Model assessment for the prediction of mass transfer coefficients in liquid-liquid extraction columns

被引:9
|
作者
Outili, N.
Meniai, A.-H. [1 ]
Gneist, G.
Bart, H.-J.
机构
[1] Univ Mentouri, Lab Ingn Procedes Environm, Constantine 25000, Algeria
[2] Tech Univ, Dept Proc Engn, Kaiserslautern, Germany
关键词
drops; dispersed systems; extraction; mass transfer;
D O I
10.1002/ceat.200600356
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A large number of theories are reported in the literature for the calculation of individual mass transfer coefficients and each has a well defined application range, which depends on the nature of the continuous and the dispersed phases. Each theory is also based on a different transfer mode, e.g., the dispersed phase depends essentially on the drop behavior, which is directly related to the drop size. However, an accurate determination of the overall mass transfer coefficient depends upon the choice of the combination of theories to be used for the calculation of the individual mass transfer coefficients, i.e., for the continuous and dispersed phases. In the present work, different combinations for the calculation of the overall mass transfer coefficient have been tested for the commonly recommended Acetone/Toluene/Water system, which is characterized by relatively large drop sizes.
引用
收藏
页码:758 / 763
页数:6
相关论文
共 50 条
  • [31] MASS AND HEAT TRANSFER FROM DROPS IN LIQUID-LIQUID EXTRACTION
    HANDLOS, AE
    BARON, T
    AICHE JOURNAL, 1957, 3 (01) : 127 - 136
  • [32] Mass transfer coefficient in the eductor liquid-liquid extraction column
    Bahare Esmaeeli
    Ahad Ghaemi
    Mansour Shirvani
    Mostafa Hosseinzadeh
    Chinese Journal of Chemical Engineering, 2021, 40 (12) : 27 - 35
  • [33] Mass transfer coefficient in the eductor liquid-liquid extraction column
    Esmaeeli, Bahare
    Ghaemi, Ahad
    Shirvani, Mansour
    Hosseinzadeh, Mostafa
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2021, 40 : 27 - 35
  • [34] Limiting flow in liquid-liquid extraction columns
    Blanding, FH
    Elgin, JC
    TRANSACTIONS OF THE AMERICAN INSTITUTE OF CHEMICAL ENGINEERS, 1942, 38 (02): : 0305 - 0338
  • [36] Prediction of pressure drop in liquid-liquid pulsed packed extraction countercurrent columns
    Khooshechin, Sajad
    Safdari, Jaber
    Moosavian, Mohammad Ali
    Mallah, Mohammad Hassan
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2013, 44 : 684 - 691
  • [37] LIQUID-LIQUID EXTRACTION SPRAY COLUMNS - DROP FORMATION AND INTERFACIAL TRANSFER AREA
    KEITH, FW
    HIXSON, AN
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1955, 47 (02): : 258 - 267
  • [38] Mass Transfer Enhancement in Liquid-Liquid Extraction with Discrete Liquid Film Flow
    Chang, Chao
    Zheng, Qijun
    Wang, Yong
    Su, Zhenning
    Wang, Baoqun
    Kuang, Shibo
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2023, 62 (42) : 17297 - 17305
  • [39] A General Correlation For The Dispersed Phase Mass Transfer Coefficient For Single Drop Systems In Liquid-Liquid Extraction Columns
    Outili, N., I
    Meniai, A-H
    Guido, G.
    Bart, J-H
    ICHEAP-9: 9TH INTERNATIONAL CONFERENCE ON CHEMICAL AND PROCESS ENGINEERING, PTS 1-3, 2009, 17 : 615 - 620
  • [40] Numerical solution of the bivariate population balance equation for the interacting hydrodynamics and mass transfer in liquid-liquid extraction columns
    Attarakih, MM
    Bart, HJ
    Faqir, NM
    CHEMICAL ENGINEERING SCIENCE, 2006, 61 (01) : 113 - 123