Breast Cancer Screening Using Tomosynthesis in Combination With Digital Mammography

被引:619
|
作者
Friedewald, Sarah M. [1 ]
Rafferty, Elizabeth A. [2 ]
Rose, Stephen L. [3 ,4 ]
Durand, Melissa A. [5 ]
Plecha, Donna M. [6 ]
Greenberg, Julianne S. [7 ]
Hayes, Mary K. [8 ,9 ]
Copit, Debra S. [10 ]
Carlson, Kara L. [11 ,12 ]
Cink, Thomas M. [13 ]
Barke, Lora D. [14 ,15 ]
Greer, Linda N. [16 ]
Miller, Dave P. [17 ]
Conant, Emily F. [18 ]
机构
[1] Advocate Lutheran Gen Hosp, Ctr Adv Care, Caldwell Breast Ctr, Park Ridge, IL 60068 USA
[2] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[3] TOPS Comprehens Breast Ctr, Houston, TX USA
[4] Solis Womens Hlth, Dallas, TX USA
[5] Yale Univ, Sch Med, Dept Diagnost Radiol, Breast Imaging Sect, New Haven, CT 06510 USA
[6] Univ Hosp Case Med Ctr, Dept Radiol, Cleveland, OH USA
[7] Washington Radiol Associates, Fairfax, VA USA
[8] Radiol Associates Hollywood, Hollywood, FL USA
[9] Mem Healthcare Syst, Hollywood, FL USA
[10] Albert Einstein Healthcare Network, Dept Diagnost Radiol, Philadelphia, PA USA
[11] Evergreen Hlth Breast Ctr, Kirkland, WA USA
[12] Radia Inc, Kirkland, WA USA
[13] Edith Sanford Breast Hlth Inst, Sioux Falls, SD USA
[14] Invis Sally Jobe Breast Ctr, Denver, CO USA
[15] Radiol Imaging Associates, Denver, CO USA
[16] John C Lincoln Breast Hlth & Res Ctr, Phoenix, AZ USA
[17] ICON Clin Res, San Francisco, CA USA
[18] Univ Penn, Dept Radiol, Perelman Sch Med, Philadelphia, PA 19104 USA
来源
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION | 2014年 / 311卷 / 24期
关键词
PERFORMANCE; POPULATION; TRIAL;
D O I
10.1001/jama.2014.6095
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IMPORTANCE Mammography plays a key role in early breast cancer detection. Single-institution studies have shown that adding tomosynthesis to mammography increases cancer detection and reduces false-positive results. OBJECTIVE To determine if mammography combined with tomosynthesis is associated with better performance of breast screening programs in the United States. DESIGN, SETTING, AND PARTICIPANTS Retrospective analysis of screening performance metrics from 13 academic and nonacademic breast centers using mixed models adjusting for site as a random effect. EXPOSURES Period 1: digital mammography screening examinations 1 year before tomosynthesis implementation (start dates ranged from March 2010 to October 2011 through the date of tomosynthesis implementation); period 2: digital mammography plus tomosynthesis examinations from initiation of tomosynthesis screening (March 2011 to October 2012) through December 31, 2012. MAIN OUTCOMES AND MEASURES Recall rate for additional imaging, cancer detection rate, and positive predictive values for recall and for biopsy. RESULTS A total of 454 850 examinations (n = 281 187 digital mammography; n = 173 663 digital mammography + tomosynthesis) were evaluated. With digital mammography, 29 726 patients were recalled and 5056 biopsies resulted in cancer diagnosis in 1207 patients (n = 815 invasive; n = 392 in situ). With digital mammography + tomosynthesis, 15 541 patients were recalled and 3285 biopsies resulted in cancer diagnosis in 950 patients (n = 707 invasive; n = 243 in situ). Model-adjusted rates per 1000 screens were as follows: for recall rate, 107 (95% CI, 89-124) with digital mammography vs 91 (95% CI, 73-108) with digital mammography + tomosynthesis; difference, -16 (95% CI, -18 to -14; P < .001); for biopsies, 18.1 (95% CI, 15.4-20.8) with digital mammography vs 19.3 (95% CI, 16.6-22.1) with digital mammography + tomosynthesis; difference, 1.3 (95% CI, 0.4-2.1; P = .004); for cancer detection, 4.2 (95% CI, 3.8-4.7) with digital mammography vs 5.4 (95% CI, 4.9-6.0) with digital mammography + tomosynthesis; difference, 1.2 (95% CI, 0.8-1.6; P < .001); and for invasive cancer detection, 2.9 (95% CI, 2.5-3.2) with digital mammography vs 4.1 (95% CI, 3.7-4.5) with digital mammography + tomosynthesis; difference, 1.2 (95% CI, 0.8-1.6; P < .001). The in situ cancer detection rate was 1.4 (95% CI, 1.2-1.6) per 1000 screens with both methods. Adding tomosynthesis was associated with an increase in the positive predictive value for recall from 4.3% to 6.4%(difference, 2.1%; 95% CI, 1.7%-2.5%; P < .001) and for biopsy from 24.2% to 29.2%(difference, 5.0%; 95% CI, 3.0%-7.0%; P < .001). CONCLUSIONS AND RELEVANCE Addition of tomosynthesis to digital mammography was associated with a decrease in recall rate and an increase in cancer detection rate. Further studies are needed to assess the relationship to clinical outcomes.
