Application of Dielectric Response for Oil-immersed Transformer

被引:0
|
作者
Yang, Shuangsuo [1 ]
Dong, Ming [1 ]
Zhang, Guanjun [1 ]
Zhang, Zhi [2 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat Power Equipment, Xian 71049, Peoples R China
[2] Hubei Elect Power Testing & Res Inst, Wuhan 430077, Peoples R China
关键词
oil-immersed transformer; FDS; insulation; ageing; moisture content; dielectric response; HV POWER EQUIPMENT; FREQUENCY-DOMAIN; SPECTROSCOPY; TIME;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Reliability of large oil-immersed power transformers is attracting more and more attention by the power system, and a lot of new test methods are being under research. In this paper, the dielectric response for oil-immersed transformer insulation condition and ageing diagnosis is introduced; a 220kV transformer was measured utilizing frequency domain spectroscopy in China. The tan delta-f curves of the transformer insulation system before and after maintenance were obtained and compared, respectively The results showed that the dielectric response methods can reflect the internal transformer insulation, estimate moisture content in solid insulation, and provide reference information for the insulation diagnosis. Dielectric response is a non-destructive testing method that can be used as a supplementary technique for the existing diagnosis methods and has good application prospects.
引用
收藏
页码:370 / +
页数:2
相关论文
共 50 条
  • [41] Case Analysis of 220 kV Oil-immersed Current Transformer Defect
    Li Pei
    Li Hongbo
    Niu Lin
    Gao Nannan
    Zhang Yan
    Zhang Yanyan
    Pei Ying
    Yin Qinghua
    [J]. 2020 5TH ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2020), 2020, : 2178 - 2182
  • [42] Experimental study of passive cooling techniques in an oil-immersed transformer building
    Ghafurian, Mohammad Mustafa
    Joveini, Amirhossein
    Safarzadeh, Sajjad
    Niazmand, Hamid
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2023, 148 (24) : 14097 - 14108
  • [43] Fault diagnosis of oil-immersed power transformer by DGA-NN
    Li, Qing-Quan
    Wang, Wei
    Wang, Xiao-Long
    [J]. Gaodianya Jishu/High Voltage Engineering, 2007, 33 (08): : 48 - 51
  • [44] RESEARCH PROGRESS ON INSULATION CONDITION ESTIMATION FOR OIL-IMMERSED POWER TRANSFORMER
    Zhang, Guan-Jun
    Dong, Ming
    Mu, Hai-Bao
    Wei, Jian-Lin
    Yan, Zhang
    [J]. ISEIM 2008: PROCEEDINGS OF 2008 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING, 2008, : 21 - 21
  • [45] Effect of loads on temperature distribution characteristics of oil-immersed transformer winding
    Zhao, Zhengang
    Jiang, Zhangnan
    Li, Yang
    Li, Chuan
    Zhang, Dacheng
    [J]. Distributed Generation and Alternative Energy Journal, 2022, 37 (02): : 237 - 254
  • [46] Synthetic diagnostic method for insulation fault of oil-immersed power transformer
    Qian, Z
    Yang, MZ
    Yan, Z
    [J]. PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 872 - 875
  • [47] Thermal Modeling of an Inverted-Type Oil-Immersed Current Transformer
    Mahajan, Satish M.
    Robalino, Diego M.
    Sivan, Vinod
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (04) : 2511 - 2518
  • [48] Fault diagnosis of oil-immersed transformer based on MGTO-BSCN
    Yi, Lingzhi
    Long, Jiao
    Huang, Jianxiong
    Xu, Xunjian
    Feng, Wenqing
    She, Haixiang
    [J]. JOURNAL OF INTELLIGENT & FUZZY SYSTEMS, 2023, 44 (04) : 6021 - 6034
  • [49] Experimental study of vibration characteristics of 110 kV oil-immersed transformer
    Li, Xiang
    Mo, Juan
    Ma, Yuchao
    Lu, Ling
    [J]. Noise and Vibration Worldwide, 2021, 52 (06): : 145 - 155
  • [50] Effect of Cellulose Nanocrystals on the Performance of Oil-immersed Transformer Insulating Paper
    Chen, Qijie
    Kang, Meicun
    Rong, Zhi
    Zong, Zhangyang
    [J]. BIORESOURCES, 2019, 14 (03) : 6837 - 6850