Estimated risk of radiation-induced cancer following breast screening employing tomosynthesis and digital mammography

被引:1
|
作者
Alves, Marcos S. [1 ]
Ferro, Ana G. L. [1 ]
Moreira, Marcia C. L. [1 ]
Santos, William S. [2 ]
Neves, Lucio P. [2 ,3 ]
Perini, Ana P. [2 ,3 ]
Belinato, Walmir [4 ]
Souza, Divanizia N. [1 ]
机构
[1] Univ Fed Sergipe, Dept Fis, Sao Cristovao, SE, Brazil
[2] Univ Fed Uberlandia, Inst Fis, Uberlandia, MG, Brazil
[3] Univ Fed Uberlandia, Programa Posgrad Engn Biomed, Fac Engn Eletr, Uberlandia, MG, Brazil
[4] Inst Fed Bahia IFBA, Vitoria Da Conquista, BA, Brazil
关键词
radiation-induced cancer; breast; screenings; Monte Carlo simulations; tomosynthesis; MONTE-CARLO SIMULATIONS; FEMALE;
D O I
10.1088/1361-6498/abdfd8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objective of this study was to estimate the risk of radiation-induced injury to the organs due to ionizing radiation following breast screening recommendations employing digital breast tomosynthesis (DBT) and digital mammography (DM). Using the Monte Carlo method, absorbed doses in the tissues and organs were calculated on an adult female phantom, considering two-view craniocaudal (CC) and mediolateral oblique (MLO) projections for each breast. The results showed differences in the total effective risk due to DM (CC + MLO) and DBT (CC + MLO) examinations in Brazil, ranging from 20.73 cases 10(-5) (DM) to 27.19 cases 10(-5) (DBT). Significant differences were also observed in the total effective risk of cancer incidence in the lungs due to DM (CC + MLO) and DBT (CC + MLO), ranging from 1.75x10(-01) cases 10(-5) (DM) to 1.76x10(-01) cases 10(-5) (DBT). The results indicate that the total effective risk of incidence should be considered as an additional parameter for the evaluation of DBT or DBT + DM program performance.
引用
收藏
页码:254 / 265
页数:12
相关论文
共 50 条
  • [1] Breast Cancer Screening With Tomosynthesis and Digital Mammography
    Seidenwurm, David
    Rosenberg, Robert
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 312 (16): : 1695 - 1695
  • [2] BREAST TOMOSYNTHESIS OR DIGITAL MAMMOGRAPHY FOR BREAST CANCER SCREENING?
    Svahn, Tony
    [J]. MEDICAL PHYSICS IN THE BALTIC STATES, 2011, : 53 - 56
  • [3] ESTIMATED RISK OF RADIATION-INDUCED BREAST CANCER FROM MAMMOGRAPHIC SCREENING
    Freitas-Junior, R.
    Correa, R. S.
    Peixoto, J-E
    Ferreira, R. S.
    Tanaka, R. I. M.
    [J]. CANCER RESEARCH, 2012, 72
  • [4] Digital Mammography versus Digital Mammography Plus Tomosynthesis in Breast Cancer Screening: The Oslo Tomosynthesis Screening Trial
    Skaane, Per
    Bandos, Andriy L.
    Niklason, Loren T.
    Sebuodegard, Sofie
    Osteras, Bjorn H.
    Gullien, Randi
    Gur, David
    Hofvind, Solveig
    [J]. RADIOLOGY, 2019, 291 (01) : 22 - 29
  • [5] Mathematical modelling of radiation-induced cancer risk from breast screening by mammography
    Ali, Raed M. K. M.
    England, Andrew
    Mercer, Claire
    Tootell, Andrew
    Walton, Lucy
    Schaake, Wouter
    Hogg, Peter
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2017, 96 : 98 - 103
  • [6] Addition of Screening Breast US to Digital Mammography and Digital Breast Tomosynthesis for Breast Cancer Screening in Women at Average Risk
    Yi, Ann
    Jang, Myoung-jin
    Yim, Dahae
    Kwon, Bo Ra
    Shin, Sung Ui
    Chang, Jung Min
    [J]. RADIOLOGY, 2021, 298 (03) : 568 - 575
  • [7] Breast Cancer Screening via Digital Mammography, Synthetic Mammography, and Tomosynthesis
    Cohen, Ethan O.
    Weaver, Olena O.
    Tso, Hilda H.
    Gerlach, Karen E.
    Leung, Jessica W. T.
    [J]. AMERICAN JOURNAL OF PREVENTIVE MEDICINE, 2020, 58 (03) : 470 - 472
  • [8] Breast Cancer Screening with Digital Breast Tomosynthesis Improves Performance of Mammography Screening
    Bae, Min Sun
    Seo, Bo Kyoung
    [J]. RADIOLOGY, 2023, 307 (03)
  • [9] Comparison of Tomosynthesis Plus Digital Mammography and Digital Mammography Alone for Breast Cancer Screening
    Haas, Brian M.
    Kalra, Vivek
    Geisel, Jaime
    Raghu, Madhavi
    Durand, Melissa
    Philpotts, Liane E.
    [J]. RADIOLOGY, 2013, 269 (03) : 694 - 700
  • [10] Breast Cancer Screening Using Tomosynthesis in Combination With Digital Mammography
    Friedewald, Sarah M.
    Rafferty, Elizabeth A.
    Rose, Stephen L.
    Durand, Melissa A.
    Plecha, Donna M.
    Greenberg, Julianne S.
    Hayes, Mary K.
    Copit, Debra S.
    Carlson, Kara L.
    Cink, Thomas M.
    Barke, Lora D.
    Greer, Linda N.
    Miller, Dave P.
    Conant, Emily F.
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 311 (24): : 2499 - 2507