摘要
Introduction: The modern scleral contact lens (ScCL) has evolved from the very first contact lens fitted 128 years ago. Originally manufactured in glass and oxygen impermeable plastics, these lenses are available today in high Dk gas permeable materials that allow permeation of oxygen, reducing many of the complications that were seen with older generation ScCL. However, as with any new contact lens modality, the modern ScCL brings with it a new set of complications and fitting limitations. Methods: Pubmed searches under different keywords were conducted. Results: Existing literature provides some reports of infection with the scleral devices, although these are often seen in severely compromised corneas, while hypoxic and inflammatory complications are rarely reported in the literature. Furthermore, the somewhat complex relationship of a scleral lens on the eye can create fitting and removal challenges. Anomalies such as conjunctival prolapse, epithelial bogging, midday fogging, and limbal bearing have been reported, and appear to be unique sequelae to scleral lens wear. Conclusion: Although this revolutionary technology broadens the scope in which practitioners can treat patients with irregular ocular surfaces, reports of these complications indicate that there is still a need for continued research to further enhance the clinical outcomes of this promising contact lens modality. Published by Elsevier Ltd on behalf of British Contact Lens Association.
引用
收藏
页码:88 / 96
页数:9
相关论文
共 50 条
  • [31] Scleral Contact Lenses: Past and Future
    Twa, Michael D.
    [J]. OPTOMETRY AND VISION SCIENCE, 2020, 97 (09) : 655 - 657
  • [32] Aids in the fitting of contact lenses
    Eggers, H
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1939, 21 (04) : 647 - 649
  • [33] Fitting Efficiency of Impression-Based Scleral Lenses
    Nau, Amy Catherine
    Schornack, Muriel
    Harthan, Jennifer
    Nau, Cherie B.
    Fogt, Jennifer Swingle
    Shorter, Ellen
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [34] COMPLICATIONS ASSOCIATED WITH THERAPEUTIC SOFT CONTACT-LENSES
    NESBURN, AB
    [J]. OPHTHALMOLOGY, 1979, 86 (06) : 1130 - 1137
  • [35] Scleral Lenses: A Literature Review
    Schornack, Muriel M.
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2015, 41 (01): : 3 - 11
  • [36] COMPLICATIONS OF CONTACT LENSES
    不详
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 1966, 1 (5490): : 751 - +
  • [37] MEDICAL APPLICATIONS OF SCLERAL CONTACT-LENSES .2. GAS-PERMEABLE SCLERAL CONTACT-LENSES
    TAN, DTH
    PULLUM, KW
    BUCKLEY, RJ
    [J]. CORNEA, 1995, 14 (02) : 130 - 137
  • [38] Complications of Scleral-Fixated Intraocular Lenses
    Davies, Emma C.
    Pineda, Roberto, II
    [J]. SEMINARS IN OPHTHALMOLOGY, 2018, 33 (01) : 23 - 28
  • [39] Advances in scleral lenses for refractive surgery complications
    Parminder, Amy
    Jacobs, Deborah S.
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2015, 26 (04) : 243 - 248
  • [40] Evaluation of gas permeable scleral contact lenses
    Tromans, C
    Bullock, JM
    Ridgway, AEA
    Tullo, AB
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 349 - 349