The Effect of Telemonitoring (TM) on Improving Adherence with Continuous Positive Airway Pressure (CPAP) in Obstructive Sleep Apnoea (OSA): A Service Improvement Project (SIP)

被引:2
|
作者
Gassama, Abubacarr [1 ]
Mukherjee, Deyashini [2 ,3 ]
Ahmed, Urwah [1 ]
Coelho, Shirley [1 ]
Daniels, Mindi [1 ]
Mukherjee, Rahul [1 ,4 ]
机构
[1] Univ Hosp Birmingham NHS Fdn Trust, Birmingham B9 5SS, W Midlands, England
[2] Univ Hosp Coventry, Coventry CV2 2DX, W Midlands, England
[3] Univ Hosp Warwickshire, Coventry CV2 2DX, W Midlands, England
[4] Univ Birmingham, Inst Clin Sci, Birmingham B15 2TT, W Midlands, England
关键词
OSA; CPAP; telemonitoring; adherence; HYPERTENSION; MECHANISMS; DISEASE;
D O I
10.3390/healthcare10030465
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
The benefits of CPAP demonstrated in clinical trials are difficult to deliver in real life due to the lack of adherence. We analysed the effect of a Telemonitoring (TM)-related intervention on adherence as part of a Service Improvement Project (SIP) analysed as a retrospective cohort study. The 'historical control' (HC) cohort (followed up in conventional clinics) included all patients who commenced on CPAP between 1 February and 30 April 2019 (n = 142). The 'telemonitoring' (TM) cohort included all patients who commenced on CPAP between 1 May and 31 July 2019 (n = 166). Adherence was checked at 30 days (baseline) and 73 days for both cohorts. Wilcoxon-Rank test was used for statistical analysis (results reported as mean +/- SEM). Both cohorts had similar adherence at the 30-day baseline, compared to a significantly lower adherence in the HC-cohort at 73 days (55.7 +/- 3.0 vs. 51.8 +/- 3.2% of days >= 4 h: p = 0.0072, average usage 255 +/- 12.8 vs. 236 +/- 13.7 min: p = 0.0003). There was a significantly higher adherence in the TM-cohort at 73 days (50.8 +/- 2.5 vs. 56.1 +/- 2.9% of days >= 4 h: p = 0.0075; average usage 234 +/- 10.4 vs. 252 +/- 12.1 min: p = 0.0456). Telemonitoring-feedback is effective at improving adherence with CPAP, suggesting its potential beneficial role in the community setting, particularly in the post-COVID reality of increased remote consultations.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] The effect of positive and negative message framing on continuous positive airway pressure (CPAP) therapy adherence in patients eth obstructive sleep apnoea
    Berry, Marc
    Czaban, Marcin
    Pengo, Martino
    Nirmalan, Prajeshan
    Steier, Joerg
    EUROPEAN RESPIRATORY JOURNAL, 2014, 44
  • [22] Impact of continuous positive airway pressure (CPAP) on chronic cough in obstructive sleep apnoea (OSA) - a randomized controlled trial
    Chan, K.
    Birring, S.
    Cossa, G.
    Laks, L.
    Rogers, P.
    Ing, A.
    JOURNAL OF SLEEP RESEARCH, 2014, 23 : 153 - 153
  • [23] IMPACT OF CONTINUOUS POSITIVE AIRWAY PRESSURE (CPAP) ON CHRONIC COUGH IN OBSTRUCTIVE SLEEP APNOEA (OSA) - A RANDOMIZED CONTROLLED TRIAL
    Chan, K.
    Cossa, G.
    Laks, L.
    Birring, S.
    Ing, A.
    RESPIROLOGY, 2014, 19 : 51 - 51
  • [24] ADHERENCE TO CONTINUOUS POSITIVE AIRWAY PRESSURE (CPAP) TREATMENT IN PATIENTS WITH OBSTRUCTIVE SLEEP APNEA (OSA) THROUGH TELEMONITORING: EXPERIENCE IN A REFERENCE HOSPITAL IN NORTHEASTERN BRAZIL
    Moreira Cardoso, M. E.
    Mendonca do Nascimento, M. E.
    Coelho de Possidio, L. J.
    Silva Climaco, D. C.
    Goncalves Martinez, S. C.
    Neves Santos Silva, T.
    SLEEP MEDICINE, 2024, 115 : 318 - 318
  • [25] Prevalence of cognitive impairment and the effect of continuous positive airway pressure (CPAP) towards cognition among patients with obstructive sleep apnoea (OSA)
    Fauad, Muhammad Farid Mohd
    Ismail, Ahmad Izuanuddin
    Bhaskar, Shalini
    Tarmizi, Noor Azleen Ahmad
    RESPIROLOGY, 2023, 28 : 117 - 117
  • [26] The effect of continuous positive airway pressure (CPAP) on energy expenditure in obstructive sleep apnoea - preliminary findings
    O'Driscoll, D.
    Turton, A.
    Copland, J.
    Ong, C.
    Strauss, B.
    Hamilton, G.
    JOURNAL OF SLEEP RESEARCH, 2011, 20 : 47 - 48
  • [27] Machine learning-based prediction of adherence to continuous positive airway pressure (CPAP) in obstructive sleep apnea (OSA)
    Scioscia, Giulia
    Tondo, Pasquale
    Barbaro, Maria Pia Foschino
    Sabato, Roberto
    Gallo, Crescenzio
    Maci, Federica
    Lacedonia, Donato
    INFORMATICS FOR HEALTH & SOCIAL CARE, 2022, 47 (03): : 274 - 282
  • [28] INCREASED VENTILATION IN RESPONSE TO MILD HYPOXIA IN PATIENTS WITH OBSTRUCTIVE SLEEP APNOEA (OSA) IS NOT REVERSED BY CONTINUOUS POSITIVE AIRWAY PRESSURE (CPAP)
    Meggitt, E.
    Seccombe, L.
    Cossa, G.
    Rogers, P.
    Laks, L.
    Peters, M.
    RESPIROLOGY, 2012, 17 : 80 - 80
  • [29] Outcomes in patients with REM related obstructive sleep apnoea (REM-OSA) treated with continuous positive airway pressure (CPAP)
    Hu, Xiao Ya
    Perri, Rita
    Ting, Terence
    Al Oweidat, Khaled
    Lambert, Stephen
    Wheatley, John
    EUROPEAN RESPIRATORY JOURNAL, 2019, 54
  • [30] DO OBSTRUCTIVE SLEEP APNOEA (OSA) PATIENTS WITH NORMAL EPWORTH SCORES COMPLY WITH CONTINUOUS POSITIVE AIRWAY PRESSURE (CPAP) THERAPY?
    Pagonda, R.
    Thangakunam, B.
    Mabuto, C.
    Basharet, I.
    Yung, B.
    Mukherjee, D.
    Wadsworth, K.
    Samuel, J.
    THORAX, 2011, 66 : A76 - A76