Implantable Hemodynamic Monitoring for Heart Failure Patients

被引:88
|
作者
Abraham, William T. [1 ,2 ,3 ,4 ]
Perl, Leor [5 ,6 ,7 ]
机构
[1] Ohio State Univ, Dept Med, Div Cardiovasc Med, 473 West 12th Ave,Suite 110P, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Physiol, Div Cardiovasc Med, 473 West 12th Ave,Suite 110P, Columbus, OH 43210 USA
[3] Ohio State Univ, Dept Cell Biol, Div Cardiovasc Med, 473 West 12th Ave,Suite 110P, Columbus, OH 43210 USA
[4] Ohio State Univ, Davis Heart & Lung Res Inst, 473 West 12th Ave,Suite 110P, Columbus, OH 43210 USA
[5] Rabin Med Ctr, Cardiol Dept, Petah Tiqwa, Israel
[6] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
[7] Stanford Univ, Med Ctr, Div Cardiovasc Med, Stanford, CA 94305 USA
关键词
disease management; hospitalization; patient readmission; pulmonary artery pressure; telemedicine; LEFT-ATRIAL PRESSURE; PULMONARY-ARTERY PRESSURE; SIDED FILLING PRESSURES; END-DIASTOLIC PRESSURE; MITRAL REGURGITATION; NATRIURETIC PEPTIDES; MANAGEMENT; HOSPITALIZATIONS; DISEASE; HYPERTENSION;
D O I
10.1016/j.jacc.2017.05.052
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Rates of heart failure hospitalization remain unacceptably high. Such hospitalizations are associated with substantial patient, caregiver, and economic costs. Randomized controlled trials of noninvasive telemedical systems have failed to demonstrate reduced rates of hospitalization. The failure of these technologies may be due to the limitations of the signals measured. Intracardiac and pulmonary artery pressure-guided management has become a focus of hospitalization reduction in heart failure. Early studies using implantable hemodynamic monitors demonstrated the potential of pressure-based heart failure management, whereas subsequent studies confirmed the clinical utility of this approach. One large pivotal trial proved the safety and efficacy of pulmonary artery pressure-guided heart failure management, showing a marked reduction in heart failure hospitalizations in patients randomized to active pressure-guided management. "Next-generation" implantable hemodynamic monitors are in development, and novel approaches for the use of this data promise to expand the use of pressure-guided heart failure management. (C) 2017 by the American College of Cardiology Foundation.
引用
收藏
页码:389 / 398
页数:10
相关论文
共 50 条
  • [41] Implantable hemodynamic monitoring devices
    Seifert, M.
    Butter, C.
    [J]. HERZ, 2015, 40 (07) : 966 - 971
  • [42] Management of the Patient with Heart Failure and an Implantable Pulmonary Artery Hemodynamic Sensor
    Abraham, Jacob
    McCann, Patrick J.
    Guglin, Maya E.
    Bhimaraj, Arvind
    Benjamin, Terrie-Ann S.
    Robinson, Monique R.
    Jonsson, Orvar T.
    Feitell, Scott C.
    Bhatt, Kunjan A.
    Bennett, Mosi K.
    Heywood, J. T.
    [J]. CURRENT CARDIOVASCULAR RISK REPORTS, 2020, 14 (09)
  • [43] Implant experience with an implantable hemodynamic monitor for the management of symptomatic heart failure
    Steinhaus, D
    Reynolds, DW
    Gadler, F
    Kay, GN
    Hess, MF
    Bennett, T
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (08): : 747 - 753
  • [44] Management of the Patient with Heart Failure and an Implantable Pulmonary Artery Hemodynamic Sensor
    Jacob Abraham
    Patrick J. McCann
    Maya E. Guglin
    Arvind Bhimaraj
    Terrie-Ann S. Benjamin
    Monique R. Robinson
    Orvar T. Jonsson
    Scott C. Feitell
    Kunjan A. Bhatt
    Mosi K. Bennett
    J.T. Heywood
    [J]. Current Cardiovascular Risk Reports, 2020, 14
  • [45] Hemodynamic monitoring using wireless implantable sensor (CardioMEMS) in patients with heart failure First experience in Latin America post approval for clinical use
    Navarrete Hurtado, Solon
    Brecci, Miguel
    Riveros, Fernando
    Lemus Barrios, Gustavo
    Amado, Luisa
    Mera, Katalina
    [J]. INSUFICIENCIA CARDIACA, 2018, 13 (03) : 134 - 144
  • [46] Hemodynamic Monitoring to Guide Treatment of Acute Heart Failure
    Givertz, Michael M.
    [J]. JOURNAL OF CARDIAC FAILURE, 2011, 17 (09) : 726 - 728
  • [47] Continuous Noninvasive Hemodynamic Monitoring in Decompensated Heart Failure
    Lima, Marcelo Villaca
    Ochiai, Marcelo Eidi
    Vieira, Kelly Novaes
    Cardoso, Juliano Novaes
    Brancalhao, Euler Cristovan
    Puig, Raphael
    Pereira Barretto, Antonio Carlos
    [J]. ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2012, 99 (03) : 843 - 847
  • [48] Hemodynamic Monitoring in the Acute Management of Pediatric Heart Failure
    Tsang, Rocky
    Checchia, Paul
    Bronicki, Ronald A.
    [J]. CURRENT CARDIOLOGY REVIEWS, 2016, 12 (02) : 112 - 116
  • [49] Intracardiac Pressures Measured Using an Implantable Hemodynamic Monitor: Relationship to Mortality in Patients With Chronic Heart Failure
    El Hajj, Stephanie
    Bennett, Tom D.
    Zile, Michael R.
    Kueffer, Fred J.
    Baicu, Catalin F.
    Abraham, William T.
    Bourge, Robert C.
    Stevenson, Lynne
    [J]. CIRCULATION, 2016, 134
  • [50] Intracardiac Pressures Measured Using an Implantable Hemodynamic Monitor: Relationship to Mortality in Patients With Chronic Heart Failure
    El Hajj, Stephanie
    Bennett, Tom D.
    Zile, Michael R.
    Kueffer, Fred J.
    Baicu, Catalin F.
    Abraham, William T.
    Bourge, Robert C.
    Stevenson, Lynne
    [J]. CIRCULATION, 2016, 134