Breast Cancer Screening Using Tomosynthesis in Combination With Digital Mammography

被引:611
|
作者
Friedewald, Sarah M. [1 ]
Rafferty, Elizabeth A. [2 ]
Rose, Stephen L. [3 ,4 ]
Durand, Melissa A. [5 ]
Plecha, Donna M. [6 ]
Greenberg, Julianne S. [7 ]
Hayes, Mary K. [8 ,9 ]
Copit, Debra S. [10 ]
Carlson, Kara L. [11 ,12 ]
Cink, Thomas M. [13 ]
Barke, Lora D. [14 ,15 ]
Greer, Linda N. [16 ]
Miller, Dave P. [17 ]
Conant, Emily F. [18 ]
机构
[1] Advocate Lutheran Gen Hosp, Ctr Adv Care, Caldwell Breast Ctr, Park Ridge, IL 60068 USA
[2] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[3] TOPS Comprehens Breast Ctr, Houston, TX USA
[4] Solis Womens Hlth, Dallas, TX USA
[5] Yale Univ, Sch Med, Dept Diagnost Radiol, Breast Imaging Sect, New Haven, CT 06510 USA
[6] Univ Hosp Case Med Ctr, Dept Radiol, Cleveland, OH USA
[7] Washington Radiol Associates, Fairfax, VA USA
[8] Radiol Associates Hollywood, Hollywood, FL USA
[9] Mem Healthcare Syst, Hollywood, FL USA
[10] Albert Einstein Healthcare Network, Dept Diagnost Radiol, Philadelphia, PA USA
[11] Evergreen Hlth Breast Ctr, Kirkland, WA USA
[12] Radia Inc, Kirkland, WA USA
[13] Edith Sanford Breast Hlth Inst, Sioux Falls, SD USA
[14] Invis Sally Jobe Breast Ctr, Denver, CO USA
[15] Radiol Imaging Associates, Denver, CO USA
[16] John C Lincoln Breast Hlth & Res Ctr, Phoenix, AZ USA
[17] ICON Clin Res, San Francisco, CA USA
[18] Univ Penn, Dept Radiol, Perelman Sch Med, Philadelphia, PA 19104 USA
来源
关键词
PERFORMANCE; POPULATION; TRIAL;
D O I
10.1001/jama.2014.6095
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IMPORTANCE Mammography plays a key role in early breast cancer detection. Single-institution studies have shown that adding tomosynthesis to mammography increases cancer detection and reduces false-positive results. OBJECTIVE To determine if mammography combined with tomosynthesis is associated with better performance of breast screening programs in the United States. DESIGN, SETTING, AND PARTICIPANTS Retrospective analysis of screening performance metrics from 13 academic and nonacademic breast centers using mixed models adjusting for site as a random effect. EXPOSURES Period 1: digital mammography screening examinations 1 year before tomosynthesis implementation (start dates ranged from March 2010 to October 2011 through the date of tomosynthesis implementation); period 2: digital mammography plus tomosynthesis examinations from initiation of tomosynthesis screening (March 2011 to October 2012) through December 31, 2012. MAIN OUTCOMES AND MEASURES Recall rate for additional imaging, cancer detection rate, and positive predictive values for recall and for biopsy. RESULTS A total of 454 850 examinations (n = 281 187 digital mammography; n = 173 663 digital mammography + tomosynthesis) were evaluated. With digital mammography, 29 726 patients were recalled and 5056 biopsies resulted in cancer diagnosis in 1207 patients (n = 815 invasive; n = 392 in situ). With digital mammography + tomosynthesis, 15 541 patients were recalled and 3285 biopsies resulted in cancer diagnosis in 950 patients (n = 707 invasive; n = 243 in situ). Model-adjusted rates per 1000 screens were as follows: for recall rate, 107 (95% CI, 89-124) with digital mammography vs 91 (95% CI, 73-108) with digital mammography + tomosynthesis; difference, -16 (95% CI, -18 to -14; P < .001); for biopsies, 18.1 (95% CI, 15.4-20.8) with digital mammography vs 19.3 (95% CI, 16.6-22.1) with digital mammography + tomosynthesis; difference, 1.3 (95% CI, 0.4-2.1; P = .004); for cancer detection, 4.2 (95% CI, 3.8-4.7) with digital mammography vs 5.4 (95% CI, 4.9-6.0) with digital mammography + tomosynthesis; difference, 1.2 (95% CI, 0.8-1.6; P < .001); and for invasive cancer detection, 2.9 (95% CI, 2.5-3.2) with digital mammography vs 4.1 (95% CI, 3.7-4.5) with digital mammography + tomosynthesis; difference, 1.2 (95% CI, 0.8-1.6; P < .001). The in situ cancer detection rate was 1.4 (95% CI, 1.2-1.6) per 1000 screens with both methods. Adding tomosynthesis was associated with an increase in the positive predictive value for recall from 4.3% to 6.4%(difference, 2.1%; 95% CI, 1.7%-2.5%; P < .001) and for biopsy from 24.2% to 29.2%(difference, 5.0%; 95% CI, 3.0%-7.0%; P < .001). CONCLUSIONS AND RELEVANCE Addition of tomosynthesis to digital mammography was associated with a decrease in recall rate and an increase in cancer detection rate. Further studies are needed to assess the relationship to clinical outcomes.
