Various applications of immobilized glucose oxidase and polyphenol oxidase in a conducting polymer matrix

被引:23
|
作者
Cil, M.
Boyukbayram, A. E.
Kiralp, S.
Toppare, L. [1 ]
Yagci, Y.
机构
[1] Middle E Tech Univ, Dept Chem, TR-06531 Ankara, Turkey
[2] Istanbul Tech Univ, Dept Chem, TR-80626 Istanbul, Turkey
关键词
electrochemical polymerization; glucose oxidase; polyphenol oxidase;
D O I
10.1016/j.ijbiomac.2006.12.005
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this study, glucose oxidase and polyphenol oxidase were immobilized in conducting polymer matrices; polypyrrole and poly(N-(4-(3-thienyl methylene)-oxycarbonyl phenyl) maleimide-co-pyrrole) via electrochemical method. Fourier transform infrared and scanning electron microscope were employed to characterize the copolymer of (N-(4-(3-thienyl methylene)-oxycarbonyl phenyl) maleimide) with pyrrole. Kinetic parameters, maximum reaction rate and Michealis-Menten constant, were determined. Effects of temperature and pH were examined for immobilized enzymes. Also, storage and operational stabilities of enzyme electrodes were investigated. Glucose and polyphenol oxidase enzyme electrodes were used for determination of the glucose amount in orange juices and human serum and phenolic amount in red wines, respectively. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:49 / 55
页数:7
相关论文
共 50 条
  • [21] DEACTIVATION STUDIES OF IMMOBILIZED GLUCOSE OXIDASE
    KRISHNASWAMY, S
    KITTRELL, JR
    BIOTECHNOLOGY AND BIOENGINEERING, 1978, 20 (06) : 821 - 835
  • [22] IMMOBILIZED GLUCOSE-OXIDASE IN THE POTENTIOMETRIC DETECTION OF GLUCOSE
    WINGARD, LB
    CASTNER, JF
    YAO, SJ
    WOLFSON, SK
    DRASH, AL
    LIU, CC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1982, 184 (SEP): : 47 - MICR
  • [23] DETECTION OF GLUCOSE BY USING IMMOBILIZED GLUCOSE-OXIDASE
    MANOCHIOPINIJ, S
    SAPSAMARNWONG, C
    SIRISALI, K
    JOURNAL OF THE SCIENCE SOCIETY OF THAILAND, 1985, 11 (02): : 79 - 91
  • [24] GLUCOSE-OXIDASE IMMOBILIZED WITH POLYURETHANE FOR GLUCOSE SENSING
    PHADKE, RS
    ALVA, S
    GOVIL, G
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 202 : 147 - BIOT
  • [25] EVALUATION OF A PROCEDURE FOR GLUCOSE UTILIZING IMMOBILIZED GLUCOSE OXIDASE
    BROWN, HH
    MEOLA, JM
    SANSUR, M
    LEON, LP
    CLINICAL CHEMISTRY, 1975, 21 (07) : 978 - 978
  • [26] A METHOD FOR MEASURING GLUCOSE OXIDASE-IMMOBILIZED GLUCOSE
    IVANOV, IP
    DANEV, SI
    DIMITROV, DG
    LABORATORNOE DELO, 1991, (10): : 28 - 30
  • [27] IMMOBILIZED GLUCOSE OXIDASE USED TO MEASURE GLUCOSE IN SERUM
    KUNZ, HJ
    STASTNY, M
    CLINICAL CHEMISTRY, 1974, 20 (08) : 1018 - 1022
  • [28] IMMOBILIZED GLUCOSE-OXIDASE IN THE POTENTIOMETRIC DETECTION OF GLUCOSE
    WINGARD, LB
    CASTNER, JF
    YAO, SJ
    WOLFSON, SK
    DRASH, AL
    LIU, CC
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1984, 9 (01) : 95 - 104
  • [29] SIMULTANEOUS IMMOBILIZATION OF GLUCOSE-OXIDASE AND A MEDIATOR IN CONDUCTING POLYMER-FILMS
    IWAKURA, C
    KAJIYA, Y
    YONEYAMA, H
    JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1988, (15) : 1019 - 1020
  • [30] Selenium containing conducting polymer based pyranose oxidase biosensor for glucose detection
    Gokoglan, Tugba Ceren
    Soylemez, Saniye
    Kesik, Melis
    Toksabay, Sinem
    Toppare, Levent
    FOOD CHEMISTRY, 2015, 172 : 219 - 224