Amorphous silicon, semiconductor X-ray converter detectors for protein crystallography

被引:15
|
作者
Ross, S [1 ]
Zentai, G [1 ]
Shah, KS [1 ]
Alkire, RW [1 ]
Naday, I [1 ]
Westbrook, EM [1 ]
机构
[1] RADIAT MONITORING DEVICES INC,WATERTOWN,MA 02172
关键词
X-ray detector; amorphous silicon; protein crystallography; lead iodide;
D O I
10.1016/S0168-9002(97)00793-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Hydrogenated amorphous silicon (a-Si:H) is a semiconductor material which call be inexpensively deposited to create a large array detector or readout structure. Combining it with a suitable semiconductor X-ray sensitive converter would produce a large, sensitive detector for X-rays with energies of 6-20 keV such as used in measurements of diffraction patterns for protein crystallography. In these experiments, the diffraction patterns created when X-rays strike crystallized protein samples are used to infer the physical structure of the molecules. The requirements for the detector include the ability to record signal peaks to high diffraction order to obtain accurate mapping of the electron density of the protein molecule, plus rapid sampling of the diffraction pattern to minimize radiation dose to the exposed crystal, while maintaining high signal-to-noise ratios. In this paper we summarize our results to date measuring and modeling the suitability of various semiconductor thin films for direct X-ray detection, and of the noise and readout properties of an amorphous silicon matrix array, We provide sample diffraction patterns obtained from a protein crystal taken at the Argonne Advanced Photon Source X-ray synchrotron using a phosphor coated a-Si: H array.
引用
收藏
页码:38 / 50
页数:13
相关论文
共 50 条
  • [21] IMPACT OF SEMICONDUCTOR DETECTORS ON X-RAY SPECTROSCOPY
    WALTER, FJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1970, NS17 (03) : 196 - &
  • [22] EFFICIENCY CALIBRATION OF SEMICONDUCTOR X-RAY DETECTORS
    CAMPBELL, JL
    OBRIEN, P
    MCNELLES, LA
    NUCLEAR INSTRUMENTS & METHODS, 1971, 92 (02): : 269 - &
  • [23] Semiconductor X-ray detectors - Recent developments
    Ponpon, JP
    Siffert, P
    JOURNAL DE PHYSIQUE IV, 1996, 6 (C4): : 703 - 719
  • [24] Substrate and Passivation Techniques for Flexible Amorphous Silicon-Based X-ray Detectors
    Marrs, Michael A.
    Raupp, Gregory B.
    SENSORS, 2016, 16 (08)
  • [25] Estimation of radiation damage of amorphous silicon X-ray detectors by means of a cumulative image
    Brand, BA
    Sonke, JJ
    McDermott, LN
    van Herk, MB
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S73 - S73
  • [26] Industrial protein X-ray crystallography: An overview
    Oliver, JD
    SYNCHROTRON RADIATION TECHNIQUES IN INDUSTRIAL, CHEMICAL AND MATERIALS SCIENCE, 1996, : 1 - 19
  • [27] INDUSTRIAL PROTEIN X-RAY CRYSTALLOGRAPHY - AN OVERVIEW
    OLIVER, JD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 65 - IEC
  • [28] A guide to membrane protein X-ray crystallography
    Kermani, Ali A.
    FEBS JOURNAL, 2021, 288 (20) : 5788 - 5804
  • [29] Protein X-ray Crystallography and Drug Discovery
    Maveyraud, Laurent
    Mourey, Lionel
    MOLECULES, 2020, 25 (05):
  • [30] Effects of nuclear fusion produced neutrons on silicon semiconductor plasma X-ray detectors
    Kohagura, J
    Cho, T
    Hirata, M
    Numakura, T
    Minami, R
    Watanabe, H
    Sasuga, T
    Nishizawa, Y
    Yoshida, A
    Nagashima, S
    Tamano, T
    Yatsu, K
    Miyoshi, S
    Hirano, K
    Maezawa, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3): : 215 - 219