Optimization analysis of partially coherent illumination for refractive index tomographic microscopy

被引:10
|
作者
Li, Jiaji [1 ,2 ,3 ]
Zhou, Ning [1 ,2 ,3 ]
Bai, Zhidong [1 ,2 ,3 ]
Zhou, Shun [1 ,2 ,3 ]
Chen, Qian [1 ,2 ]
Zuo, Chao [1 ,2 ]
机构
[1] Nanjing Univ Sci & Technol, Sch Elect & Opt Engn, 200 Xiaolingwei St, Nanjing 210094, Jiangsu, Peoples R China
[2] Nanjing Univ Sci & Technol, Jiangsu Key Lab Spectral Imaging & Intelligent Se, Nanjing 210094, Jiangsu, Peoples R China
[3] Nanjing Univ Sci & Technol, Smart Computat Imaging Lab SCILab, Nanjing 210094, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Computational microscopy; Three-dimensional imaging; Diffraction tomography; Signal processing; OPTICAL DIFFRACTION TOMOGRAPHY; HIGH-THROUGHPUT; BLOOD-CELLS; PHASE; TRANSPORT; DYNAMICS; EQUATION; FIELD;
D O I
10.1016/j.optlaseng.2021.106624
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Partially coherent optical diffraction tomography (PC-ODT) is a well-established label-free quantitative threedimensional (3D) imaging technique based on the refractive index (RI) contrast by measuring the intensities at multiple axially displaced planes. The imaging performance of tomographic RI microscopy is determined by the inversion of phase optical transfer function (POTF) which depends on the illumination pattern of imaging system. Here, we propose the optimization analysis of illumination pattern in PC-ODT, and the custom-build quantitative criterion is demonstrated to maximize the performance of POTF related to the "goodness" evaluation of an illumination aperture. Source modulation with different segment scale and gray scale is implemented to acquire arbitrary distribution source, and the corresponding 3D POTF can be easy obtained through the numerical incoherent superposition of each segment components. Moreover, the metrics of 3D POTF for various illuminations over the condenser aperture are analyzed. We test the obtained optimal illumination by imaging both a simulated micro phase bead and a real control bead sample, suggesting superior performance over other suboptimal patterns in terms of both SNR and spatial resolution. Further, experimental result based on unstained MCF-7 cell clusters is presented support this finding as well, and the proposed method is expected to find versatile applications in biological and biomedical research.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Partially coherent illumination engineering for enhanced refractive index tomography
    Soto, Juan M.
    Rodrigo, Jost A.
    Alieva, Tatiana
    OPTICS LETTERS, 2018, 43 (19) : 4699 - 4702
  • [2] Partially coherent lensfree tomographic microscopy [Invited]
    Isikman, Serhan O.
    Bishara, Waheb
    Ozcan, Aydogan
    APPLIED OPTICS, 2011, 50 (34) : H253 - H264
  • [3] Structured illumination microscopy with partially coherent illumination for phase and fluorescent imaging
    Wen, Kai
    Gao, ZhaoLin
    Fang, Xiang
    Liu, Min
    Zheng, JuanJuan
    Ma, Ying
    Zalevsky, Zeev
    Gao, Peng
    OPTICS EXPRESS, 2021, 29 (21) : 33679 - 33693
  • [4] BORDER IMAGES IN PARTIALLY COHERENT ILLUMINATION IN CONTRAST MICROSCOPY
    MONDAL, PK
    SLANSKY, S
    OPTICA ACTA, 1970, 17 (06): : 425 - &
  • [5] Spatially multiplexed interferometric microscopy with partially coherent illumination
    Picazo-Bueno, Jose Angel
    Zalevsky, Zeev
    Garcia, Javier
    Ferreira, Carlos
    Mico, Vicente
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (10)
  • [6] Label-free bioanalysis of Leishmania infantum using refractive index tomography with partially coherent illumination
    Soto, Juan M.
    Mas, Alicia
    Rodrigo, Jose A.
    Alieva, Tatiana
    Dominguez-Bernal, Gustavo
    JOURNAL OF BIOPHOTONICS, 2019, 12 (09)
  • [7] Topology optimization for optical microlithography with partially coherent illumination
    Zhou, Mingdong
    Lazarov, Boyan S.
    Sigmund, Ole
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2017, 109 (05) : 631 - 647
  • [8] Quantitative Phase Contrast Microscopy with Optimized Partially Coherent Illumination
    Zhuo, Kequn
    Wang, Yang
    Ma, Ying
    An, Sha
    Zalevsky, Zeev
    Zheng, Juanjuan
    Gao, Peng
    PHOTONICS, 2023, 10 (04)
  • [9] Experimental analysis and designing strategies of lens-less microscopy with partially coherent illumination
    Bian, Yinxu
    Wang, Wensheng
    Hussian, Anwar
    Kuang, Cuifang
    Li, Haifeng
    Liu, Xu
    OPTICS COMMUNICATIONS, 2019, 434 : 136 - 144
  • [10] Binary Mask Optimization for Inverse Lithography with Partially Coherent Illumination
    Ma, Xu
    Arce, Gonzalo R.
    LITHOGRAPHY ASIA 2008, 2008, 7140