Evaluation of the applicability of the bacterial endotoxin test to antibiotic products

被引:16
|
作者
Yamamoto, A
Ochiai, M
Fujiwara, H
Asakawa, S
Ichinohe, K
Kataoka, M
Toyoizumi, H
Horiuchi, Y
机构
[1] Natl Inst Infect Dis, Dept Safety Res Biol, Tokyo 2080011, Japan
[2] Natl Inst Infect Dis, Dept Bacterial & Blood Prod, Tokyo 2080011, Japan
关键词
endotoxin test; antibiotics; LAL; safety quality control;
D O I
10.1006/biol.2000.0251
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fundamental conditions for applying the bacterial endotoxin test to antibiotic products were investigated so as not to affect the level of regulation by the rabbit pyrogen test. According to accuracy evaluation of test methods, the kinetic-turbidimetric and kinetic-colourimetric assays were shown to allow more accurate measurement and, therefore, more sensitive detection of interference to the bacterial endotoxin test than the gel-clot method. In total, 102 antibiotic products were evaluated on their interfering effect to show that the antibiotics could be categorized into three groups depending on intensity of the interference. Although the test was shown to be applicable even to the group showing the strongest interference, it was assumed to be crucial to use appropriate reagents and an accurate test method for avoiding approval of a pyrogenic product. Accordingly, lists of antibiotics are presented to provide limits of concentration for eliminating interference and endotoxin limits for approval to facilitate effective bacterial endotoxin tests. (C) 2000 The International Association for Biologicals.
引用
收藏
页码:155 / 167
页数:13
相关论文
共 50 条
  • [21] EVALUATION OF EPINEPHRINE SKIN TEST AS A BIOLOGICAL ASSAY FOR ENDOTOXIN
    BUCCINO, R
    LINGLEY, J
    ISRAEL, J
    PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1962, 110 (04): : 724 - &
  • [22] Identification and antibiotic susceptibility of bacterial isolates from probiotic products
    Temmerman, R
    Pot, B
    Huys, G
    Swings, J
    INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2003, 81 (01) : 1 - 10
  • [23] Microscopic evaluation of periapical reactions induced by bacterial endotoxin.
    Ferreira, FBA
    Gomes, BPFA
    Garcia, RB
    Gadê-Neto, CR
    Teixeira, F
    Ferraz, CR
    Souza, FJ
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 227 - 227
  • [24] Evaluation research on applicability of rapid iodide migration test
    Song Zijian
    Jiang Linhua
    Chu Hongqiang
    Xiong Chuansheng
    JOURNAL OF WUHAN UNIVERSITY OF TECHNOLOGY-MATERIALS SCIENCE EDITION, 2014, 29 (02): : 329 - 333
  • [25] Evaluation research on applicability of rapid iodide migration test
    Zijian Song
    Linhua Jiang
    Hongqiang Chu
    Chuansheng Xiong
    Journal of Wuhan University of Technology-Mater. Sci. Ed., 2014, 29 : 329 - 333
  • [26] EVALUATION OF THE APPLICABILITY OF THE SEHCAT TEST IN THE INVESTIGATION OF PATIENTS WITH DIARRHEA
    ORHOLM, M
    PEDERSEN, JO
    ARNFRED, T
    RODBRO, P
    THAYSEN, EH
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1988, 23 (01) : 113 - 117
  • [27] EFFECT OF BACTERIAL PRODUCTS ON SYNOVIAL FIBROBLAST FUNCTION - HYPERMETABOLIC CHANGES INDUCED BY ENDOTOXIN
    BUCKINGH.RB
    CASTOR, CW
    JOURNAL OF CLINICAL INVESTIGATION, 1972, 51 (05): : 1186 - &
  • [28] ANTITUMOR-ACTIVITY OF BACTERIAL-ENDOTOXIN AND ITS SUBUNITS IN AN INVITRO TEST
    SOUREK, J
    ORAVEC, C
    FOLIA MICROBIOLOGICA, 1984, 29 (05) : 420 - 420
  • [29] BACTERIAL (ENDOTOXIN) SHOCK
    KANSHINA, NF
    ARKHIV PATOLOGII, 1980, 42 (05) : 71 - 74
  • [30] ENDOTOXIN IN BACTERIAL PERITONITIS
    BEGER, HG
    GOGLER, H
    KRAAS, E
    BITTNER, R
    CHIRURG, 1981, 52 (02): : 81 - 88