Assessing accuracy of a continuous screening test in the presence of verification bias

被引:57
|
作者
Alonzo, TA
Pepe, MS
机构
[1] Univ So Calif, Keck Sch Med, Arcadia, CA 91066 USA
[2] Univ Washington, Seattle, WA 98195 USA
关键词
area under the curve; imputation; inverse probability weighting; mean score; neonatal hearing screening; receiver operating characteristic curve; semiparametric estimators; sensitivity; specificity;
D O I
10.1111/j.1467-9876.2005.00477.x
中图分类号
O21 [概率论与数理统计]; C8 [统计学];
学科分类号
020208 ; 070103 ; 0714 ;
摘要
In studies to assess the accuracy of a screening test, often definitive disease assessment is too invasive or expensive to be ascertained on all the study subjects. Although it may be more ethical or cost effective to ascertain the true disease status with a higher rate in study subjects where the screening test or additional information is suggestive of disease, estimates of accuracy can be biased in a study with such a design. This bias is known as verification bias. Verification bias correction methods that accommodate screening tests with binary or ordinal responses have been developed; however, no verification bias correction methods exist for tests with continuous results. We propose and compare imputation and reweighting bias-corrected estimators of true and false positive rates, receiver operating characteristic curves and area under the receiver operating characteristic curve for continuous tests. Distribution theory and simulation studies are used to compare the proposed estimators with respect to bias, relative efficiency and robustness to model misspecification. The bias correction estimators proposed are applied to data from a study of screening tests for neonatal hearing loss.
引用
收藏
页码:173 / 190
页数:18
相关论文
共 50 条
  • [41] Understanding the Direction of Bias in Studies of Diagnostic Test Accuracy
    Kohn, Michael A.
    Carpenter, Christopher R.
    Newman, Thomas B.
    [J]. ACADEMIC EMERGENCY MEDICINE, 2013, 20 (11) : 1194 - 1206
  • [42] ASSESSING SCREENING EFFICACY IN THE PRESENCE OF CANCER OVERDIAGNOSIS
    Huanga, Ying
    Fengb, Ziding
    [J]. ANNALS OF APPLIED STATISTICS, 2024, 18 (02): : 1543 - 1564
  • [43] THE IMPACT OF SELECTION BIAS ON MEASUREMENT OF NONINVASIVE TEST ACCURACY
    SALERNO, DM
    WANG, K
    GOLDENBERG, IF
    VANTASSEL, RA
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (02): : 223 - 225
  • [44] PARTIAL VERIFICATION-A COMMON SOURCE OF BIAS IN DIAGNOSTIC ACCURACY STUDIES
    Schmidt, Robert L.
    Cohen, Michael B.
    [J]. ENDOCRINE PRACTICE, 2015, 21 (02) : 211 - 211
  • [45] ADJUSTING FOR DIFFERENTIAL VERIFICATION BIAS IN DIAGNOSTIC ACCURACY STUDIES: A BAYESIAN APPROACH
    de Groot, J. A. H.
    Dendukuri, N.
    Janssen, K. J. M.
    Reitsma, J.
    Bossuyt, P. M.
    Moons, K. G. M.
    [J]. AMERICAN JOURNAL OF EPIDEMIOLOGY, 2010, 171 : S140 - S140
  • [46] Researchers should be aware of partial verification bias in diagnostic accuracy studies
    Schmidt, Robert L.
    Factor, Rachel E.
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2015, 119 (05): : 593 - 593
  • [47] The bias of dark matter tracers: assessing the accuracy of mapping techniques
    Pellejero-Ibanez, M.
    Balaguera-Antolinez, A.
    Kitaura, Francisco-Shu
    Angulo, Raul E.
    Yepes, Gustavo
    Chuang, Chia-Hsun
    Reyes-Peraza, Guillermo
    Autefage, Mathieu
    Vakili, Mohammadjavad
    Zhao, Cheng
    [J]. MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2020, 493 (01) : 586 - 593
  • [48] Floating denominators - effect of verification bias on accuracy estimates for preimplantation diagnosis
    Platteau, P
    Staessen, C
    Liebaers, I
    Van Steirteghem, A
    Devroey, P
    [J]. FERTILITY AND STERILITY, 2003, 79 (04) : 1041 - 1042
  • [49] Assessing accuracy in close relationships research: A truth and bias approach
    Stern, Chadly
    West, Tessa V.
    [J]. JOURNAL OF SOCIAL AND PERSONAL RELATIONSHIPS, 2018, 35 (01) : 89 - 111
  • [50] Nonparametric verification bias-corrected inference for the area under the ROC curve of a continuous-scale diagnostic test
    Adimari, Gianfranco
    Chiogna, Monica
    [J]. STATISTICS AND ITS INTERFACE, 2017, 10 (04) : 629 - 641