Dynamic Characteristics Monitoring Changes of Damaged and Retrofitted RC Buildings

被引:2
|
作者
Gunaydin, M. [1 ]
Adanur, S. [1 ]
Altunisik, A. C. [1 ]
Mosallam, A. [2 ]
Sevim, B. [3 ]
机构
[1] Karadeniz Tech Univ, Dept Civil Engn, TR-61080 Trabzon, Turkey
[2] Univ Calif Irvine, Dept Civil & Environm Engn, Irvine, CA 92697 USA
[3] Yildiz Tech Univ, Dept Civil Engn, Istanbul, Turkey
关键词
Ambient vibration test; Carbon fiber reinforced polymer; Dynamic characteristics; Epoxy injection method; High-strength structural mortar; Stochastic subspace identification method; SEISMIC PERFORMANCE; FRAME; BEAMS; IDENTIFICATION; BEHAVIOR; JOINTS; REHABILITATION; DUCTILITY; STRENGTH; SLABS;
D O I
10.1007/s40799-021-00493-x
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper presents results of an experimental study that focuses on monitoring changes in dynamic characteristics of a damaged and retrofitted two-story reinforced concrete (RC) building model with poor detailing. In the study, ambient vibration tests are performed via four test setup protocols in order to monitor changes in dynamic characteristics before and after such setups. The four main test setups are: (i) undamaged (as-built) case (Setup # 1), (ii) damaged cases with different degrees of damages (Setup # 2), (iii) repaired case with different types of repair methods (Setup # 3), and (iv) strengthened case with externally bonded CFRP composite laminates (Setup # 4). In addition, a total of eight ambient vibration tests are conducted in order to assess the effects of degree of damage and associated retrofit systems on building's dynamic characteristics such as natural frequencies, mode shapes, and damping ratios. The Stochastic Subspace Identification (SSI) Method is used to identify the dynamic characteristics. Experimentally identified dynamic characteristics obtained from all setups are compared with each other in order to detect the effect of damage and repair applications on the structure's dynamic characteristics. Moreover, Modal Assurance Criterion (MAC) and Coordinate Modal Assurance Criterion (COMAC) are determined to examine the changes of stiffness of each RC building model.
引用
下载
收藏
页码:457 / 484
页数:28
相关论文
共 50 条
  • [11] SEISMIC BEHAVIORS OF BFRP-RETROFITTED EARTHQUAKE-DAMAGED RC COLUMNS
    Ma, Gao
    Li, Hui
    PROCEEDINGS OF THE THIRTEENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOLS 1 AND II, 2014, : 1488 - 1493
  • [12] ECOCENTRE Project: Monitoring energy in retrofitted buildings.
    Cocchi, S
    Conti, F
    REBUILD - THE EUROPEAN CITIES OF TOMORROW: SHAPING OUR EUROPEAN CITIES FOR THE 21ST CENTURY, 1998, : 35 - 38
  • [13] MONITORING THE DYNAMIC CHARACTERISTICS OF TALL BUILDINGS BY GPS TECHNIQUE
    LUO Zhicai CHEN Yongqi LIU Yanxiong
    Geo-spatial Information Science, 2000, (04) : 61 - 66
  • [14] Axial compression testing of an emergency-retrofitted shear-damaged RC column
    Nakada, K.
    Kochi, M.
    Arakaki, S.
    Karwand, H.
    Noori, M. Z.
    CONCRETE REPAIR, REHABILITATION AND RETROFITTING IV, 2016, : 130 - 131
  • [15] Stability Assessment of a Fire-damaged Retrofitted RC Structure Having Vertical Irregularity
    Mazharuddin, Mohammed
    Guruprasad, Y.K.
    Lecture Notes in Civil Engineering, 2022, 202 : 349 - 363
  • [16] Seismic Performance of Masonry Buildings Retrofitted by Pre-Cast RC Panels
    Wang, Tao
    Chen, Xi
    Li, Wenfeng
    Miao, Qisong
    PROGRESS IN STRUCTURE, PTS 1-4, 2012, 166-169 : 1811 - +
  • [17] Pseudo Dynamic Testing of an RC Frame Retrofitted with Chevron Braces
    Ozcelik, R.
    Binici, B.
    Kurc, O.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2012, 16 (04) : 515 - 539
  • [18] Modeling the Seismic Response of Modern URM Buildings Retrofitted by Adding RC Walls
    Paparo, Alessandro
    Beyer, Katrin
    JOURNAL OF EARTHQUAKE ENGINEERING, 2016, 20 (04) : 587 - 610
  • [19] Dynamic behaviour and modelling of RC beams retrofitted with CFRP sheets
    Bonfiglioli, B
    Pascale, G
    PROBLEMS IN STRUCTURAL IDENTIFICATION AND DIAGNOSTICS: GENERAL ASPECTS AND APPLICATIONS, 2003, (471): : 47 - 57
  • [20] Changes in dynamic characteristics of Lorca RC buildings from pre- and post-earthquake ambient vibration data
    F. Vidal
    M. Navarro
    C. Aranda
    T. Enomoto
    Bulletin of Earthquake Engineering, 2014, 12 : 2095 - 2110