Study on Hardware-in-the-loop Model and Low Voltage Ride-through Characteristics of Photovoltaic Power Station

被引:0
|
作者
Wang, Liqiang [1 ]
Bin Cao [1 ]
Qi Wang [1 ]
Yu Cong [1 ]
Wu, Haiyan [1 ]
Zhang Xiaolin [2 ]
机构
[1] Inner Mongolia Elect Power Res Inst, Inst New Energy Technol, Hohhot, Peoples R China
[2] China Elect Power Res Inst, State Key Lab Operat & Control Renewable Energy &, Beijing, Peoples R China
关键词
photovoltaic power station; low voltage ride-through characteristics; RT-LAB; hardware-in-the-Loop;
D O I
10.1109/egrid48402.2019.9092705
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In order to prevent large-scale disconnection accidents of photovoltaic power stations caused by voltage fluctuations and faults in power grids, low voltage ride-through characteristics and other detection tests are needed when photovoltaic power stations are connected to power grids. At present, field test and type test are the main methods of detection, but due to the limitation of detection devices and test conditions, the evaluation of low voltage ride-through characteristics of photovoltaic power stations still remains in the single-machine detection mode, which ignores the interaction between photovoltaic inverters and inverters, inverters and static var generator(SVG) devices. The test results cannot truly reflect the low voltage traversing characteristics of the photovoltaic power stations. Using RT-LAB hardware-in-the-loop simulation platform, real photovoltaic inverters and SVG controllers are introduced to build simulation models of photovoltaic power stations. The differences between single-machine detection of photovoltaic inverters and reactive power compensation devices and low-voltage ride-through characteristics detection of the whole station are compared and studied. The simulation results show that, compared with the stand-alone test, the whole station simulation modeling test method can reflect the voltage rise caused by the reactive power characteristics of photovoltaic inverters and SVG devices after the drop, and more truly reflect the low voltage traversing characteristics of photovoltaic power stations.
引用
收藏
页码:617 / 620
页数:4
相关论文
共 50 条
  • [41] Low Voltage Ride-through of PV System Based on APFF
    Li, Yan
    He, Darui
    Huang, Xun
    Zhang, Huiyuan
    Lu, Jianghua
    Shen, Yu
    [J]. 2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018, : 812 - 817
  • [42] A ROBUST CONTROL STRATEGY TO IMPROVE LOW VOLTAGE RIDE-THROUGH OF A GRID-CONNECTED PHOTOVOLTAIC SYSTEM
    Ahmed, Abir
    Hazari, Md Rifat
    Jahan, Effat
    Mannan, Mohammad Abdul
    [J]. INTERNATIONAL JOURNAL OF POWER AND ENERGY SYSTEMS, 2021, 41 (01): : 9 - 16
  • [43] The Whole-Process Low-Voltage Ride-Through Control Strategy for Photovoltaic Power Generation Based on Adaptive Maximum Power Tracking
    Yin, Jun
    [J]. FRONTIERS IN ENERGY RESEARCH, 2022, 10
  • [44] Enhanced Computation Performance of Photovoltaic Models for Power Hardware-in-the-Loop Simulation
    Kim, Mina
    Kwak, Sang-Kyu
    Kim, Katherine A.
    Jung, Jee-Hoon
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2021, 68 (08) : 6952 - 6961
  • [45] Microgrid protection considering low voltage ride-through of IIDG
    [J]. Mu, Longhua (lhmu@tongji.edu.cn), 1600, Chinese Society for Electrical Engineering (37):
  • [46] Low-Voltage Ride-Through Simulation for Microgrid Systems
    Foruzan, Elham
    Algrain, Marcelo C.
    Asgarpoor, Sohrab
    [J]. 2017 IEEE INTERNATIONAL CONFERENCE ON ELECTRO INFORMATION TECHNOLOGY (EIT), 2017, : 260 - 264
  • [47] Low Voltage Ride-Through Strategy for Low Voltage Grid by Utilizing Resistance and Inductance
    Boonyapakdee, Nattapon
    Sangswang, Anawach
    Konghirun, Mongkol
    [J]. 2016 19TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2016), 2016,
  • [48] Power Hardware-in-the-Loop Testing of a 500 kW Photovoltaic Array Inverter
    Langston, James
    Schoder, Karl
    Steurer, Mischa
    Faruque, Omar
    Hauer, John
    Bogdan, Ferenc
    Bravo, Richard
    Mather, Barry
    Katiraei, Farid
    [J]. 38TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2012), 2012, : 4797 - 4802
  • [49] Application of Feedback Linearization Strategy in Voltage Fault Ride-through for Photovoltaic Inverters
    Zhang, Yajing
    Ma, Liang
    Zheng, Trillion Q.
    [J]. IECON 2011: 37TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2011,
  • [50] Robust Control of Two-stage Photovoltaic Inverter for Unbalanced Low Voltage Ride-Through Operation
    Tian, Hao
    Gao, Feng
    Ma, Cong
    He, Guoqing
    Li, Guanghui
    [J]. 2014 INTERNATIONAL ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2014, : 560 - 565