摘要
Moisture level significantly affects durability of constructions, their thermal performance and quality of indoor air. Since building envelopes are subjected to a moisture gradient, additional ventilation systems are employed to maintain relative humidity on the desired level. Although modern advanced ventilation systems provide sufficient air exchange rate, their wider application is in conflict with sustainability development principles due to high energy demands. Moreover, according to the European legislation related to the Nearly Zero Energy Buildings (European Directives 2002/91/EC and 2010/31/EU), air tightness of building envelopes in order to provide high thermal resistance leads to large moisture loads in building interiors. Among other factors, a high level of relative humidity has negative effect on the work efficiency and health of building inhabitants. A detailed insight into building materials behavior during cyclic moisture loading was accessed within this study. The moisture buffering values of three interior plasters were investigated in order to describe influence of plasters on moderation of indoor environment. Particular materials were loaded according to the NORDTEST protocol by 8/16 h loading schema at 70/30% RH. Here, the excellent moisture buffer classification was obtained for lightweight perlite plaster (PT) with the highest total open porosity. However, contrary to the higher total open porosity of renovation plaster (PS), the core plaster (CP) achieved higher moisture buffer capacity than PS. This discrepancy refers to the influence of the pore size distribution which is, besides the total open porosity, essential for a detailed characterization of moisture buffering potential of building materials. Based on the results of Mercury intrusion porosimetry, a correlation between pore size distribution and moisture buffer value was revealed.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] POTENTIAL FOR IMPROVED ENERGY EFFICIENCY IN EXISTING OFFICE BUILDINGS.
    Barnes, J.V.
    Enga, T.G.
    Wright, G.F.
    International Journal of Ambient Energy, 1987, 8 (04): : 193 - 206
  • [22] Moisture buffering, energy potential, and volatile organic compound emissions of wood exposed to indoor environments
    Nore, Kristine
    Nyrud, Anders Q.
    Kraniotis, Dimitrios
    Skulberg, Knut R.
    Englund, Finn
    Aurlien, Tormod
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2017, 23 (03) : 512 - 521
  • [23] Energy efficiency of buildings
    Pušnik, Igor
    Elektrotehniski Vestnik/Electrotechnical Review, 2007, 74 (05): : 248 - 254
  • [24] Energy efficiency in buildings
    Lawrence, J.E.
    Energy World, 1988, (163): : 7 - 8
  • [25] Energy efficiency in buildings
    Vrancic, Tanja
    GRADEVINAR, 2012, 64 (02): : 175 - 175
  • [26] Energy efficiency of buildings
    Pusnik, Igor
    ELEKTROTEHNISKI VESTNIK-ELECTROCHEMICAL REVIEW, 2007, 74 (05): : 248 - 254
  • [27] ENERGY EFFICIENCY OF BUILDINGS
    Pana, Adrian
    Dobrin, Cosmin
    Popa, Cristina
    METALURGIA INTERNATIONAL, 2009, 14 : 122 - 124
  • [28] EFFECT OF MOISTURE ON THE ENERGY CONSUMPTION OF BUILDINGS
    Leila, Remache
    Djermane, Nacerddine
    PROCEEDINGS OF SEBUA-12 ICHMT INTERNATIONAL SYMPOSIUM ON SUSTAINABLE ENERGY IN BUILDINGS AND URBAN AREAS, 2012,
  • [29] The different effect of two paint systems on moisture buffer capacity of traditional and modern plasters
    Ranesi, Alessandra
    Veiga, Rosario
    Rodrigues, Paula
    Faria, Paulina
    JOURNAL OF BUILDING ENGINEERING, 2024, 91
  • [30] The energy conundrum of modern buildings
    Mark Bomberg
    Fred Andreas
    Frontiers of Architectural Research, 2013, 2 (04) : 500 - 502