Evaluation of a new competitive immunoassay (BioElisa Syphilis) for screening for Treponema pallidum antibodies at various stages of syphilis

被引:24
|
作者
Ebel, A [1 ]
Bachelart, L [1 ]
Alonso, JM [1 ]
机构
[1] WHO, French Natl Reference Ctr Sexually Transmitt Dis, Immunol Unit,Inst Alfred Fournier, Collaborating Ctr Treponematoses,Biol Lab, F-75680 Paris 14, France
关键词
D O I
10.1128/JCM.36.2.358-361.1998
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The BioElisa Syphilis, a new competitive enzyme immunoassay (EIA) for Treponema pallidum whole antigen that uses specific human immunoglobulin G (IgG) antibodies as the competitor, was evaluated for potential use in screening for syphilis at various stages, The results obtained by this competitive EIA were compared with those obtained by the fluorescent treponemal antibody absorption (FTA-abs) test and the T. pallidum hemagglutination assay (TPHA), Serum samples from 434 patients with positive TPHA and FTA-abs test results, including patients with primary, latent, secondary, and tertiary syphilis and neurosyphilis, were investigated, Two samples tested negative by competitive ELA but were weakly reactive by the TPHA and the FTA-abs test, Sixteen serum samples from patients with clinically documented active syphilis, including several patients infected with human immunodeficiency virus, tested positive by the competitive EIA, There was a direct inverse correlation between EIA indices and titers in the TPHA and the FTA-abs test for all samples that tested positive, Specificity was assessed by testing 358 serum samples which tested negative for syphilis by TPHA and the FTA-abs test, including 100 serum samples from patients with documented infectious or autoimmune diseases, Only two serum samples gave a weakly positive EIA result, Thus, competitive EIA. had a sensitivity of 99.5% and a specificity of 99.4% relative to the results of the FTA-abs test and TPHA, Our evaluation shows that BioElisa Syphilis is a sensitive, specific, and simple assay for screening for syphilis.
引用
收藏
页码:358 / 361
页数:4
相关论文
共 50 条
  • [41] Validation of the INNO-LIA syphilis kit as a confirmatory assay for Treponema pallidum antibodies
    Ebel, A
    Vanneste, L
    Cardinaels, M
    Sablon, E
    Samson, I
    De Bosschere, K
    Hulstaert, F
    Zrein, M
    JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (01) : 215 - 219
  • [42] ANTIGENS OF TREPONEMA-PALLIDUM RECOGNIZED BY IGG AND IGM ANTIBODIES DURING SYPHILIS IN HUMANS
    BAKERZANDER, SA
    HOOK, EW
    BONIN, P
    HANDSFIELD, HH
    LUKEHART, SA
    JOURNAL OF INFECTIOUS DISEASES, 1985, 151 (02): : 264 - 272
  • [43] Evaluation of the Recombinant Protein TpF1 of Treponema pallidum for Serodiagnosis of Syphilis
    Jiang, Chuanhao
    Zhao, Feijun
    Xiao, Jinhong
    Zeng, Tiebing
    Yu, Jian
    Ma, Xiaohua
    Wu, Haiying
    Wu, Yimou
    CLINICAL AND VACCINE IMMUNOLOGY, 2013, 20 (10) : 1563 - 1568
  • [44] EVALUATION OF A TREPONEMA-PALLIDUM WESTERN IMMUNOBLOT ASSAY AS A CONFIRMATORY TEST FOR SYPHILIS
    BYRNE, RE
    LASKA, S
    BELL, M
    LARSON, D
    PHILLIPS, J
    TODD, J
    JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (01) : 115 - 122
  • [45] PERFORMANCE CHARACTERISTICS OF BIOPLEX 2200 SYPHILIS IGG AND LIAISON TREPONEMA AUTOMATED ASSAYS FOR DETECTION OF ANTIBODIES TO TREPONEMA PALLIDUM
    Fakile, Y.
    Kikkert, S.
    Ballard, R.
    Cox, D.
    SEXUALLY TRANSMITTED INFECTIONS, 2011, 87 : A70 - A70
  • [46] Evaluation of an enzyme immunoassay technique for detection of antibodies against Treponema pallidum
    Castro, R
    Prieto, ES
    Santo, I
    Azevedo, J
    Exposto, FD
    JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (01) : 250 - 253
  • [47] Evaluation of a New Recombinant Antigen-Based Virotech Treponema Pallidum Screen ELISA for Diagnosis of Syphilis
    Busse, Clemens
    Navid, Mojdeh Heidary
    Strubel, Andreas
    Schnitzler, Paul
    CLINICAL LABORATORY, 2013, 59 (5-6) : 523 - 529
  • [48] Comparison of a recombinant-antigen enzyme immunoassay with Treponema pallidum hemagglutination test for serological confirmation of syphilis
    Rodríguez, I
    Alvarez, EL
    Fernández, C
    Miranda, A
    MEMORIAS DO INSTITUTO OSWALDO CRUZ, 2002, 97 (03): : 347 - 349
  • [49] Evaluation of two automated chemiluminescence immunoassays, the LIAISON Treponema Screen and the ARCHITECT Syphilis TP, and the Treponema pallidum particle agglutination test for laboratory diagnosis of syphilis
    Wellinghausen, Nele
    Dietenberger, Hanna
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (08) : 1375 - 1377
  • [50] EXPERIMENTAL SYPHILIS IN CHIMPANZEE IMMUNOGLOBULIN-CLASS-OF-EARLY-ANTIBODIES-REACTIVE-WITH TREPONEMA-PALLIDUM
    BROWN, WJ
    KUHN, USG
    TOLLIVER, EA
    NORINS, LC
    BRITISH JOURNAL OF VENEREAL DISEASES, 1970, 46 (03): : 198 - &