Reduction in spread of excitation from current focusing at multiple cochlear locations in cochlear implant users

被引:36
|
作者
Padilla, Monica [1 ,2 ,3 ]
Landsberger, David M. [1 ,2 ]
机构
[1] House Res Inst, Dept Commun & Neurosci, 2100 West 3rd St, Los Angeles, CA 90057 USA
[2] NYU, Sch Med, Dept Otolaryngol, 550 1st Ave STE NBV 5E5, New York, NY 10016 USA
[3] Univ So Calif, Keck Sch Med, Dept Otolaryngol, 806 W Adams Blvd, Los Angeles, CA 90007 USA
关键词
Cochlear; Implants; Tripolar; Spread; Scaling; VIRTUAL CHANNEL DISCRIMINATION; ELECTRODE CONFIGURATION; TRIPOLAR STIMULATION; PLACE SPECIFICITY; MONOPOLAR; MASKING; PATTERNS; NOISE;
D O I
10.1016/j.heares.2016.01.002
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Channel interaction from a broad spread of excitation is likely to be a limiting factor in performance by cochlear implant users. Although partial tripolar stimulation has been shown to reduce spread of excitation, the magnitude of the reduction is highly variable across subjects. Because the reduction in spread of excitation is typically only measured at one electrode for a given subject, the degree of variability across cochlear locations is unknown. The first goal of the present study was to determine if the reduction in spread of excitation observed from partial tripolar current focusing systematically varies across the cochlea. The second goal was to measure the variability in reduction of spread of excitation relative to monopolar stimulation across the cochlea. The third goal was to expand upon previous results that suggest that scaling of verbal descriptors can be used to predict the reduction in spread of excitation, by increasing the limited number of sites previously evaluated and verify the relationships remain with the larger dataset. The spread of excitation for monopolar and partial tripolar stimulation was measured at 5 cochlear locations using a psychophysical forward masking task. Results of the present study suggest that although partial tripolar stimulation typically reduces spread of excitation, the degree of reduction in spread of excitation was found to be highly variable and no effect of cochlear location was found. Additionally, subjective scaling of certain verbal descriptors (Clean/Dirty, Pure/Noisy) correlated with the reduction in spread of excitation suggesting sound quality scaling might be used as a quick clinical estimate of channels providing a reduction in spread of excitation. This quick scaling technique might help clinicians determine which patients would be most likely to benefit from a focused strategy. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:98 / 107
页数:10
相关论文
共 50 条
  • [31] Audiovisual Segregation in Cochlear Implant Users
    Landry, Simon
    Bacon, Benoit A.
    Leybaert, Jacqueline
    Gagne, Jean-Pierre
    Champoux, Francois
    PLOS ONE, 2012, 7 (03):
  • [32] Speaker discrimination in cochlear implant users
    Muehler, R.
    Ziese, M.
    Verhey, J. L.
    HNO, 2017, 65 (03) : 243 - 249
  • [33] Virtual channel discrimination is improved by current focusing in cochlear implant recipients
    Landsberger, David M.
    Srinivasan, Arthi G.
    HEARING RESEARCH, 2009, 254 (1-2) : 34 - 41
  • [34] Influence of the Cochlear Implant Electrode Array Placement on the Current Spread in the Cochlea
    Schaefer, Friederike
    Enke, Joerg
    Boehnke, Frank
    Hemmert, Werner
    Bai, Siwei
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 6145 - 6148
  • [35] Auditory perception in pediatric cochlear implant users with cochlear nerve hypoplasia
    Uzun, Erva Degirmenci
    Batuk, Merve Ozbal
    D'Alessandrob, Hilal Dincer
    Sennaroglu, Gonca
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2022, 160
  • [36] Cochlear Blood Flow and Speech Perception Ability in Cochlear Implant Users
    Nakashima, Tsutomu
    Hattori, Taku
    Sone, Michihiko
    Asahi, Kiyomitsu
    Matsuda, Naoko
    Teranishi, Masaaki
    Yoshida, Tadao
    Kato, Ken
    Sato, Eisuke
    OTOLOGY & NEUROTOLOGY, 2012, 33 (02) : 165 - 168
  • [37] Personalizing Transient Noise Reduction Algorithm Settings for Cochlear Implant Users
    Stronks, H. Christiaan
    Tops, Annemijn L.
    Hehrmann, Phillipp
    Briaire, Jeroen J.
    Frijns, Johan H. M.
    EAR AND HEARING, 2021, 42 (06): : 1602 - 1614
  • [38] COCHLEAR IMPLANT - CURRENT STATUS
    HOUSE, WF
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1975, 84 (04): : 493 - 493
  • [39] The impact of cochlear implants from the perspective of significant others of adult cochlear implant users: In reply
    Kennedy, Veronica
    OTOLOGY & NEUROTOLOGY, 2008, 29 (05) : 734 - 734
  • [40] MULTIPLE ELECTRODE COCHLEAR IMPLANT
    CLARK, GM
    TONG, YC
    BLACK, R
    FORSTER, IC
    PATRICK, JF
    DEWHURST, DJ
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1977, 91 (11): : 935 - 945