    Mao, You-Li
    [J]. Chongqing Daxue Xuebao/Journal of Chongqing University, 2009, 32 (06): : 697 - 700
  • [32] Automatic image registration by stochastic optimization of mutual information
    Cole-Rhodes, A
    Adenle, A
    [J]. 2003 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOL III, PROCEEDINGS: IMAGE & MULTIDIMENSIONAL SIGNAL PROCESSING SIGNAL, PROCESSING EDUCATION, 2003, : 313 - 316
  • [33] Registration using segment intensity remapping and mutual information
    Knops, ZF
    Maintz, JBA
    Viergever, MA
    Pluim, JPW
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2004, PT 1, PROCEEDINGS, 2004, 3216 : 805 - 812
  • [34] Mutual Information Driven Inverse Consistent Nonlinear Registration
    Tao, Guozhi
    He, Renjie
    Datta, Sushmita
    Narayana, Ponnada A.
    [J]. 2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 3957 - 3960
  • [35] Mutual information based registration of cardiac ultrasound volumes
    Zagrodsky, V
    Shekhar, R
    Cornhill, JF
    [J]. MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 1605 - 1614
  • [36] Nonrigid Image Registration Using Conditional Mutual Information
    Loeckx, Dirk
    Slagmolen, Pieter
    Maes, Frederik
    Vandermeulen, Dirk
    Suetens, Paul
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (01) : 19 - 29
  • [37] Multimodal image registration based on compound mutual information
    Sun, ZH
    Ray, LA
    [J]. MEDICAL IMAGING 2005: IMAGE PROCESSING, PT 1-3, 2005, 5747 : 1274 - 1282
  • [38] Registration by maximization of mutual information - A cross validation study
    Freire, L
    Godinho, F
    [J]. IEEE INTERNATIONAL SYMPOSIUM ON BIO-INFORMATICS AND BIOMEDICAL ENGINEERING, PROCEEDINGS, 2000, : 322 - 329
  • [39] Registration by automatic subimage selection and maximization of mutual information
    Anthony, A
    Lofffeld, O
    [J]. IGARSS 2005: IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-8, PROCEEDINGS, 2005, : 2783 - 2786
  • [40] Regional Weighted Mutual Information For Multimodal Rigid Registration
    Bai, Lu
    Li, Guang
    Zhu, Chuanwei
    Wu, Enhe
    Ma, Ruibing
    [J]. 2018 11TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2018), 2018,