Biomonitoring occupational sevoflurane exposure at low levels by urinary sevoflurane and hexafluoroisopropanol

被引:10
|
作者
Scapellato, Maria Luisa [1 ]
Carrieri, Mariella [1 ]
Macca, Isabella [1 ]
Salamon, Fabiola [1 ]
Trevisan, Andrea [1 ]
Manno, Maurizio [2 ]
Bartolucci, Giovanni Battista [1 ]
机构
[1] Univ Padua, Dept Cardiol Thorac & Vasc Sci, I-35128 Padua, Italy
[2] Univ Naples Federico II, Dept Publ Hlth, I-80131 Naples, Italy
关键词
Sevoflurane; Hexafluoroisopropanol; Biomarkers; Biological monitoring; Operating room personnel; OPERATING-ROOM PERSONNEL; NITROUS-OXIDE; CYTOCHROME-P450; 2E1; SURGICAL AREAS; PHARMACOKINETICS; IDENTIFICATION; DISPOSITION; ANESTHETICS; ISOFLURANE; METABOLISM;
D O I
10.1016/j.toxlet.2014.10.018
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
This study aimed to correlate environmental sevoflurane levels with urinary concentrations of sevoflurane (Sev-U) or its metabolite hexafluoroisopropanol (HFIP) in order to assess and discuss the main issues relating to which biomarker of sevoflurane exposure is best, and possibly suggest the corresponding biological equivalent exposure limit values. Individual sevoflurane exposure was measured in 100 healthcare operators at five hospitals in north-east Italy using the passive air sampling device Radiello (R), and assaying Sev-U and HFIP concentrations in their urine collected at the end of the operating room session. All analyses were performed by gas chromatography-mass spectrometry. Environmental sevoflurane levels in the operating rooms were also monitored continuously using an infrared photoacoustic analyzer. Our results showed very low individual sevoflurane exposure levels, generally below 0.5 ppm (mean 0.116 ppm; range 0.007-0.940 ppm). Sev-U and HFIP concentrations were in the range of 0.1-17.28 mu g/L and 5-550 mu g/L, respectively. Both biomarkers showed a statistically significant correlation with the environmental exposure levels (Sev-U, r = 0.49; HFIP, r = 0.52), albeit showing fairly scattered values. Sev-U values seem to be influenced by peaks of exposure, especially at the end of the operating-room session, whereas HFIP levels by exposure on the previous day, the data being consistent with the biomarkers' very different half-lives (2.8 and 19 h, respectively). According to our results, both Sev-U and HFIP are appropriate biomarkers for assessing sevoflurane exposure at low levels, although with some differences in times/patterns of exposure. More work is needed to identify the best biomarker of sevoflurane exposure and the corresponding biological equivalent exposure limit values. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:154 / 160
页数:7
相关论文
共 50 条
  • [1] Urinary sevoflurane and hexafluoro-isopropanol as biomarkers of low-level occupational exposure to sevoflurane
    Antonio Accorsi
    Barbara Morrone
    Irene Domenichini
    Simona Valenti
    Giovanni Battista Raffi
    Francesco Saverio Violante
    International Archives of Occupational and Environmental Health, 2005, 78 : 369 - 378
  • [2] Urinary sevoflurane and hexafluoro-isopropanol as biomarkers of low-level occupational exposure to sevoflurane
    Accorsi, A
    Morrone, B
    Domenichini, I
    Valenti, S
    Raffi, GB
    Violante, FS
    INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2005, 78 (05) : 369 - 378
  • [3] The Personnel's Sevoflurane Exposure in the Postanesthesia Care Unit Measured by Photoacoustic Gas Monitoring and Hexafluoroisopropanol Biomonitoring
    Herzog-Niescery, Jennifer
    Vogelsang, Heike
    Bellgardt, Martin
    Seipp, Hans-Martin
    Weber, Thomas P.
    Gude, Philipp
    JOURNAL OF PERIANESTHESIA NURSING, 2019, 34 (03) : 606 - 613
  • [4] Proposal for single and mixture biological exposure limits for sevoflurane and nitrous oxide at low occupational exposure levels
    Accorsi, A
    Valenti, S
    Barbieri, A
    Raffi, GB
    Violante, FS
    INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2003, 76 (02) : 129 - 136
  • [5] Proposal for single and mixture biological exposure limits for sevoflurane and nitrous oxide at low occupational exposure levels
    Antonio Accorsi
    Simona Valenti
    Anna Barbieri
    Giovanni Raffi
    Francesco Violante
    International Archives of Occupational and Environmental Health, 2003, 76 : 129 - 136
  • [6] Anesthetics (sevoflurane) biomonitoring: Urinary hexafluoroisopropanolol removal kinetics
    Barbic, F
    Bagnati, M
    Basile, M
    Zanoli, V
    Cassani, C
    Porta, P
    Fortina, A
    Mantovani, C
    Bellomo, G
    Colosio, C
    TOXICOLOGY AND APPLIED PHARMACOLOGY, 2004, 197 (03) : 324 - 324
  • [7] Occupational exposure to sevoflurane during conscious sedation
    Hoerauf, KH
    Ledez, K
    ANESTHESIOLOGY, 1999, 91 (3A) : U463 - U463
  • [8] Occupational exposure to sevoflurane during cardiopulmonary bypass
    Blokker-Veldhuis, M. J.
    Rutten, P. M. M. J.
    De Hert, S. G.
    PERFUSION-UK, 2011, 26 (05): : 383 - 389
  • [9] Determination of hexafluoroisopropanol, a sevoflurane urinary metabolite, by 9-fluorenylmethyl chloroformate derivatization
    Buratti, M
    Valla, C
    Xaiz, D
    Brambilla, G
    Colombi, A
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 776 (02): : 237 - 243
  • [10] URINARY-EXCRETION OF HEXAFLUOROISOPROPANOL GLUCURONIDE AND FLUORIDE IN PATIENTS AFTER SEVOFLURANE ANESTHESIA
    NI, JX
    SATO, N
    FUJII, K
    YUGE, O
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 1993, 45 (01) : 67 - 69