摘要
Objectives/Hypothesis Previous studies have demonstrated that electrocochleography (ECochG) measurements made at the round window prior to cochlear implant (CI) electrode insertion can account for 47% of the variability in 6-month speech perception scores. Recent advances have made it possible to use the apical CI electrode to record intracochlear responses to acoustic stimuli. Study objectives were to determine 1) the relationship between intracochlear ECochG response amplitudes and 6-month speech perception scores and 2) to determine the relationship between behavioral auditory thresholds and ECochG threshold estimates. The hypothesis was that intracochlear ECochG response amplitudes made immediately after electrode insertion would be larger than historical controls (at the extracochlear site) and explain more variability in speech perception scores. Study Design Prospective case series. Methods Twenty-two adult CI recipients with varying degrees of low-frequency hearing had intracochlear ECochG measurements made immediately after CI electrode insertion using 110 dB SPL tone bursts. Tone bursts were centered at five octave-spaced frequencies between 125 and 2,000 Hz. Results There was no association between intracochlear ECochG response amplitudes and speech perception scores. But, the data suggest a mild to moderate relationship between preoperative behavioral audiometric testing and intraoperative ECochG threshold estimates. Conclusion Performing intracochlear ECochG is highly feasible and results in larger response amplitudes, but performing ECochG before, rather than after, CI insertion may provide a more accurate assessment of a patient's speech perception potential. Level of Evidence 4 Laryngoscope, 2021
引用
收藏
页码:E2681 / E2688
页数:8
相关论文
共 50 条
  • [1] Predicting Postoperative Speech Perception and Audiometric Thresholds Using Intracochlear Electrocochleography in Cochlear Implant Recipients
    Panario, Jared
    Bester, Christofer
    O'Leary, Stephen
    [J]. EAR AND HEARING, 2024, 45 (05): : 1173 - 1190
  • [2] Extra- and Intracochlear Electrocochleography in Cochlear Implant Recipients
    Dalbert, Adrian
    Pfiffner, Flurin
    Roeoesli, Christof
    Thoele, Konrad
    Sim, Jae Hoon
    Gerig, Rahel
    Huber, Alexander M.
    [J]. AUDIOLOGY AND NEURO-OTOLOGY, 2015, 20 (05) : 339 - 348
  • [3] Electrocochleography and cognition are important predictors of speech perception outcomes in noise for cochlear implant recipients
    Walia, Amit
    Shew, Matthew A.
    Kallogjeri, Dorina
    Wick, Cameron C.
    Durakovic, Nedim
    Lefler, Shannon M.
    Ortmann, Amanda J.
    Herzog, Jacques A.
    Buchman, Craig A.
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)
  • [4] Electrocochleography and cognition are important predictors of speech perception outcomes in noise for cochlear implant recipients
    Amit Walia
    Matthew A. Shew
    Dorina Kallogjeri
    Cameron C. Wick
    Nedim Durakovic
    Shannon M. Lefler
    Amanda J. Ortmann
    Jacques A. Herzog
    Craig A. Buchman
    [J]. Scientific Reports, 12
  • [5] Intraoperative Round Window Electrocochleography and Speech Perception Outcomes in Pediatric Cochlear Implant Recipients
    Formeister, Eric J.
    McClellan, Joseph H.
    Merwin, William H., III
    Iseli, Claire E.
    Calloway, Nathan H.
    Teagle, Holly F. B.
    Buchman, Craig A.
    Adunka, Oliver F.
    Fitzpatrick, Douglas C.
    [J]. EAR AND HEARING, 2015, 36 (02): : 249 - 260
  • [6] Promontory Electrocochleography Recordings to Predict Speech-Perception Performance in Cochlear Implant Recipients
    Walia, Amit
    Shew, Matthew A.
    Lee, David S.
    Lefler, Shannon M.
    Kallogjeri, Dorina
    Wick, Cameron C.
    Durakovic, Nedim
    Fitzpatrick, Douglas C.
    Ortmann, Amanda J.
    Herzog, Jacques A.
    Buchman, Craig A.
    [J]. OTOLOGY & NEUROTOLOGY, 2022, 43 (08) : 915 - 923
  • [7] Intracochlear electrocochleography findings in cochlear implant recipients with auditory neuropathy spectrum disorder
    Ulukan, Merve Bayri
    Ciprut, Ayca
    [J]. INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2023, 170
  • [8] Are Speech Perception Scores in Cochlear Implant Recipients Consistent Across Different Tests?
    Andresen, Nicholas S.
    Vohra, Varun
    Galaiya, Deepa J.
    Carver, Courtney L.
    Marsiglia, Dawn D.
    Yeagle, Jennifer D.
    Creighton, Francis X.
    Wang, Nae-Yuh
    Bowditch, Stephen P.
    Della Santina, Charles C.
    Sun, Daniel Q.
    [J]. OTOLOGY & NEUROTOLOGY, 2022, 43 (07) : E720 - E725
  • [9] Postoperative Intracochlear Electrocochleography in Pediatric Cochlear Implant Recipients: Association to Audiometric Thresholds and Auditory Performance
    Attias, Joseph
    Ulanovski, David
    Hilly, Ohad
    Greenstein, Tally
    Sokolov, Merav
    HabibAllah, Suhail
    Mormer, Hen
    Raveh, Eyal
    [J]. EAR AND HEARING, 2020, 41 (05): : 1135 - 1143
  • [10] Audiovisual speech perception in elderly cochlear implant recipients
    Hay-McCutcheon, MJ
    Pisoni, DB
    Kirk, KI
    [J]. LARYNGOSCOPE, 2005, 115 (10): : 1887 - 1894