QRS/T angle;
standard leads;
ECG methods;
risk prediction;
D O I:
10.1016/j.jelectrocard.2006.11.003
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
yThe spatial QRS/T angle has been identified as a strong predictor of adverse cardiac events. Mean QRS and T amplitudes from X, Y, and Z leads generated by a matrix transformation method are often used to calculate the QRS/T angle (QRS/T-matrix). Many investigators find this procedure cumbersome. We used electrocardiographic data files of 14881 men and women aged 45 to 65 years from the Atherosclerosis in Communities study to derive a simple formula for estimated spatial QRS/T angle (QRS/T-simple). QRS/T-simple is calculated as the inverse cosine between the mean QRS and T vectors, which are approximated by 3 QRS(net) and T-net amplitudes for each vector. QRS/T-simple explained 79% of the variance of QRS/T-matrix (r = 0.89). Using sex-specific thresholds, QRS/T-simple detected abnormally wide QRS/T-matrix values with a sensitivity of 91% and specificity of 88%. It is concluded that this simple method may provide a satisfactory substitute for QRS/T from the matrix transformation method. (C) 2007 Elsevier Inc. All rights reserved.