Optimization analysis of partially coherent illumination for refractive index tomographic microscopy

被引:10
|
作者
Li, Jiaji [1 ,2 ,3 ]
Zhou, Ning [1 ,2 ,3 ]
Bai, Zhidong [1 ,2 ,3 ]
Zhou, Shun [1 ,2 ,3 ]
Chen, Qian [1 ,2 ]
Zuo, Chao [1 ,2 ]
机构
[1] Nanjing Univ Sci & Technol, Sch Elect & Opt Engn, 200 Xiaolingwei St, Nanjing 210094, Jiangsu, Peoples R China
[2] Nanjing Univ Sci & Technol, Jiangsu Key Lab Spectral Imaging & Intelligent Se, Nanjing 210094, Jiangsu, Peoples R China
[3] Nanjing Univ Sci & Technol, Smart Computat Imaging Lab SCILab, Nanjing 210094, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Computational microscopy; Three-dimensional imaging; Diffraction tomography; Signal processing; OPTICAL DIFFRACTION TOMOGRAPHY; HIGH-THROUGHPUT; BLOOD-CELLS; PHASE; TRANSPORT; DYNAMICS; EQUATION; FIELD;
D O I
10.1016/j.optlaseng.2021.106624
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Partially coherent optical diffraction tomography (PC-ODT) is a well-established label-free quantitative threedimensional (3D) imaging technique based on the refractive index (RI) contrast by measuring the intensities at multiple axially displaced planes. The imaging performance of tomographic RI microscopy is determined by the inversion of phase optical transfer function (POTF) which depends on the illumination pattern of imaging system. Here, we propose the optimization analysis of illumination pattern in PC-ODT, and the custom-build quantitative criterion is demonstrated to maximize the performance of POTF related to the "goodness" evaluation of an illumination aperture. Source modulation with different segment scale and gray scale is implemented to acquire arbitrary distribution source, and the corresponding 3D POTF can be easy obtained through the numerical incoherent superposition of each segment components. Moreover, the metrics of 3D POTF for various illuminations over the condenser aperture are analyzed. We test the obtained optimal illumination by imaging both a simulated micro phase bead and a real control bead sample, suggesting superior performance over other suboptimal patterns in terms of both SNR and spatial resolution. Further, experimental result based on unstained MCF-7 cell clusters is presented support this finding as well, and the proposed method is expected to find versatile applications in biological and biomedical research.
引用
收藏
页数:16
相关论文
共 50 条
  • [11] Binary mask optimization for inverse lithography with partially coherent illumination
    Ma, Xu
    Arce, Gonzalo
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2008, 25 (12) : 2960 - 2970
  • [12] HOLOGRAPHY WITH PARTIALLY COHERENT ILLUMINATION
    MIRANDE, W
    WEINGART.I
    PHYSICS LETTERS A, 1969, A 28 (09) : 623 - &
  • [13] Diffraction phase microscopy with transmission and reflection illumination for refractive index measurements
    Talaikova, N. A.
    Kalyanov, A. L.
    Ryabukho, V. P.
    OPTICAL METHODS FOR INSPECTION, CHARACTERIZATION, AND IMAGING OF BIOMATERIALS II, 2015, 9529
  • [15] Partially coherent illumination in full-field interferometric synthetic aperture microscopy
    Marks, Daniel L.
    Davis, Brynmor J.
    Boppart, Stephen A.
    Carney, P. Scott
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2009, 26 (02) : 376 - 386
  • [16] Numerical focusing in digital holographic microscopy with partially spatially coherent illumination in transmission
    Grebenyuk, Anton A.
    Ryabukho, Vladimir P.
    SARATOV FALL MEETING 2013: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE XV; AND LASER PHYSICS AND PHOTONICS XV, 2014, 9031
  • [17] Partially Coherent Illumination-Based Digital Holographic Microscopy and Its Applications
    Wang Yang
    Zhang Meiling
    Wang Yu
    Wen Kai
    Zhuo Kequn
    Guo Rongli
    Gao Peng
    LASER & OPTOELECTRONICS PROGRESS, 2021, 58 (18)
  • [18] Analysis of EUVL mask effects under partially coherent illumination
    Domnenko, Vitaliy
    Schmoeller, Thomas
    Klimpel, Thomas
    ALTERNATIVE LITHOGRAPHIC TECHNOLOGIES, 2009, 7271
  • [19] Perturbative analysis of partially coherent illumination for coma aberration measurements
    Yashiki, Satoshi
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2015, 32 (04) : 669 - 677
  • [20] FOURIER HOLOGRAPHY WITH PARTIALLY COHERENT ILLUMINATION
    MIRANDE, W
    WEINGARTNER, I
    MENZEL, E
    OPTIK, 1969, 29 (05): : 537 - +