摘要
In this paper we report on the design and test of a 14-channel VLSI chip to perform the current to frequency conversion for parallel plate strip ionization chambers. The chambers measure the intensity and the geometrical characteristics of a therapeutical beam. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:111 / 120
页数:10
相关论文
共 50 条
  • [21] CURRENT-TO-FREQUENCY CONVERTER SPANS 140-DB
    SARNS, SE
    EDN, 1987, 32 (23) : 292 - 292
  • [22] A CMOS Based Current-to-Frequency Converter for Current Output Analog Accelerometers
    Nuzumlali, Omer Lutfi
    Eren, Murat
    Kulah, Haluk
    PROCEEDINGS OF THE ION 2013 PACIFIC PNT MEETING, 2013, : 1003 - 1009
  • [23] WIDE-RANGE LINEAR CONVERTER OF CURRENT-FREQUENCY
    KARAPATNITSKII, IA
    KOLCHIN, IV
    UVAROV, II
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1974, (04): : 74 - 76
  • [24] Implementation of a Current-to-voltage Converter with a Wide Dynamic Range
    Park, Jae-Hyoun
    Yoon, Hyung-Do
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2010, 56 (03) : 863 - 867
  • [25] Design of an Energy-Efficient Current-to-Frequency Converter for a Wearable Sensor Platform
    Voulgari, Evgenia
    Krummenacher, Francois
    Kayal, Maher
    PROCEEDINGS OF THE 2019 26TH INTERNATIONAL CONFERENCE MIXED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS (MIXDES 2019), 2019, : 210 - 214
  • [26] L Band to 140 MHz Frequency Converter for wide dynamic range receiver
    Tomar, Seema
    Singh, Sushil Kumar
    PHYSICS OF SEMICONDUCTOR DEVICES, 2014, : 131 - +
  • [27] Implementation of Current-to-Voltage Converter with Wide Dynamic Range and Its Application
    Park, Jae-Hyoun
    Hahn, Cheol-Koo
    Yoon, Hyung-Do
    2009 INTERNATIONAL SOC DESIGN CONFERENCE (ISOCC 2009), 2009, : 500 - 503
  • [28] A 64-channel wide dynamic range charge measurement ASIC for strip and pixel ionization detectors
    Mazza, G
    Cirio, R
    Donetti, M
    La Rosa, A
    Luparia, A
    Marchetto, F
    Peroni, C
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) : 847 - 853
  • [29] A 64-channel wide dynamic range charge measurement ASIC for strip and pixel ionization detectors
    Mazza, G
    Cirio, R
    Donetti, M
    La Rosa, A
    Luparia, A
    Marchetto, F
    Peroni, C
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 964 - 968
  • [30] A Novel Frequency Based Current-to-Digital Converter with Programmable Dynamic Range
    Yu, Xiaoyan
    Farquhar, Ethan
    Blalock, Ben
    53RD IEEE INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS, 2010, : 869 - 872