摘要
The continuing advances in computed tomographic (CT) technology in the past decades have provided ongoing opportunities to improve CT image quality and clinical practice and discover new clinical CT imaging applications. New CT technology, however, has introduced new challenges in clinical radiology practice. One of the challenges is with intravenous contrast medium administration and scan timing. In this article, contrast medium pharmacokinetics and patient, contrast medium, and CT scanning factors associated with contrast enhancement and scan timing are presented and discussed. Published data from clinical studies of contrast medium and physiology are reviewed and interpreted. Computer simulation data are analyzed to provide an in-depth analysis of various factors associated with contrast enhancement and scan timing. On the basis of basic principles and analysis of the factors, clinical considerations and modifications to protocol design that are necessary to optimize contrast enhancement for common clinical CT applications are proposed. (C) RSNA, 2010
引用
收藏
页码:32 / 61
页数:30
相关论文
共 50 条
  • [21] PROSTACYCLIN (PGI2) AND THROMBOXANE (TXA2) LEVELS DURING INTRAVENOUS CONTRAST-MEDIUM ADMINISTRATION IN CT
    PAAJANEN, H
    KORMANO, M
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1985, 5 (03) : 243 - 245
  • [22] Determining optimal scan timing in contrast-enhanced CT: Development of a CT number-monitoring system
    Nakaya, Y
    Ozaki, M
    Sekiguchi, R
    Satake, M
    Hirayanagi, N
    Moriyama, N
    [J]. RADIOLOGY, 1996, 201 : 423 - 423
  • [23] OPTIMIZATION AND ADAPTATION OF INTRAVENOUS CONTRAST-MEDIUM DOSAGE IN CT DIAGNOSIS OF THORAX
    EHRITTBRAUN, C
    FERSTL, F
    BURGER, D
    KRAUSE, W
    LANGER, M
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 160 (04): : 364 - 365
  • [24] DOSE OPTIMIZATION OF A NONIONIC INTRAVENOUS CONTRAST-MEDIUM FOR SPIRAL CT OF THE ABDOMEN
    FISHMAN, EK
    ANDERSON, JH
    BROWN, PC
    BLUEMKE, DA
    [J]. RADIOLOGY, 1992, 185 : 114 - 114
  • [25] HEPATIC CONTRAST ENHANCEMENT AT CT - INFLUENCE OF INTRAVENOUS ADMINISTRATION OF GLUCAGON IN A CANINE MODEL
    WARSHAUER, DM
    HIKEN, JN
    MOLINA, PL
    HACKNEY, SL
    BELLINGER, DA
    LEE, JK
    [J]. RADIOLOGY, 1995, 197 : 413 - 413
  • [26] Scan and contrast administration principles of MDCT
    Bae, KT
    Heiken, JP
    [J]. EUROPEAN RADIOLOGY, 2005, 15 : E46 - E59
  • [27] Feasibility of CT scan studies with triple split bolus intravenous contrast medium technique and reduced radiation dose for potential kidney donors Editorial
    Glina, Sidney
    [J]. EINSTEIN-SAO PAULO, 2009, 7 (04): : VII - VIII
  • [28] An Individually Optimized Protocol of Contrast Medium Injection in Enhanced CT Scan for Liver Imaging
    Feng, Shi-Ting
    Zhu, Hongzhang
    Peng, Zhenpeng
    Huang, Li
    Dong, Zhi
    Xu, Ling
    Huang, Kun
    Yang, Xufeng
    Lin, Zhi
    Li, Zi-Ping
    [J]. CONTRAST MEDIA & MOLECULAR IMAGING, 2017,
  • [30] Determination of serum creatinine level before intravenous administration of iodinated contrast medium - A survey
    Lee, JKT
    Warshauer, DM
    Bush, WH
    McClennan, BL
    Choyke, PL
    [J]. INVESTIGATIVE RADIOLOGY, 1995, 30 (12) : 700 - 705