Development and validation of LC-MS/MS methods to measure tobramycin and lincomycin in plasma, microdialysis fluid and urine: application to a pilot pharmacokinetic research study

被引:8
|
作者
Pandey, Saurabh [1 ]
Dhanani, Jayesh [1 ,2 ]
Lipman, Jeffrey [1 ,2 ]
Roberts, Jason A. [1 ,2 ,3 ,4 ]
Wallis, Steve C. [1 ]
Parker, Suzanne L. [1 ]
机构
[1] Univ Queensland, Fac Med, UQ Ctr Clin Res, Brisbane, Qld, Australia
[2] Royal Brisbane & Womens Hosp, Dept Intens Care Med, Brisbane, Qld, Australia
[3] Royal Brisbane & Womens Hosp, Dept Pharm, Brisbane, Qld, Australia
[4] Univ Queensland, Ctr Translat Antiinfect Pharmacodynam, Sch Pharm, Brisbane, Qld, Australia
关键词
lincomycin; mass spectrometry; microdialysis; plasma; tobramycin; urine; TANDEM-MASS-SPECTROMETRY; CHROMATOGRAPHY; QUANTIFICATION; RESIDUES; ANTIBIOTICS;
D O I
10.1515/cclm-2019-0780
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The aim of our work was to develop and validate a hydrophilic interaction liquid chromatography- electrospray ionization-tandem mass spectrometry (HILIC-ESI-MS/MS) methods for the quantification of tobramycin (TMC) and lincomycin (LMC)in plasma, microdialysis fluid and urine. Methods: Protein precipitation was used to extract TMC and LMC from plasma, while microdialysis fluid and urine sample were diluted prior to instrumental analysis. Mobile phase A consisted of 2 mM ammonium acetate in 10% acetonitrile with 0.2% formic acid (v/v) and mobile phase B consisted of 2 mM ammonium acetate in 90% acetonitrile with 0.2% formic acid (v/v). Gradient separation (80%-10% of mobile phase B) for TMC was done using a SeQuant zic-HILIC analytical guard column. While separation of LMC was performed using gradient elution (100%-40% of mobile phase B) on a SeQuant zic-HILIC analytical column equipped with a SeQuant zic-HILIC guard column. Vancomycin (VCM) was used as an internal standard. A quadratic calibration was obtained over the concentration range for plasma of 0.1-20 mg/L for TMC and 0.05-20 mg/L for LMC, for microdialysis fluid of -0.1-20 mg/L for both TMC and LMC, and 1-100 mg/L for urine for both TMC and LMC. Results: For TMS and LMC, validation testing for matrix effects, precision and accuracy, specificity and stability were all within acceptance criteria of +/- 15%. Conclusions: The methods described here meet validation acceptance criteria and were suitable for application in a pilot pharmacokinetic research study performed in a sheep model.
引用
收藏
页码:274 / 284
页数:11
相关论文
共 50 条
  • [41] Development and validation of a sensitive LC-MS/MS method with electrospray ionization for quantitation of rhein in human plasma: application to a pharmacokinetic study
    Layek, Buddhadev
    Kumar, T. Santosh
    Trivedi, Ravi Kumar
    Mullangi, Ramesh
    Srinivas, Nuggehally R.
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (06) : 616 - 624
  • [42] Development and Validation of a Rapid and Simple LC-MS/MS Method for Quantification of Vemurafenib in Human Plasma: Application to a Human Pharmacokinetic Study
    Bihan, Kevin
    Sauzay, Chloe
    Goldwirt, Lauriane
    Charbonnier-Beaupel, Fanny
    Hulot, Jean-Sebastien
    Funck-Brentano, Christian
    Zahr, Noel
    THERAPEUTIC DRUG MONITORING, 2015, 37 (01) : 132 - 136
  • [43] Development and validation of a highly sensitive LC-MS/MS assay for determination of rifampicin in human plasma: application to clinical pharmacokinetic study
    Srivastava, A.
    Ward, S.
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2012, 73 (06) : 998 - 999
  • [44] Development and validation of an LC-MS/MS method for simultaneous quantification of eight drugs in plasma and brain: Application in a pharmacokinetic study in mice
    Lentzas, Aristeidis
    Venekamp, Nikkie
    Beijnen, Jos H.
    van Tellingen, Olaf
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2024, 1247
  • [45] Development and Validation of an LC-MS/MS Method for Determination of Tigecycline and Its Epimer in Human Plasma and Its Application in a Pharmacokinetic Study
    Wang, Longyuan
    Hu, Xiaoxiao
    Zhu, Hong
    Zhang, Xiaotian
    Wang, Chuan
    Han, Zhiwu
    ACTA CHROMATOGRAPHICA, 2016, 28 (02) : 239 - 253
  • [46] Development and validation of a sensitive LC-MS/MS-ESI method for the determination of ivabradine in human plasma: application to a pharmacokinetic study
    Jiang, Juanjuan
    Tian, Lei
    Huang, Yiling
    Li, Yishi
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (12) : 1603 - 1608
  • [47] Development and validation of a LC-MS/MS method for quantitation of recombinant human growth hormone in rat plasma and application to a pharmacokinetic study
    Huang, Wen-si
    Yu, Jing-hua
    Diao, Xing-xing
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 224
  • [48] Development and validation of an LC-MS/MS method for the simultaneous quantification of milbemycin oxime and praziquantel in plasma: application to a pharmacokinetic study in cats
    Xie, Shiting
    Lu, Yixing
    Wang, Jun
    Lin, Changcheng
    Ye, Peiyu
    Liu, Xiaolin
    Xiong, Wenguang
    Zeng, Zhenling
    Zeng, Dongping
    FRONTIERS IN VETERINARY SCIENCE, 2023, 10
  • [49] The development and validation of sensitive LC-MS/MS method for quantitative bioanalysis of carmofur in mouse plasma and its application to pharmacokinetic study
    Islam, Mohammad Mohiminul
    Kub, Ethan F.
    Rajaratnam, Vilashini
    Mirza, Shama P.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1212
  • [50] Development and validation of a highly sensitive LC-MS/MS method for quantitation of dexlansoprazole in human plasma: application to a human pharmacokinetic study
    Hotha, Kishore Kumar
    Bharathi, D. Vijaya
    Jagadeesh, B.
    Ravindranath, L. K.
    Veera, K. N. Jaya
    Venkateswarulu, V.
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (02) : 192 - 198