引用
收藏
页码:2499 / 2507
页数:9
相关论文
共 50 条
  • [31] Microcalcifications Detected at Screening Mammography: Synthetic Mammography and Digital Breast Tomosynthesis versus Digital Mammography
    Lai, Yi-Chen
    Ray, Kimberly M.
    Lee, Amie Y.
    Hayward, Jessica H.
    Freimanis, Rita I.
    Lobach, Iryna V.
    Joe, Bonnie N.
    RADIOLOGY, 2018, 289 (03) : 630 - 638
  • [32] Breast Cancer Detection: Digital Breast Tomosynthesis with Synthesized Mammography versus Digital Mammography
    Ha, Su Min
    Chang, Jung Min
    RADIOLOGY, 2023, 309 (03)
  • [33] Impact of switching from digital mammography to tomosynthesis plus digital mammography on breast cancer screening in Alberta, Canada
    Pang, Jack X. Q.
    Newsome, James
    Sun, Maggie
    Chiang, Bonnie
    Mutti-Packer, Seema
    McDonald, Sheila W.
    Yang, Huiming
    JOURNAL OF MEDICAL SCREENING, 2022, 29 (01) : 38 - 43
  • [34] Breast cancer screening in women with and without implants: retrospective study comparing digital mammography to digital mammography combined with digital breast tomosynthesis
    Ethan O. Cohen
    Rachel E. Perry
    Hilda H. Tso
    Kanchan A. Phalak
    Michele D. Lesslie
    Karen E. Gerlach
    Jia Sun
    Ashmitha Srinivasan
    Jessica W. T. Leung
    European Radiology, 2021, 31 : 9499 - 9510
  • [35] Breast cancer screening in women with and without implants: retrospective study comparing digital mammography to digital mammography combined with digital breast tomosynthesis
    Cohen, Ethan O.
    Perry, Rachel E.
    Tso, Hilda H.
    Phalak, Kanchan A.
    Lesslie, Michele D.
    Gerlach, Karen E.
    Sun, Jia
    Srinivasan, Ashmitha
    Leung, Jessica W. T.
    EUROPEAN RADIOLOGY, 2021, 31 (12) : 9499 - 9510
  • [36] Performance of Digital Breast Tomosynthesis, Synthetic Mammography, and Digital Mammography in Breast Cancer Screening: A Systematic Review and Meta-Analysis
    Alabousi, Mostafa
    Wadera, Akshay
    Al-Ghita, Mohammed Kashif
    Al-Ghetaa, Rayeh Kashef
    Salameh, Jean-Paul
    Pozdnyakov, Alex
    Zha, Nanxi
    Samoilov, Lucy
    Sharifabadi, Anahita Dehmoobad
    Sadeghirad, Behnam
    Freitas, Vivianne
    McInnes, Matthew D. F.
    Alabousi, Abdullah
    JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2021, 113 (06): : 680 - 690
  • [37] Community-Based Breast Cancer Screening Using Digital Breast Tomosynthesis Versus Digital Mammography: Comparison of Screening Performance and Tumor Characteristics
    Regen-Tuero, Helaina C.
    Ram, Shruthi
    Gass, Jennifer S.
    Lourenco, Ana P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (02) : 249 - 256
  • [38] Digital Mammography and Digital Breast Tomosynthesis
    Moseley, Tanya W.
    CLINICAL OBSTETRICS AND GYNECOLOGY, 2016, 59 (02): : 362 - 379
  • [39] Synthesized Mammography: The New Standard of Care When Screening for Breast Cancer with Digital Breast Tomosynthesis?
    Ambinder, Emily B.
    Harvey, Susan C.
    Panigrahi, Babita
    Li, Ximin
    Woods, Ryan W.
    ACADEMIC RADIOLOGY, 2018, 25 (08) : 973 - 976
  • [40] Breast cancer screening with digital breast tomosynthesis
    Skaane, Per
    BREAST CANCER, 2017, 24 (01) : 32 - 41