Preliminary study of the thermal impact of a microelectrode array implanted in the brain

被引:0
|
作者
Kim, Sohee [1 ]
Normann, Richard A. [2 ]
Harrison, Reid [1 ]
Solzbacher, Florian [1 ,2 ]
机构
[1] Univ Utah, Dept Elect & Comp Engn, 50 S Cent Campus Dr, Salt Lake City, UT 84112 USA
[2] Univ Utah, Dept Bioengn, Salt Lake City, UT 84112 USA
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
One requirement of a chronically implantable, wireless neural interface device is the integration of electronic circuitry with the microelectrode array. Since the electronic IC dissipates a certain amount of power, it will affect the temperature in the tissues surrounding the implant site. In this paper, the thermal influence of an integrated, 3-dimensional Utah Electrode Array, to be implanted in the brain was investigated with simulations using the finite element method (FEM). A temperature increase in the brain tissue was predicted using preliminary simulations with simplified models. The model and method used in the simulations were verified by simple in vitro experiments.
引用
收藏
页码:5677 / +
页数:3
相关论文
共 50 条
  • [21] Microelectrode-array of IrO2 prepared by thermal treatment of pure Ir
    Fierro, Stephane
    Kapalka, Agnieszka
    Frey, Olivier
    Koudelka, Milena
    Comninellis, Christos
    ELECTROCHEMISTRY COMMUNICATIONS, 2010, 12 (04) : 587 - 591
  • [22] Astrocytic Response to Acutely- and Chronically-Implanted Microelectrode Arrays in the Marmoset (Callithrix jacchus) Brain
    Budoff, Samuel A.
    Yano, Kim M.
    de Mesquita, Fernanda C.
    Doerl, Jhulimar G.
    de Santana, Maxwell B.
    Nascimento, Manuela S. L.
    Kunicki, Ana Carolina B.
    de Araujo, Mariana E. P.
    BRAIN SCIENCES, 2019, 9 (02)
  • [23] Feasibility Study on Direct Counting of Viruses and Bacteria by Using Microelectrode Array
    Ishige, Yu
    Goto, Yusuke
    Yanagi, Itaru
    Ishida, Takeshi
    Itabashi, Naoshi
    Kamahori, Masao
    ELECTROANALYSIS, 2012, 24 (01) : 131 - 139
  • [24] ELECTRICAL STIMULATION OF THE HUMAN BRAIN THROUGH IMPLANTED ELECTRODES - PRELIMINARY OBSERVATIONS
    CHATRIAN, GE
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1960, 12 (02): : 546 - 546
  • [25] FLEXIBLE DUAL-SIDED POLYMER MICROELECTRODE ARRAY FOR NEUROPHYSIOLOGICAL RECORDINGS FROM AN INSECT BRAIN
    Liu, Xiang
    Sanchez, Simon
    Gong, Yan
    Jiang, Zebin
    Stevens, Trevor
    Banan, Hasan
    Saha, Debajit
    Li, Wen
    2024 IEEE 37TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, MEMS, 2024, : 247 - 250
  • [26] Stretchable microelectrode array: A potential tool for monitoring neuroelectrical activity during brain tissue deformation
    Yu, Zhe
    Graudejus, Oliver
    Tsay, Candice
    Lacour, Stephanie P.
    Wagner, Sigurd
    Morrison, Barclay
    JOURNAL OF NEUROTRAUMA, 2007, 24 (07) : 1278 - 1278
  • [27] Preliminary study on HA coating percutaneously implanted in bone
    Yang, BC
    Weng, J
    Li, XD
    Yang, ZJ
    Feng, JM
    Chen, JY
    Zhang, XD
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1999, 22 (10): : 713 - 718
  • [28] Microelectrode Array Probe for Simultaneous Detection of Glutamate and Local Field Potential during Brain Death
    Wei Wen-Jing
    Song Yi-Lin
    Fan Xin-Yi
    Zhang Song
    Wang Li
    Xu Sheng-Wei
    Cai Xin-Xia
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (07) : 983 - 987
  • [29] Microelectrode array stimulation combined with intrinsic optical imaging: A novel tool for functional brain mapping
    Chernov, Mykyta M.
    Chen, Gang
    Torre-Healy, Luke A.
    Friedman, Robert M.
    Roe, Anna W.
    JOURNAL OF NEUROSCIENCE METHODS, 2016, 263 : 7 - 14
  • [30] THE STUDY ON NOVEL MICROELECTRODE ARRAY CHIPS FOR THE DETECTION OF HEAVY METALS IN WATER POLLUTION
    Zhao, Hui-Xin
    Cai, Wei
    Ha, Da
    Wan, Hao
    Wang, Ping
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2012, 5 (01)