Numerical Simulation of Heat Transfer Performance of Micro-heat Pipe Array based on FLUENT

被引:1
|
作者
Yang, Jingang [1 ,2 ]
Yu, Tianmiao
Wei, Sinan
Wang, Xinpeng
机构
[1] Beijing Univ Technol, Beijing 100124, Peoples R China
[2] Jilin Jianzhu Univ, Changchun 130021, Jilin, Peoples R China
关键词
D O I
10.1088/1755-1315/295/3/032004
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The structure and basic principle of heat pipe and plate micro heat pipe array are introduced in detail, and the application of FLUENT grid technology and numerical technique is introduced. The thermal conductivity, the phase change and the effect of the liquid filling rate on the heat transfer performance of the heat pipe were simulated by using FLUENT of CFD software. The results show that when the liquid filling rate is 20% similar to 30%, the thermal conductivity of the micro heat pipe starts to rise, reaching 6.11 x 10-5 W . m-2 at the highest level. When the liquid filling rate of 30% to 40%, the thermal conductivity of the micro-heat pipe began to decline, which indicates that the best filling rate is when the liquid filling rate is 20 similar to 30. When the temperature of the outer wall of the condensation section is 67.5 degrees C, the maximum heat flux can reach 8.1 x 105 W x m-2.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Numerical investigation on heat transfer of vertical micro-heat pipe arrays
    Wang, H. (wanghongyan@bjut.edu.cn), 1600, Materials China (65):
  • [2] Heat transfer performance of a micro heat pipe array filled with copper foam
    Wang, Lincheng
    Quan, Zhenhua
    Xu, Hongxia
    Guo, Hang
    Zhao, Yaohua
    APPLIED THERMAL ENGINEERING, 2025, 269
  • [3] Assessing the performance of a gas-water heat exchanger based on micro-heat pipe technology
    Jingang, Yang
    Hao, Wang
    Jialu, Lv
    EXPERIMENTAL HEAT TRANSFER, 2023, 36 (06) : 892 - 917
  • [4] A numerical study on performance optimization of a micro-heat pipe arrays-based solar air heater
    Zhu, Tingting
    Zhang, Ji
    ENERGY, 2021, 215
  • [5] An analytical model for fluid flow and heat transfer in a micro-heat pipe of polygonal shape
    Suman, B
    Kumar, P
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (21-22) : 4498 - 4509
  • [6] Heat transfer performance of flat micro-heat pipe with sintered multi-size copper powder wick
    Zhao, Zhengang
    Peng, Guohong
    Zhang, Yanhui
    Zhang, Dacheng
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 42
  • [7] Experimental study on the heat recovery characteristic of a heat exchanger based on a flat micro-heat pipe array for the ventilation of residential buildings
    Diao, Y. H.
    Liang, L.
    Kang, Y. M.
    Zhao, Y. H.
    Wang, Z. Y.
    Zhu, T. T.
    ENERGY AND BUILDINGS, 2017, 152 : 448 - 457
  • [8] Heat transfer performance of a micro heat pipe array for battery thermal management systems
    Yao, Chengning
    Dan, Dan
    Zhang, Yangjun
    Wang, Yuegi
    Qian, Yuping
    Zhuge, Weilin
    CHINESE SCIENCE BULLETIN-CHINESE, 2020, 65 (31): : 3485 - 3496
  • [9] THERMAL-ANALYSIS OF A MICRO-HEAT PIPE
    KHRUSTALEV, D
    FAGHRI, A
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1994, 116 (01): : 189 - 198
  • [10] Experimental study on the thermal performance of a new type of thermal energy storage based on flat micro-heat pipe array
    Li, Feng-fei
    Diao, Yan-hua
    Zhao, Yao-hua
    Zhu, Ting-ting
    Liu, Jing
    ENERGY CONVERSION AND MANAGEMENT, 2016, 112 : 395 - 403