Numerical Simulation of Heat Transfer Performance of Micro-heat Pipe Array based on FLUENT

被引:1
|
作者
Yang, Jingang [1 ,2 ]
Yu, Tianmiao
Wei, Sinan
Wang, Xinpeng
机构
[1] Beijing Univ Technol, Beijing 100124, Peoples R China
[2] Jilin Jianzhu Univ, Changchun 130021, Jilin, Peoples R China
关键词
D O I
10.1088/1755-1315/295/3/032004
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The structure and basic principle of heat pipe and plate micro heat pipe array are introduced in detail, and the application of FLUENT grid technology and numerical technique is introduced. The thermal conductivity, the phase change and the effect of the liquid filling rate on the heat transfer performance of the heat pipe were simulated by using FLUENT of CFD software. The results show that when the liquid filling rate is 20% similar to 30%, the thermal conductivity of the micro heat pipe starts to rise, reaching 6.11 x 10-5 W . m-2 at the highest level. When the liquid filling rate of 30% to 40%, the thermal conductivity of the micro-heat pipe began to decline, which indicates that the best filling rate is when the liquid filling rate is 20 similar to 30. When the temperature of the outer wall of the condensation section is 67.5 degrees C, the maximum heat flux can reach 8.1 x 105 W x m-2.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Numerical investigation of the thermal performance enhancement of latent heat thermal energy storage using longitudinal rectangular fins and flat micro-heat pipe arrays
    Diao, Y. H.
    Liang, L.
    Zhao, Y. H.
    Wang, Z. Y.
    Bai, F. W.
    APPLIED ENERGY, 2019, 233 : 894 - 905
  • [42] Study on the Heat Storage and Release Performance of the Electrical Phase Change Storage Heater With Flat Micro-heat Pipe Arrays
    Zhang, Yubin
    Diao, Yanhua
    Zhao, Yaohua
    Wang, Zeyu
    Liang, Lin
    Chen, Chuanqi
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2023, 44 (06): : 1675 - 1680
  • [43] Experimental Study on Heat Transfer Performance of Micro-Channel Heat Pipe
    Zhang, Yaping
    Li, Chenlong
    Cui, Xingke
    Hu, Mengge
    Jiang, Haochen
    HEAT TRANSFER ENGINEERING, 2025,
  • [44] Experimental investigation on the performance of a novel solar air heater based on flat micro-heat pipe arrays (FMHPA)
    Zhu, Ting-ting
    Zhao, Yao-hua
    Diao, Yan-hua
    Li, Feng-fei
    Deng, Yue-chao
    INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY, SHC 2014, 2015, 70 : 146 - 154
  • [45] Numerical simulation of start-up characteristics and heat transfer performance of ultra-thin heat pipe
    Shi F.
    Gan Y.
    Huagong Xuebao/CIESC Journal, 2023, 74 (07): : 2814 - 2823
  • [46] Numerical simulation study on heat transfer performance of double U-shaped buried pipe heat exchanger
    Ren, Yucheng
    Liu, Zhipeng
    Gao, Xiaocong
    Liu, Wenlong
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2024,
  • [47] Heat transfer performance test and numerical simulation of pile-pipe ground source heat pump system
    Institute of HVAC and GAS Engineering, Tongji University, Shanghai 200092, China
    Taiyangneng Xuebao, 2009, 6 (727-731):
  • [48] Design and numerical simulation of the effect of heat transfer on the micro centrifugal compressor performance
    Shen, Yu-Xin
    Liu, Jian-Jun
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2010, 25 (04): : 897 - 901
  • [49] Experimental investigation on the thermal performance of Si micro-heat pipe with different cross-sections
    Hamidnia, Mohammad
    Luo, Yi
    Wang, Xiaodong
    Li, Congming
    MODERN PHYSICS LETTERS B, 2017, 31 (30):
  • [50] Numerical simulation of thermal performance and temperature field in heat pipe heat exchanger
    Sun, Shimei
    Zhang, Hong
    Huagong Xuebao/Journal of Chemical Industry and Engineering (China), 2004, 55 (03): : 472 - 475