A novel label-free microfluidic paper-based immunosensor for highly sensitive electrochemical detection of carcinoembryonic antigen

被引:121
|
作者
Wang, Yang [1 ,2 ]
Xu, Huiren [1 ,2 ]
Luo, Jinping [1 ]
Liu, Juntao [1 ]
Wang, Li [1 ,2 ]
Fan, Yan [1 ,2 ]
Yan, Shi [3 ]
Yang, Yue [3 ]
Cai, Xinxia [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst Elect, State Key Lab Transducer Technol, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 10090, Peoples R China
[3] Peking Univ, Canc Hosp & Inst, Key Lab Carcinogenesis & Translat Res, Minist Educ,Dept Thorac Surg 2, Beijing 100142, Peoples R China
来源
关键词
Label-free; Microfluidic paper-based device; Graphene nanocomposites; Screen-printing; CARBON; NANOCOMPOSITES;
D O I
10.1016/j.bios.2016.04.062
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this work, a highly sensitive label-free paper-based electrochemical immunosensor employing screen printed working electrode (SPWE) for detection of carcinoembryonic antigen (CEA) was fabricated. In order to raise the detection sensitivity and immobilize anti-CEA, amino functional graphene (NH2-G)/thionine (Thi)/gold nanoparticles (AuNPs) nanocomposites were synthesized and coated on SPWE. The principle of the immunosensor determination was based on the fact that the decreased response currents of Thi were proportional to the concentrations of corresponding antigens due to the formation of antibody antigen immunocomplex. Experimental results revealed that the immunoassay enabled the determination of standard CEA solutions with linear working ranges of 50 pg mL(-1) to 500 ng mL(-1), the limit of detections for CEA is 10 pg mL(-1) (S/N=3) and its corresponding correlation coefficients were 0.996. Furthermore, the proposed immunosensor could be used for the determination of clinical serum samples. A large number of clinical serum samples were detected and the relative errors between measured values and reference concentrations were calculated. Results showed that this novel paper-based electrochemical immunosensor could provide a new platform for low cost, sensitive, specific, and point-of-care diagnosis in cancer detection. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:319 / 326
页数:8
相关论文
共 50 条
  • [41] A novel ratiometric electrochemical aptasensor for highly sensitive detection of carcinoembryonic antigen
    Wang, Ping
    Xie, Yaoyao
    Ma, Huikai
    Liu, Jiancheng
    Liu, Chenxiang
    Feng, Wei
    Xi, Shoumin
    [J]. ANALYTICAL BIOCHEMISTRY, 2022, 659
  • [42] Label-free photoelectrochemical immunosensor for sensitive detection of Ochratoxin A
    Yang, Jiaojiao
    Gao, Picheng
    Liu, Yixin
    Li, Rongxia
    Ma, Hongmin
    Du, Bin
    Wei, Qin
    [J]. BIOSENSORS & BIOELECTRONICS, 2015, 64 : 13 - 18
  • [43] Label-free impedimetric immunosensor for sensitive detection of ochratoxin A
    Radi, Abd-Elgawad
    Munoz-Berbel, Xavier
    Lates, Vasilica
    Marty, Jean-Louis
    [J]. BIOSENSORS & BIOELECTRONICS, 2009, 24 (07): : 1888 - 1892
  • [44] Label-free electrochemical immunosensor based on flower-like Ag/MoS2/rGO nanocomposites for ultrasensitive detection of carcinoembryonic antigen
    Wang, Yaoguang
    Wang, Yulan
    Wu, Dan
    Ma, Hongmin
    Zhang, Yong
    Fan, Dawei
    Pang, Xuehui
    Du, Bin
    Wei, Qin
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 125 - 132
  • [45] Mucin 4 detection with a label-free electrochemical immunosensor
    Hosu, Oana
    Tertis, Mihaela
    Melinte, Gheorghe
    Feier, Bogdan
    Sandulescu, Robert
    Cristea, Cecilia
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2017, 80 : 39 - 43
  • [46] A label-free electrochemical immunosensor based on gold nanoparticles for detection of paraoxon
    Hu, SQ
    Xie, JW
    Xu, QH
    Rong, KT
    Shen, GL
    Yu, RQ
    [J]. TALANTA, 2003, 61 (06) : 769 - 777
  • [47] A Label-Free Electrochemical Immunosensor Based on AuAgPt NDs Functionalized MoO2 Nanosheets for Highly Sensitive Detection of AFP
    Yang, Qingshan
    Wang, Ping
    Tang, Feng
    Wang, Shujun
    Zhao, Zhe
    Wang, Yao
    Li, Yueyun
    Liu, Qing
    Dong, Yunhui
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (05)
  • [48] A Label-free Electrochemical Immunosensor for Highly Sensitive Detection of TNF α, Based on Star Polymer-modified disposable ITO Electrode
    Aydin, Elif Burcu
    Aydin, Muhammet
    Sezginturk, Mustafa Kemal
    [J]. CURRENT PHARMACEUTICAL ANALYSIS, 2021, 17 (03) : 450 - 459
  • [49] Highly sensitive electrochemical immunosensor based on electrodeposited platinum nanostructures confined in silica nanochannels for the detection of the carcinoembryonic antigen
    Guo, Qinping
    Fan, Xue
    Yan, Fei
    Wang, Yinquan
    [J]. FRONTIERS IN CHEMISTRY, 2023, 11
  • [50] Label-free simultaneous detection of quinolone antibiotic residues using an origami paper–based electrochemical immunosensor
    Chomthong, Kittima
    Kunpatee, Kanjana
    Pimpitak, Umaporn
    Puthong, Songchan
    Komolpis, Kittinan
    Wonsawat, Wanida
    Nuanualsuwan, Suphachai
    Yakoh, Abdulhadee
    Khongchareonporn, Nanthika
    Ruecha, Nipapan
    Chaiyo, Sudkate
    [J]. Sensors and Actuators B: Chemical, 2024, 410