Clay delamination in clay/poly(dicyclopentadiene) nanocomposites quantified by small angle neutron scattering and high-resolution transmission electron microscopy

被引:63
|
作者
Yoonessi, M
Toghiani, H
Daulton, TL
Lin, JS
Pittman, CU [1 ]
机构
[1] Mississippi State Univ, Dept Chem, Mississippi State, MS 39762 USA
[2] Mississippi State Univ, Dave C Swalm Sch Chem Engn, Mississippi State, MS 39762 USA
[3] Oak Ridge Natl Lab, Oak Ridge, TN 37831 USA
[4] USN, Res Lab, Marine Geosci Div, Stennis Space Ctr, Stennis Space Ctr, MS 39529 USA
关键词
D O I
10.1021/ma048663e
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Highly delaminated clay/poly(dicyclopentadiene) nanocomposites were prepared by in-situ, ring-opening metathesis polymerization of presonicated mixtures of the liquid dicyclopentadiene (DCPD) and organically modified Montmorillonite clays. Three nanocomposite series (using Montmorillonites: I-28,I-44pa) of increasing clay loadings (0.5, 1.0, and 2.0 wt%) and modified Montmorillonite PGW (0.5 wt%) were synthesized. The dispersed microstructure of the clays in the nanocomposites was characterized by small-angle neutron scattering (SANS), ultra-small-angle neutron scattering (USANS), small-angle X-ray scattering (SAXS), and high-resolution transmission electron microscopy (HR-TEM). All clays were highly delaminated and well dispersed within their host matrixes. The mean number of individual clay platelets per tactoid was predicted by fitting SANS data to the stacked-disk model and measured directly from HR-TEM images of a large number of tactoids in each sample. SANS results were in good agreement with HR-TEM for composites with low clay concentrations (0.5 wt%); however, deviations were observed at higher clay loadings (2.0 wt%). These deviations are discussed in terms of several factors not taken into account by the stacked-disk model: (a) long-range interactions, which become more important at high loadings; (b) departure of tactoid geometries from parallel stacks of rigid disks; and (c) the polydispersity of tactoid thicknesses. SAXS peaks were not present for most of the synthesized nanocomposites, suggesting a high degree of clay delamination was achieved. However, a broad peak was observed for the 2.0 wt% I-44pa clay nanocomposite, indicating the presence of some larger tactoids than in the other nanocomposites having a range of d-spacings. The HR-TEM measured distributions of clay platelet d-spacings in tactoids dispersed within the nanocomposites which were in the range from 8 to 20 Angstrom (12-15 Angstrom average), indicating that the quaternary ammonium ion pillaring agents were no longer present. These quaternary salts either decomposed during the high-temperature (260 degreesC) stage of curing or were not fully exchanged with the interlayer cations present between all platelet interlayers during the original clay modification. Clay/polyDCPD composites were also prepared using PGW clay modified by poly(ethylene glycol). This clay dispersed more rapidly, needing less sonication than the other clays. The resistance to delamination of all nanocomposites studied increased with greater clay loading under equivalent synthesis conditions.
引用
收藏
页码:818 / 831
页数:14
相关论文
共 50 条
  • [31] HIGH-RESOLUTION TRANSMISSION ELECTRON-MICROSCOPY (HRTEM)
    GRUEHN, R
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 333 (07): : 781 - 781
  • [32] High-resolution analysis system for transmission electron microscopy
    Tarazona, V
    BIOFUTUR, 1997, (169) : A6 - A8
  • [33] An Introduction to High-resolution EELS in Transmission Electron Microscopy
    Grogger, Werner
    Hofer, Ferdinand
    Kothleitner, Gerald
    Schaffer, Bernhard
    TOPICS IN CATALYSIS, 2008, 50 (1-4) : 200 - 207
  • [34] Advances in high-resolution transmission electron microscopy for catalysis
    Helveg, Stig
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 240
  • [35] High-resolution transmission electron microscopy on aged InPHBTs
    Perham, TJ
    Paine, BM
    Thomas, S
    2003 GAAS RELIABILITY WORKSHOP, PROCEEDINGS, 2003, : 83 - 105
  • [36] High-resolution transmission electron microscopy of polymer crystals
    Tosaka, M
    Tsuji, M
    Kohjiya, S
    MATERIALS SCIENCE RESEARCH INTERNATIONAL, 1998, 4 (02): : 79 - 85
  • [37] Interpretability of high-resolution transmission electron microscopy images
    Lomholdt, William Bang
    Larsen, Matthew Helmi Leth
    Valencia, Cuauhtemoc Nunez
    Schiotz, Jakob
    Hansen, Thomas Willum
    ULTRAMICROSCOPY, 2024, 263
  • [38] High-resolution transmission electron microscopy on aged InPHBTs
    Paine, BM
    Perham, TJ
    Thomas, S
    MICROELECTRONICS RELIABILITY, 2004, 44 (07) : 1055 - 1060
  • [39] Present developments in high-resolution transmission electron microscopy
    Ernst, F
    Ruhle, M
    CURRENT OPINION IN SOLID STATE & MATERIALS SCIENCE, 1997, 2 (04): : 469 - 476
  • [40] HIGH-RESOLUTION TRANSMISSION ELECTRON-MICROSCOPY IN MINERALOGY
    BUSECK, PR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 196 : 119 - GEOC