引用
收藏
页码:2499 / 2507
页数:9
相关论文
共 50 条
  • [1] Effect of age on breast cancer screening using tomosynthesis in combination with digital mammography
    Elizabeth A. Rafferty
    Stephen L. Rose
    Dave P. Miller
    Melissa A. Durand
    Emily F. Conant
    Debra S. Copit
    Sarah M. Friedewald
    Donna M. Plecha
    Ingrid L. Ott
    Mary K. Hayes
    Kara L. Carlson
    Thomas M. Cink
    Lora D. Barke
    Linda N. Greer
    Loren T. Niklason
    [J]. Breast Cancer Research and Treatment, 2017, 164 : 659 - 666
  • [2] Effect of age on breast cancer screening using tomosynthesis in combination with digital mammography
    Rafferty, Elizabeth A.
    Rose, Stephen L.
    Miller, Dave P.
    Durand, Melissa A.
    Conant, Emily F.
    Copit, Debra S.
    Friedewald, Sarah M.
    Plecha, Donna M.
    Ott, Ingrid L.
    Hayes, Mary K.
    Carlson, Kara L.
    Cink, Thomas M.
    Barke, Lora D.
    Greer, Linda N.
    Niklason, Loren T.
    [J]. BREAST CANCER RESEARCH AND TREATMENT, 2017, 164 (03) : 659 - 666
  • [3] Breast Cancer Screening With Tomosynthesis and Digital Mammography
    Seidenwurm, David
    Rosenberg, Robert
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 312 (16): : 1695 - 1695
  • [4] BREAST TOMOSYNTHESIS OR DIGITAL MAMMOGRAPHY FOR BREAST CANCER SCREENING?
    Svahn, Tony
    [J]. MEDICAL PHYSICS IN THE BALTIC STATES, 2011, : 53 - 56
  • [5] Digital Mammography versus Digital Mammography Plus Tomosynthesis in Breast Cancer Screening: The Oslo Tomosynthesis Screening Trial
    Skaane, Per
    Bandos, Andriy L.
    Niklason, Loren T.
    Sebuodegard, Sofie
    Osteras, Bjorn H.
    Gullien, Randi
    Gur, David
    Hofvind, Solveig
    [J]. RADIOLOGY, 2019, 291 (01) : 22 - 29
  • [6] Breast Cancer Screening Using Digital Breast Tomosynthesis Not All Mammography Is Equal
    Bahl, Manisha
    Lehman, Constance D.
    [J]. JAMA ONCOLOGY, 2019, 5 (05) : 642 - 643
  • [7] Multicenter Evaluation of Breast Cancer Screening with Digital Breast Tomosynthesis in Combination with Synthetic versus Digital Mammography
    Zuckerman, Samantha P.
    Sprague, Brian L.
    Weaver, Donald L.
    Herschorn, Sally D.
    Conant, Emily F.
    [J]. RADIOLOGY, 2020, 297 (03) : 545 - 553
  • [8] Breast Cancer Screening via Digital Mammography, Synthetic Mammography, and Tomosynthesis
    Cohen, Ethan O.
    Weaver, Olena O.
    Tso, Hilda H.
    Gerlach, Karen E.
    Leung, Jessica W. T.
    [J]. AMERICAN JOURNAL OF PREVENTIVE MEDICINE, 2020, 58 (03) : 470 - 472
  • [9] Breast cancer screening using tomosynthesis in combination with digital mammography compared to digital mammography alone: a cohort study within the PROSPR consortium
    Conant, Emily F.
    Beaber, Elisabeth F.
    Sprague, Brian L.
    Herschorn, Sally D.
    Weaver, Donald L.
    Onega, Tracy
    Tosteson, Anna N. A.
    McCarthy, Anne Marie
    Poplack, Steven P.
    Haas, Jennifer S.
    Armstrong, Katrina
    Schnall, Mitchell D.
    Barlow, William E.
    [J]. BREAST CANCER RESEARCH AND TREATMENT, 2016, 156 (01) : 109 - 116
  • [10] Breast cancer screening using tomosynthesis in combination with digital mammography compared to digital mammography alone: a cohort study within the PROSPR consortium
    Emily F. Conant
    Elisabeth F. Beaber
    Brian L. Sprague
    Sally D. Herschorn
    Donald L. Weaver
    Tracy Onega
    Anna N. A. Tosteson
    Anne Marie McCarthy
    Steven P. Poplack
    Jennifer S. Haas
    Katrina Armstrong
    Mitchell D. Schnall
    William E. Barlow
    [J]. Breast Cancer Research and Treatment, 2016, 156 : 109 - 116