Impact of Load Variation on the Accuracy of Gait Recognition from Surface EMG Signals

被引:14
|
作者
Zhang, Xianfu [1 ,2 ]
Sun, Shouqian [1 ]
Li, Chao [1 ]
Tang, Zhichuan [3 ]
机构
[1] Zhejiang Univ, Coll Comp Sci & Technol, Hangzhou 310027, Zhejiang, Peoples R China
[2] Wuzhou Univ, Sch Jewelry & Art Design, Wuzhou 543002, Peoples R China
[3] Zhejiang Univ Technol, Ind Design Inst, Hangzhou 310023, Zhejiang, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2018年 / 8卷 / 09期
基金
中国国家自然科学基金;
关键词
sEMG; load variation; gait recognition; lower-limb exoskeletons; MYOELECTRIC CONTROL; MUSCLE-ACTIVITY; UPPER-LIMB; PATTERN-RECOGNITION; LOWER-EXTREMITY; WALKING; BACKPACK; GENDER; SPEED; CLASSIFICATION;
D O I
10.3390/app8091462
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
As lower-limb exoskeleton and prostheses are developed to become smarter and to deploy man-machine collaboration, accurate gait recognition is crucial, as it contributes to the realization of real-time control. Many researchers choose surface electromyogram (sEMG) signals to recognize the gait and control the lower-limb exoskeleton (or prostheses). However, several factors still affect its applicability, of which variation in the loads is an essential one. This study aims to (1) investigate the effect of load variation on gait recognition; and to (2) discuss whether a lower-limb exoskeleton control system trained by sEMG from different loads works well in multi-load applications. In our experiment, 10 male college students were selected to walk on a treadmill at three different speeds (V3 = 3 km/h, V5 = 5 km/h, and V7 = 7 km/h) with four different loads (L0 = 0, L20 = 20%, L30 = 30%, L40 = 40% of body weight, respectively), and 50 gait cycles were performed. Back propagation neural networks (BPNNs) were used for gait recognition, and a support vector machine (SVM) and k-nearest neighbor (k-NN) were used for comparison. The result showed that (1) load variation has significant effects on the accuracy of gait recognition (p < 0.05) under the three speeds when the loads range in L0, L20, L30, or L40, but no significant impact is found when the loads range in L0, L20, or L30. The least significant difference (LSD) post hoc, which can explore all possible pair-wise comparisons of means that comprise a factor using the equivalent of multiple t-tests, reveals that there is a significant difference between the L40 load and the other three loads (L0, L20, L30), but no significant difference was found among the L0, L20, and L30 loads. The total mean accuracy of gait recognition of the intra-loads and inter-loads was 91.81%, and 69.42%, respectively. (2) When the training data was taken from more types of loads, a higher accuracy in gait recognition was obtained at each speed, and the statistical analysis shows that there was a substantial influence for the kinds of loads in the training set on the gait recognition accuracy (p < 0.001). It can be concluded that an exoskeleton (or prosthesis) control system that is trained in a single load or the parts of loads is insufficient in the face of multi-load applications.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Recognition from EMG signals by an evolutional method and non-negative matrix factorization
    Yazama, Y
    Mitsukura, Y
    Fukumi, M
    Akamatsu, N
    KNOWLEDGE-BASED INTELLIGENT INFORMATION AND ENGINEERING SYSTEMS, PT 1, PROCEEDINGS, 2003, 2773 : 594 - 600
  • [42] Self-Correcting Pattern Recognition System of Surface EMG Signals for Upper Limb Prosthesis Control
    Amsuess, Sebastian
    Goebel, Peter M.
    Jiang, Ning
    Graimann, Bernhard
    Paredes, Liliana
    Farina, Dario
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (04) : 1167 - 1176
  • [43] Hand Gesture Recognition for Numbers Based on Machine Vision and Multi-feature Surface EMG Signals
    Li, Zhuotong
    Fu, Xinyuan
    Liu, Peichen
    2021 3RD INTERNATIONAL CONFERENCE ON MACHINE LEARNING, BIG DATA AND BUSINESS INTELLIGENCE (MLBDBI 2021), 2021, : 561 - 567
  • [44] Dynamic Gesture Recognition Using Surface EMG Signals Based on Multi-Stream Residual Network
    Yang, Zhiwen
    Jiang, Du
    Sun, Ying
    Tao, Bo
    Tong, Xiliang
    Jiang, Guozhang
    Xu, Manman
    Yun, Juntong
    Liu, Ying
    Chen, Baojia
    Kong, Jianyi
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [45] Comparison of algorithms estimating linear regression line from surface EMG signals
    Lee, Jin
    Kwon, Hyok-Mok
    Transactions of the Korean Institute of Electrical Engineers, 2008, 57 (03): : 527 - 535
  • [46] ACCURATE CLASSIFICATION OF MOTOR UNIT DISCHARGES FROM DYNAMIC SURFACE EMG SIGNALS
    He, Jinbao
    Luo, Zaifei
    Hu, Qinbo
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2022, 34 (04):
  • [47] Extraction of Elbow Joint Intention from surface EMG Signals in Horizontal Plane
    Song, Quanjun
    Ge, Yunjian
    2008 7TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-23, 2008, : 1931 - 1934
  • [48] Removing ECG noise from surface EMG signals using adaptive filtering
    Lu, Guohua
    Brittain, John-Stuart
    Holland, Peter
    Yianni, John
    Green, Alexander L.
    Stein, John F.
    Aziz, Tipu Z.
    Wang, Shouyan
    NEUROSCIENCE LETTERS, 2009, 462 (01) : 14 - 19
  • [49] MU decomposition from multichannel surface EMG signals using blind deconvolution
    Maekawa, Satoshi
    Arimoto, Takahiko
    Kotani, Manabu
    ELECTRONICS AND COMMUNICATIONS IN JAPAN PART III-FUNDAMENTAL ELECTRONIC SCIENCE, 2007, 90 (02): : 22 - 30
  • [50] Identification of a feature selection based pattern recognition scheme for finger movement recognition from multichannel EMG signals
    Geethanjali Purushothaman
    Raunak Vikas
    Australasian Physical & Engineering Sciences in Medicine, 2018, 41 : 549 - 559