Investigation and optimization of a solar-assisted pumped thermal energy storage system with flat plate collectors

被引:48
|
作者
Bellos, Evangelos [1 ]
Tzivanidis, Christos [1 ]
Said, Zafar [2 ,3 ]
机构
[1] Natl Tech Univ Athens, Sch Mech Engn, Thermal Dept, Heroon Polytech 9, Athens 15780, Greece
[2] Univ Sharjah, Dept Sustainable & Renewable Energy Engn, POB 27272, Sharjah, U Arab Emirates
[3] Natl Univ Sci & Technol, US Pakistan Ctr Adv Studies Energy USPCAS E, Islamabad, Pakistan
关键词
Thermal energy storage; Solar assisted storage; Organic Rankine Cycle; Heat pump; Cyclopentane; PERFORMANCE;
D O I
10.1016/j.enconman.2021.114137
中图分类号
O414.1 [热力学];
学科分类号
摘要
The objective of this work is the investigation of a solar-assisted pumped thermal energy storage system. The examined unit includes a solar field with flat plate collectors, a high-temperature heat pump, a latent storage system and an organic Rankine cycle. This system is fed by electricity from any renewable energy source (e.g., wind turbines or photovoltaic panels), and so the compressor of the heat pump is driven. The heat pump is fed with low-temperature heat from flat plate collectors, and it rejects heat of medium temperature to a latent storage system. The next step is exploiting the stored heat from an organic Rankine cycle for power production when there is a need for using electricity. The studied system is a ?heat and power to power? system and can lead to high power recovery ratios. The analysis was conducted with a developed mathematical program in Engineering Equation Solver, and it was validated with numerical results from the literature. The optimum storage temperature has been found at 150 ?C and the optimum temperature in the evaporator of the heat pump at 75 ?C. In this case, the electricity recovery ratio (or power to power ratio) is found at 68.48%, the organic Rankine cycle efficiency at 18.45%, and the heat pump coefficient of performance at 3.704, while the collecting area is 150 m2. The use of a similar system without solar collectors but with the ambient as the heat source leads only to a 32.14% power recovery ratio. So, the specific gain of the used collecting area is 35.17 W/m2 which is an important amount of electricity. In the global optimum case, the simple payback period of the solar field investment is found to be at 7.8 years, which is a reasonable value and proves the financial viability of the examined idea. Moreover, this work proves that providing heat input of a relatively high temperature in the heat pump of the pumped thermal energy storage system is an excellent choice for recovering higher amounts of electricity.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] Heat loss and energy efficiency investigation of vacuum flat plate photovoltaic/thermal collectors
    Li, Xue
    Chen, Ken
    Pei, Yu
    Chen, Shuyi
    Zhou, Hai
    Ren, Zhongyi
    Tang, Lin
    Yu, Qiongwan
    Feng, Junsheng
    Pei, Gang
    [J]. Renewable Energy, 2024, 235
  • [22] Optimal process of solar to thermal energy conversion and design of irreversible flat-plate solar collectors
    Torres-Reyes, E
    Navarrete-González, JJ
    Zaleta-Aguilar, A
    Cervantes-de Gortari, JG
    [J]. ENERGY, 2003, 28 (02) : 99 - 113
  • [23] A novel solar-assisted heat pump driven by photovoltaic/thermal collectors: Dynamic simulation and thermoeconomic optimization
    Calise, Francesco
    d'Accadia, Massimo Dentice
    Figaj, Rafal Damian
    Vanoli, Laura
    [J]. ENERGY, 2016, 95 : 346 - 366
  • [24] Design and performance evaluation of a solar-assisted biomass drying system with thermal storage
    Leon, M. Augustus
    Kumar, S.
    [J]. DRYING TECHNOLOGY, 2008, 26 (07) : 936 - 947
  • [25] Thermal performance of a solar-assisted heat pump drying system with thermal energy storage tank and heat recovery unit
    Ismaeel, Hatem Hasan
    Yumrutas, Recep
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2020, 44 (05) : 3426 - 3445
  • [26] Thermal and Electric Storage Optimization for Solar-Assisted Heat Pump Systems in Residential Buildings
    Pinamonti, Maria
    Baggio, Paolo
    [J]. PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 4459 - 4466
  • [27] Energy and cost analysis of processing flat plate solar collectors
    Assad M.E.H.
    Khosravi A.
    Alshabi M.
    Khuwaileh B.
    Hamid A.-K.
    [J]. Energy Engineering: Journal of the Association of Energy Engineering, 2021, 118 (03): : 447 - 458
  • [28] Experimental investigation on the dynamic thermal performance of the parallel solar-assisted air-source heat pump latent heat thermal energy storage system
    Jin, Xin
    Zhang, Huihui
    Huang, Gongsheng
    Lai, Alvin CK.
    [J]. RENEWABLE ENERGY, 2021, 180 : 637 - 657
  • [29] Experimental investigation on thermal performance of flat plate collectors at night
    Tang, Runsheng
    Sun, Zhiguo
    Li, Zhimin
    Yu, Yamei
    Zhong, Hao
    Xia, Chaofeng
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (10) : 2642 - 2646
  • [30] THERMODYNAMIC ANALYSIS OF AN ADVANCED SOLAR-ASSISTED COMPRESSED AIR ENERGY STORAGE SYSTEM
    Udell, Kent
    Beeman, Michael
    [J]. PROCEEDINGS OF THE ASME 10TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2016, VOL 2, 2016,