Biomonitoring occupational sevoflurane exposure at low levels by urinary sevoflurane and hexafluoroisopropanol

被引:10
|
作者
Scapellato, Maria Luisa [1 ]
Carrieri, Mariella [1 ]
Macca, Isabella [1 ]
Salamon, Fabiola [1 ]
Trevisan, Andrea [1 ]
Manno, Maurizio [2 ]
Bartolucci, Giovanni Battista [1 ]
机构
[1] Univ Padua, Dept Cardiol Thorac & Vasc Sci, I-35128 Padua, Italy
[2] Univ Naples Federico II, Dept Publ Hlth, I-80131 Naples, Italy
关键词
Sevoflurane; Hexafluoroisopropanol; Biomarkers; Biological monitoring; Operating room personnel; OPERATING-ROOM PERSONNEL; NITROUS-OXIDE; CYTOCHROME-P450; 2E1; SURGICAL AREAS; PHARMACOKINETICS; IDENTIFICATION; DISPOSITION; ANESTHETICS; ISOFLURANE; METABOLISM;
D O I
10.1016/j.toxlet.2014.10.018
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
This study aimed to correlate environmental sevoflurane levels with urinary concentrations of sevoflurane (Sev-U) or its metabolite hexafluoroisopropanol (HFIP) in order to assess and discuss the main issues relating to which biomarker of sevoflurane exposure is best, and possibly suggest the corresponding biological equivalent exposure limit values. Individual sevoflurane exposure was measured in 100 healthcare operators at five hospitals in north-east Italy using the passive air sampling device Radiello (R), and assaying Sev-U and HFIP concentrations in their urine collected at the end of the operating room session. All analyses were performed by gas chromatography-mass spectrometry. Environmental sevoflurane levels in the operating rooms were also monitored continuously using an infrared photoacoustic analyzer. Our results showed very low individual sevoflurane exposure levels, generally below 0.5 ppm (mean 0.116 ppm; range 0.007-0.940 ppm). Sev-U and HFIP concentrations were in the range of 0.1-17.28 mu g/L and 5-550 mu g/L, respectively. Both biomarkers showed a statistically significant correlation with the environmental exposure levels (Sev-U, r = 0.49; HFIP, r = 0.52), albeit showing fairly scattered values. Sev-U values seem to be influenced by peaks of exposure, especially at the end of the operating-room session, whereas HFIP levels by exposure on the previous day, the data being consistent with the biomarkers' very different half-lives (2.8 and 19 h, respectively). According to our results, both Sev-U and HFIP are appropriate biomarkers for assessing sevoflurane exposure at low levels, although with some differences in times/patterns of exposure. More work is needed to identify the best biomarker of sevoflurane exposure and the corresponding biological equivalent exposure limit values. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:154 / 160
页数:7
相关论文
共 50 条
  • [41] Postoperative Sevoflurane Exposure in the Recovery Room
    Schwaiger, Daniel
    Ruzsanyi, Veronika
    Mayhew, Chris A.
    Lederer, Wolfgang
    JOURNAL OF CRANIOFACIAL SURGERY, 2025, 36 (01) : 346 - 347
  • [42] BIOMONITORING OF LOW-LEVELS OF EXPOSURE TO STYRENE
    GOBBA, F
    GHITTORI, S
    CAVALLERI, A
    AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 1995, 28 (01) : 143 - 145
  • [43] Urinary and air biomonitoring of occupational exposure to benzene in oil pit workers
    Karbasi, Abdolreza
    Khoramnezhadian, Shahrzad
    Zavareh, Saeed Reza Asemi
    Sani, Ghasem Pejman
    HUMAN AND ECOLOGICAL RISK ASSESSMENT, 2020, 26 (02): : 430 - 442
  • [44] Simple assay of plasma sevoflurane and its metabolite hexafluoroisopropanol by headspace GC-MS
    Bourdeaux, Daniel
    Sautou-Miranda, Valerie
    Montagner, Agnes
    Perbet, Sebastien
    Constantin, Jean Michel
    Bazin, Jean-Etienne
    Chopineau, Jean
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (01): : 45 - 50
  • [45] BIOMONITORING OF OCCUPATIONAL TOLUENE EXPOSURE
    APOSTOLI, P
    BRUGNONE, F
    PERBELLINI, L
    COCHEO, V
    BELLOMO, ML
    SILVESTRI, R
    INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1982, 50 (02) : 153 - 168
  • [46] Personnel breathing zone sevoflurane concentration adherence to occupational exposure limits in conjunction with filling of vaporisers
    Heijbel, H.
    Bjurstom, R.
    Jakobsson, J. G.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2010, 54 (09) : 1117 - 1120
  • [47] Metabolic polymorphisms and biomarkers of effect in the biomonitoring of occupational exposure to low-levels of benzene: State of the art
    De Palma, G.
    Manno, M.
    TOXICOLOGY LETTERS, 2014, 231 (02) : 194 - 204
  • [48] Occupational asthma and allergy to sevoflurane and isoflurane in anaesthetic staff
    Vellore, A. D.
    Drought, V. J.
    Sherwood-Jones, D.
    Tunnicliffe, B.
    Moore, V. C.
    Robertson, A. S.
    Burge, P. S.
    ALLERGY, 2006, 61 (12) : 1485 - 1486
  • [49] Biomonitoring of occupational exposure in occupational health: Regulations
    Fontana, L.
    ARCHIVES DES MALADIES PROFESSIONNELLES ET DE L ENVIRONNEMENT, 2012, 73 (03) : 443 - 446
  • [50] Occupational exposure of cashiers to Bisphenol A via thermal paper: urinary biomonitoring study
    Ndaw, Sophie
    Remy, Aurelie
    Jargot, Daniele
    Robert, Alain
    INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2016, 89 (06) : 935 - 946